FabDigitFabDigit

Copper Alloy C91000-M01 vs C91000-M06

Copper Alloy · C91000 temper comparison

C91000-M01 and C91000-M06 are two conditions of the same copper alloy grade, C91000: M01 (as sand cast) versus M06 (as investment cast). The chemistry is identical, so every difference below comes from the condition. C91000-M06 is the stronger of the two: yield strength 175 MPa (25.4 ksi) against 150 MPa (21.8 ksi) for C91000-M01, about 17% more; tensile strength follows at 265 MPa (38.4 ksi) vs 225 MPa (32.6 ksi). C91000-M06 is the more ductile: elongation 3% versus 1.5% for C91000-M01.

C91000-M06Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

C91000-M01 vs C91000-M06: properties

C91000-M01C91000-M06

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

225 MPa32.6 ksi
265 MPa38.4 ksi

Yield Strength (0.2% offset)

150 MPa21.8 ksi
175 MPa25.4 ksi

Elongation at Break

1.5%
3%

Reduction in Area

2%
3%

Compressive Strength

550 MPa79.8 ksi
570 MPa82.7 ksi

Shear Strength

170 MPa24.7 ksi
190 MPa27.6 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
105 MPa15.2 ksi

Charpy V-Notch Impact (RT)

3 J2.2 ft·lbf
5 J3.7 ft·lbf

Hardness, Brinell

135 HB
130 HB

Hardness, Rockwell B

75 HRB
72 HRB

Hardness, Vickers

140 HV
135 HV

Same in both: Elastic (Young's) Modulus 103 GPa14.9 Msi · Shear Modulus 39 GPa5.7 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 830°C1,526 °F · Liquidus Temperature 1,000°C1,832 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

47 W/m·K27.2 BTU/hr·ft·°F
48 W/m·K27.7 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 376 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Max Service Temperature (continuous) 250°C482 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9 % IACS · Electrical Resistivity 1.9×10⁻⁷ Ω·m7.48 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

65 / 100
67 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.26 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
35 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
35%

Formability (cold)

5 / 100
8 / 100

Same in both: Weldability 15 / 100 · Castability 70 / 100 · Brazeability / Solderability 60 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC91000

C91000-M01 vs C91000-M06 — frequently asked

Is C91000-M06 stronger than C91000-M01?

Yes. C91000-M06 has a typical yield strength of 175 MPa (25.4 ksi) against 150 MPa (21.8 ksi) for C91000-M01 — about 17% more. Tensile strength is 265 MPa (38.4 ksi) vs 225 MPa (32.6 ksi).

Which condition does FabDigit quote by default, M01 or M06?

M01 is the default C91000 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C91000-M01 or C91000-M06?

C91000-M06. Its machinability rates fair (35/100) against poor (30/100) for C91000-M01.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C91000-M01 and C91000-M06 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.