FabDigitFabDigit

Copper Alloy C91000-M06

Finish state

UNS C91000

M06 = as investment cast

Continuous-cast bar/tube stock for machined bushings — most uniform, lowest porosity, best machined surface.

High cost $$$$

Values for the M06 condition

Other C91000 tempers and conditions

C91000 is listed in 6 conditions; see the grade overview at C91000.

Compare all 6 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
Heat treated
Optional low-temperature soak to relieve casting stresses and even out coring; slightly lowers hardness, improves dimensional stability.1452202125 HB10 % IACS
M01Default
As sand cast
Standard foundry condition for bushings, worm gears and wear plates; most widely stocked/produced form.1502251.5135 HB9 % IACS
As plaster cast
Near-net-shape small intricate wear parts where machining of the hard δ-phase is to be minimised.1502251.5135 HB9 % IACS
As hot forged and air cooled
For repeat-production small parts needing tight dimensions and a chilled, harder wear surface.1602401.5145 HB9 % IACS
As centrifugally cast
Choose for dense, pore-free sleeves and rings; the finer chilled structure raises strength and hardness slightly.1652502140 HB9 % IACS
M06This page
As investment cast
Continuous-cast bar/tube stock for machined bushings — most uniform, lowest porosity, best machined surface.1752653130 HB9 % IACS

What is C91000-M06?

C91000-M06 is C91000 supplied in the M06 condition — continuous-cast bar/tube stock for machined bushings — most uniform, lowest porosity, best machined surface. C91000-M06 has a yield strength of 175 MPa (25.4 ksi) and a tensile strength of 265 MPa (38.4 ksi) — weaker than 60% of copper alloy grades. Elongation at break is 3% and the elastic modulus is 103 GPa (14.9 Msi). C91000-M06 has a density of 8.8 g/cm³ (0.318 lb/in³), heavier than 58% of copper alloy grades. It melts at 830°C (1,526 °F). M01 is the default condition FabDigit quotes; M06 is available on request or by drawing note.

Limitations

  • Limited ductility — 3%, worse than 97% of copper alloy grades
  • Difficult to weld — 15/100, worse than 94% of copper alloy grades
  • Limited formability — 8/100, worse than 94% of copper alloy grades
  • High embodied carbon — 4.6 kg CO₂/kg, worse than 82% of copper alloy grades
  • Low electrical conductivity — 9 % IACS, worse than 78% of copper alloy grades

C91000-M06 properties

Typical room-temperature values for C91000-M06; 21 are specific to this condition. Other listed values are C91000 reference data and may not represent this condition. Bars are the position among copper alloy grades.

Physical3

C91000-M06 has a density of 8.8 g/cm³ (0.318 lb/in³), heavier than 58% of copper alloy grades. It melts at 830°C (1,526 °F).

Density8.8 g/cm³0.32 lb/in³
Melting Point (Solidus)830°C1,526 °F
Liquidus Temperature1,000°C1,832 °F

Mechanical15

C91000-M06 has a yield strength of 175 MPa (25.4 ksi) and a tensile strength of 265 MPa (38.4 ksi) — weaker than 60% of copper alloy grades. Elongation at break is 3% and the elastic modulus is 103 GPa (14.9 Msi).

Elastic (Young's) Modulus103 GPa14.9 Msi
Shear Modulus39 GPa5.7 Msi
Bulk Modulus115 GPa16.7 Msi
Poisson's Ratio0.33
Tensile Strength (Ultimate)265 MPa38.4 ksi
Yield Strength (0.2% offset)175 MPa25.4 ksi
Elongation at Break3%
Reduction in Area3%
Compressive Strength570 MPa82.7 ksi
Shear Strength190 MPa27.6 ksi
Fatigue Strength (Endurance Limit)105 MPa15.2 ksi
Charpy V-Notch Impact (RT)5 J3.7 ft·lbf
Hardness, Brinell130 HB
Hardness, Rockwell B72 HRB
Hardness, Vickers135 HV

Thermal6

C91000-M06 is rated for continuous service to 250°C (482 °F). It conducts heat at 48 W/m·K (27.7 BTU/hr·ft·°F), worse than 67% of copper alloy grades. Thermal expansion is 18 µm/m·K (10 µin/in·°F).

Thermal Conductivity48 W/m·K27.7 BTU/hr·ft·°F
Specific Heat Capacity376 J/kg·K0.09 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)18 µm/m·K10 µin/in·°F
Latent Heat of Fusion175 J/g75.2 BTU/lb
Max Service Temperature (continuous)250°C482 °F
Min Service Temperature-200°C-328 °F

Electrical3

C91000-M06 conducts electricity at 9 % IACS, worse than 78% of copper alloy grades.

Electrical Conductivity9 % IACS
Electrical Resistivity1.9×10⁻⁷ Ω·m7.48 µΩ·in
Magnetic Responsenon-magnetic

Chemical & Environmental3

Corrosion resistance is good (67/100), better than 66% of copper alloy grades.

