FabDigitFabDigit

Stainless Steel CG3M HIP+SA

Heat-treated state

ASTM CG3M · UNS J92999 · EN 1.4508

Chosen for pressure-critical pump/valve castings where shrinkage porosity must be closed for higher fatigue life and better radiographic quality.

Premium cost $$$

Values for the HIP+SA condition

Other CG3M tempers and conditions

CG3M is listed in 3 conditions; see the grade overview at CG3M.

Compare all 3 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
SADefault
Solution annealed
Standard supply condition for ASTM A743/A744 CG3M castings; maximum corrosion resistance and ductility.27553040150 HB—
Spheroidize annealed
Only for non-critical, non-corrosive duty; residual segregation and interdendritic phases lower corrosion resistance and toughness versus solution annealed.28552028160 HB2.1 % IACS
HIP+SAThis page
hot isostatically pressed then solution annealed
Chosen for pressure-critical pump/valve castings where shrinkage porosity must be closed for higher fatigue life and better radiographic quality.28555045150 HB2.1 % IACS

What is CG3M HIP+SA?

CG3M HIP+SA is CG3M heat treated to HIP+SA — chosen for pressure-critical pump/valve castings where shrinkage porosity must be closed for higher fatigue life and better radiographic quality. CG3M HIP+SA has a yield strength of 285 MPa (41.3 ksi) and a tensile strength of 550 MPa (79.8 ksi) — weaker than 74% of stainless steel grades. Elongation at break is 45% and the elastic modulus is 193 GPa (28 Msi). CG3M HIP+SA has a density of 7.98 g/cm³ (0.288 lb/in³), heavier than 85% of stainless steel grades. It melts at 1,400°C (2,552 °F). SA is the default condition FabDigit quotes; HIP+SA is available on request or by drawing note.

Advantages

  • Readily welded — 85/100, better than 87% of stainless steel grades
  • Good corrosion resistance — 76/100, better than 80% of stainless steel grades
  • Ductile — tolerates forming and impact — 45%, better than 76% of stainless steel grades

Limitations

  • Hard to polish — 60/100, worse than 80% of stainless steel grades
  • Limited formability — 25/100, worse than 78% of stainless steel grades

CG3M HIP+SA properties

Typical room-temperature values for CG3M HIP+SA; 22 are specific to this condition. Other listed values are CG3M reference data and may not represent this condition. Bars are the position among stainless steel grades.

Physical3

CG3M HIP+SA has a density of 7.98 g/cm³ (0.288 lb/in³), heavier than 85% of stainless steel grades. It melts at 1,400°C (2,552 °F).

Density7.98 g/cm³0.29 lb/in³
Melting Point (Solidus)1,400°C2,552 °F
Liquidus Temperature1,450°C2,642 °F

Mechanical14

CG3M HIP+SA has a yield strength of 285 MPa (41.3 ksi) and a tensile strength of 550 MPa (79.8 ksi) — weaker than 74% of stainless steel grades. Elongation at break is 45% and the elastic modulus is 193 GPa (28 Msi).

Elastic (Young's) Modulus193 GPa28 Msi
Shear Modulus77 GPa11.2 Msi
Bulk Modulus160 GPa23.2 Msi
Poisson's Ratio0.3
Tensile Strength (Ultimate)550 MPa79.8 ksi
Yield Strength (0.2% offset)285 MPa41.3 ksi
Elongation at Break45%
Reduction in Area60%
Shear Strength385 MPa55.8 ksi
Fatigue Strength (Endurance Limit)250 MPa36.3 ksi
Fracture Toughness (K_IC)180 MPa·√m164 ksi·√in
Charpy V-Notch Impact (RT)120 J88.5 ft·lbf
Hardness, Brinell150 HB
Hardness, Rockwell B80 HRB

Thermal6

CG3M HIP+SA is rated for continuous service to 425°C (797 °F). It conducts heat at 14.5 W/m·K (8.38 BTU/hr·ft·°F), worse than 72% of stainless steel grades. Thermal expansion is 16.2 µm/m·K (9 µin/in·°F).

Thermal Conductivity14.5 W/m·K8.4 BTU/hr·ft·°F
Specific Heat Capacity500 J/kg·K0.12 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)16.2 µm/m·K9 µin/in·°F
Latent Heat of Fusion270 J/g116 BTU/lb
Max Service Temperature (continuous)425°C797 °F
Min Service Temperature-196°C-321 °F

Electrical3

CG3M HIP+SA conducts electricity at 2.1 % IACS, worse than 73% of stainless steel grades.

Electrical Conductivity2.1 % IACS
Electrical Resistivity8.2×10⁻⁷ Ω·m32.3 µΩ·in
Magnetic Responseweakly magnetic

Chemical & Environmental3

Corrosion resistance is very good (76/100), better than 80% of stainless steel grades.

Galvanic Potential (seawater, vs SCE)-0.1 V
Corrosion ResistanceVery good76/100
Chemical Resistance SummaryVery good in dilute sulfuric, sulfite/pulp bleach and phosphoric solutions and in chloride-bearing water up to moderate temperature; the extra Mo raises pitting/crevice resistance above CF3M, but it is not suitable for hot concentrated chlorides, hydrochloric acid, ferric chloride or strong oxidizing halides.

Sustainability4

Producing a kilogram of CG3M HIP+SA takes about 55 MJ of energy and emits 4.5 kg of CO₂ — more than 50% of stainless steel grades. Typical recycled content is 75%.

Embodied Energy (primary production)55 MJ/kg23,646 BTU/lb
Embodied Carbon (primary production)4.5 kg CO₂/kg
Embodied Water130 L/kg15.6 gal/lb
Typical Recycled Content75%

Manufacturability8

CG3M HIP+SA's machinability is poor (34/100, worse than 55% of stainless steel grades); weldability excellent (85/100); formability poor (25/100).

MachinabilityPoor34/100
Machinability Rating (AISI 1212 = 100 %)36%
WeldabilityExcellent85/100
Formability (cold)Poor25/100
CastabilityVery good70/100
Brazeability / SolderabilityGood55/100
PolishabilityGood60/100
Anodizing Responsen/a — ferrous alloy; passivation (ASTM A967 nitric/citric) or electropolishing is used instead

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with CG3M HIP+SA

Is CG3M easy to machine?

Machine like CF3M/316L cast stainless: rigid setup, sharp positive-rake carbide, low speed with heavy feed, flood coolant and no dwelling to avoid work-hardened glazing.

Can CG3M be welded?

Excellent — GTAW/SMAW with ER316L/E316L-15 (or matching CG3M/ER317L for full Mo match); low carbon means no post-weld solution anneal is needed, keep interpass low and avoid full-ferrite-free deposits to limit hot cracking.

Can CG3M be formed, bent or molded?

Sand or investment cast only; allow ~2.5 % shrinkage with generous risering and chills, then solution anneal and water quench for corrosion service.

What surface finishes work on CG3M?

Grit blast, pickle and passivate per ASTM A967 (citric or nitric); electropolishing gives the best cleanliness for pulp/chemical duty — no anodizing.

CG3M chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
Clow-carbon grade, avoids sensitization≤ 0.030.02
Mn≤ 1.50.8
Si≤ 1.51
P≤ 0.04—
S≤ 0.04—
Cr18 – 2119.5
Ni9 – 1311
Mohigher than CF3M (2–3 %)3 – 43.5
Febalance—

CG3M HIP+SA — frequently asked

What is CG3M HIP+SA used for?

CG3M HIP+SA is typically used for welded chemical process castings, corrosive fluid handling components, pump casings and impellers for acid service, valve bodies and bonnets, pulp bleach plant fittings and scrubber and absorber internals. In short: weldable high-Mo cast austenitic; low-carbon CG8M; better corrosion than CF3M.

What is the yield strength of CG3M HIP+SA?

CG3M HIP+SA has a typical yield strength of 285 MPa (41.3 ksi) and a tensile strength of 550 MPa (79.8 ksi) — weaker than 74% of stainless steel grades. Strength varies by condition: see the 3 listed tempers.

Is CG3M HIP+SA easy to machine?

Not especially — machinability is rated poor (34/100, worse than 55% of stainless steel grades). Machine like CF3M/316L cast stainless: rigid setup, sharp positive-rake carbide, low speed with heavy feed, flood coolant and no dwelling to avoid work-hardened glazing.

Can CG3M HIP+SA be welded?

Yes — weldability is rated excellent (85/100). Excellent — GTAW/SMAW with ER316L/E316L-15 (or matching CG3M/ER317L for full Mo match); low carbon means no post-weld solution anneal is needed, keep interpass low and avoid full-ferrite-free deposits to limit hot cracking.

What surface finishes work on CG3M HIP+SA?

Grit blast, pickle and passivate per ASTM A967 (citric or nitric); electropolishing gives the best cleanliness for pulp/chemical duty — no anodizing.

Can CG3M HIP+SA be formed, bent or molded?

Sand or investment cast only; allow ~2.5 % shrinkage with generous risering and chills, then solution anneal and water quench for corrosion service.

What is the maximum service temperature of CG3M HIP+SA?

CG3M HIP+SA is rated for continuous use to about 425°C (797 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between CG3M-SA and CG3M-AC?

SA is the default condition — standard supply condition for ASTM A743/A744 CG3M castings; maximum corrosion resistance and ductility. AC: only for non-critical, non-corrosive duty; residual segregation and interdendritic phases lower corrosion resistance and toughness versus solution annealed. Yield strength is 275 MPa in SA versus 285 MPa in AC.

Sources

  1. ASTM A743/A743M — Castings, Iron-Chromium, Iron-Chromium-Nickel, Corrosion Resistant, for General Application — ASTM (2019)
  2. ASTM A744/A744M — Castings, Iron-Chromium-Nickel, Corrosion Resistant, for Severe Service — ASTM (2019)
  3. Steel Castings Handbook, Supplement 8 — High Alloy Data Sheets, Corrosion Series — SFSA (2004)
  4. ASM Handbook Vol.1 — Properties and Selection: Irons, Steels, and High-Performance Alloys — ASM International (1990)
  5. ASM Handbook Vol.15 — Casting — ASM International (2008)
  6. UNS J92999 alloy record — SAE/ASTM Unified Numbering System (2018)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.