Galvanic Potential (seawater, vs SCE)-0.26 V
Corrosion ResistanceGood67/100
Chemical Resistance SummaryGood resistance to seawater, fresh water, neutral salts, steam and non-oxidizing acids; attacked by ammonia/amines, nitric acid, ferric and mercuric salts, and sulphur-bearing media.

Sustainability4

Producing a kilogram of C91000-M06 takes about 62 MJ of energy and emits 4.6 kg of CO₂ — more than 76% of copper alloy grades. Typical recycled content is 40%.

Embodied Energy (primary production)62 MJ/kg26,655 BTU/lb
Embodied Carbon (primary production)4.6 kg CO₂/kg
Embodied Water300 L/kg35.9 gal/lb
Typical Recycled Content40%

Manufacturability8

C91000-M06's machinability is fair (35/100, better than 51% of copper alloy grades); weldability poor (15/100); formability not recommended (8/100).

MachinabilityFair35/100
Machinability Rating (AISI 1212 = 100 %)35%
WeldabilityPoor15/100
Formability (cold)Not recommended8/100
CastabilityVery good70/100
Brazeability / SolderabilityGood60/100
PolishabilityVery good70/100
Anodizing Responsen/a — copper alloy; use chemical/mechanical finishing or patination instead

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with C91000-M06

Is C91000 easy to machine?

Machines like a hard, brittle bronze — short chips, use sharp positive-rake carbide, moderate speed and rigid setup; the δ phase is abrasive and dulls HSS quickly.

Can C91000 be welded?

Fusion welding is not recommended (hot-short, cracks readily); repair by brazing or soft soldering, or replace the casting.

Can C91000 be formed, bent or molded?

Cast only — no hot or cold working; pour with adequate risering and chills to limit inverse segregation, gas porosity and shrinkage in the wide freezing range.

What surface finishes work on C91000?

Takes a fine ground/lapped bearing surface and can be polished or chemically patinated; electroplating (Ni, Sn) is possible but rarely needed.

C91000 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
CuCu + named elements ≥ 99.4 %84 – 8685
Snforms hard δ (Cu31Sn8) phase14 – 1615
Zn≤ 1.5—
Pb≤ 0.2—
Nicounted with Co in some listings≤ 0.8—
Fe≤ 0.2—
Sb≤ 0.2—
P≤ 0.05—
S≤ 0.05—
Al≤ 0.01—
Si≤ 0.01—

C91000-M06 — frequently asked

What is C91000-M06 used for?

C91000-M06 is typically used for worm gears, wear rings and sliding parts. In short: hardest common tin bronze; low-speed wear parts; brittle, shock-sensitive casting.

What is the yield strength of C91000-M06?

C91000-M06 has a typical yield strength of 175 MPa (25.4 ksi) and a tensile strength of 265 MPa (38.4 ksi) — weaker than 60% of copper alloy grades. Strength varies by condition: see the 6 listed tempers.

Is C91000-M06 easy to machine?

Not especially — machinability is rated fair (35/100, better than 51% of copper alloy grades). Machines like a hard, brittle bronze — short chips, use sharp positive-rake carbide, moderate speed and rigid setup; the δ phase is abrasive and dulls HSS quickly.

Can C91000-M06 be welded?

Not readily — weldability is rated poor (15/100). Fusion welding is not recommended (hot-short, cracks readily); repair by brazing or soft soldering, or replace the casting.

What surface finishes work on C91000-M06?

Takes a fine ground/lapped bearing surface and can be polished or chemically patinated; electroplating (Ni, Sn) is possible but rarely needed.

Can C91000-M06 be formed, bent or molded?

Cast only — no hot or cold working; pour with adequate risering and chills to limit inverse segregation, gas porosity and shrinkage in the wide freezing range.

What is the maximum service temperature of C91000-M06?

C91000-M06 is rated for continuous use to about 250°C (482 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between C91000-M01 and C91000-M06?

M01 is the default condition — standard foundry condition for bushings, worm gears and wear plates; most widely stocked/produced form. M06: continuous-cast bar/tube stock for machined bushings — most uniform, lowest porosity, best machined surface. Yield strength is 150 MPa in M01 versus 175 MPa in M06.

Sources

  1. Copper Alloy C91000 alloy data sheet — Copper Development Association (copper.org) (2023)
  2. ASM Handbook Vol. 2 — Properties and Selection: Nonferrous Alloys and Special-Purpose Materials (cast tin bronzes) — ASM International (1990)
  3. ASTM B505/B505M — Copper Alloy Continuous Castings — ASTM International (2018)
  4. ASTM B22 — Bronze Castings for Bridges and Turntables — ASTM International (2017)
  5. ASM Handbook Vol. 13B — Corrosion of copper and copper alloys — ASM International (2005)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.