FabDigitFabDigit

Copper Alloy C84200-M02

Heat-treated state

UNS C84200

M02 = as centrifugally cast

Choose for rings, bushings and flanged sleeves needing a denser, more pressure-tight wall than sand casting.

High cost $$$$

Values for the M02 condition

Other C84200 tempers and conditions

C84200 is listed in 5 conditions; see the grade overview at C84200.

Compare all 5 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
M01Default
As sand cast
Standard as-cast sand casting condition for valve bodies, fittings and general plumbing hardware.1032412755 HB16.4 % IACS
As investment cast
Investment-cast condition for small complex near-net-shape parts with tight tolerances.1032412555 HB16.4 % IACS
M02This page
As centrifugally cast
Choose for rings, bushings and flanged sleeves needing a denser, more pressure-tight wall than sand casting.1102552558 HB16.4 % IACS
As plaster cast
For higher-volume small fittings where finer chill structure gives slightly higher strength and better surface.1102552458 HB16.4 % IACS
As continuous cast
Continuous-cast bar/tube stock — densest, most uniform structure and the best choice for machined-from-solid fittings.1242622060 HB16.4 % IACS

What is C84200-M02?

C84200-M02 is C84200 heat treated to M02 — choose for rings, bushings and flanged sleeves needing a denser, more pressure-tight wall than sand casting. C84200-M02 has a yield strength of 110 MPa (16 ksi) and a tensile strength of 255 MPa (37 ksi) — weaker than 82% of copper alloy grades. Elongation at break is 25% and the elastic modulus is 95 GPa (13.8 Msi). C84200-M02 has a density of 8.6 g/cm³ (0.311 lb/in³), lighter than 59% of copper alloy grades. It melts at 843°C (1,549 °F). M01 is the default condition FabDigit quotes; M02 is available on request or by drawing note.

Advantages

  • Easy to machine — 80/100, better than 86% of copper alloy grades

Limitations

  • Low stiffness — 95 GPa (13.8 Msi), worse than 93% of copper alloy grades
  • Difficult to weld — 20/100, worse than 88% of copper alloy grades
  • Hard to polish — 65/100, worse than 87% of copper alloy grades
  • Low strength — 110 MPa (16 ksi), worse than 82% of copper alloy grades
  • Limited formability — 15/100, worse than 79% of copper alloy grades

C84200-M02 properties

Typical room-temperature values for C84200-M02; 19 are specific to this condition. Other listed values are C84200 reference data and may not represent this condition. Bars are the position among copper alloy grades.

Physical3

C84200-M02 has a density of 8.6 g/cm³ (0.311 lb/in³), lighter than 59% of copper alloy grades. It melts at 843°C (1,549 °F).

Density8.6 g/cm³0.31 lb/in³
Melting Point (Solidus)843°C1,549 °F
Liquidus Temperature1,004°C1,839 °F

Mechanical13

C84200-M02 has a yield strength of 110 MPa (16 ksi) and a tensile strength of 255 MPa (37 ksi) — weaker than 82% of copper alloy grades. Elongation at break is 25% and the elastic modulus is 95 GPa (13.8 Msi).

Elastic (Young's) Modulus95 GPa13.8 Msi
Shear Modulus36 GPa5.2 Msi
Bulk Modulus100 GPa14.5 Msi
Poisson's Ratio0.34
Tensile Strength (Ultimate)255 MPa37 ksi
Yield Strength (0.2% offset)110 MPa16 ksi
Elongation at Break25%
Reduction in Area27%
Shear Strength170 MPa24.7 ksi
Fatigue Strength (Endurance Limit)83 MPa12 ksi
Charpy V-Notch Impact (RT)22 J16.2 ft·lbf
Hardness, Brinell58 HB
Hardness, Vickers61 HV

Thermal6

C84200-M02 is rated for continuous service to 200°C (392 °F). It conducts heat at 72 W/m·K (41.6 BTU/hr·ft·°F), worse than 52% of copper alloy grades. Thermal expansion is 18 µm/m·K (10 µin/in·°F).

Thermal Conductivity72 W/m·K41.6 BTU/hr·ft·°F
Specific Heat Capacity377 J/kg·K0.09 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)18 µm/m·K10 µin/in·°F
Latent Heat of Fusion170 J/g73.1 BTU/lb
Max Service Temperature (continuous)200°C392 °F
Min Service Temperature-196°C-321 °F

Electrical3

C84200-M02 conducts electricity at 16.4 % IACS, worse than 51% of copper alloy grades.

Electrical Conductivity16.4 % IACS
Electrical Resistivity1.05×10⁻⁷ Ω·m4.13 µΩ·in
Magnetic Responsenon-magnetic

Chemical & Environmental3

Corrosion resistance is good (63/100), better than 52% of copper alloy grades.

Galvanic Potential (seawater, vs SCE)-0.25 V
Corrosion ResistanceGood63/100
Chemical Resistance SummaryGood in fresh and potable water, atmosphere, non-oxidizing acids and neutral salts; attacked by ammonia/amines (SCC), oxidizing acids (nitric), sulfides and high-velocity or high-chloride seawater; unalloyed Zn content makes dezincification possible in soft or chlorinated water.

Sustainability4

Producing a kilogram of C84200-M02 takes about 55 MJ of energy and emits 3.6 kg of CO₂ — less than 72% of copper alloy grades. Typical recycled content is 85%.

Embodied Energy (primary production)55 MJ/kg23,646 BTU/lb
Embodied Carbon (primary production)3.6 kg CO₂/kg
Embodied Water260 L/kg31.2 gal/lb
Typical Recycled Content85%

Manufacturability8

C84200-M02's machinability is very good (80/100, better than 86% of copper alloy grades); weldability poor (20/100); formability poor (15/100).

MachinabilityVery good80/100
Machinability Rating (AISI 1212 = 100 %)80%
WeldabilityPoor20/100
Formability (cold)Poor15/100
CastabilityExcellent85/100
Brazeability / SolderabilityVery good80/100
PolishabilityGood65/100
Anodizing Responsen/a — copper alloy; use chemical/electroplated finishes (Ni, Cr, tin) or chromate/lacquer instead

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with C84200-M02

Is C84200 easy to machine?

Excellent free-machining behaviour (≈80 % of C36000); use sharp positive-rake carbide or HSS tooling, high speed, light feeds, and expect short chips from the lead phase.

Can C84200 be welded?

Fusion welding is not recommended — lead causes hot cracking and zinc fumes; join by soft soldering (excellent) or silver brazing with low-temperature filler and good ventilation.

Can C84200 be formed, bent or molded?

Foundry alloy only: good fluidity for thin plumbing sections, moderate shrinkage (~1.5 %), needs adequate risering and clean, degassed melt to avoid tin-oxide dross and micro-porosity.

What surface finishes work on C84200?

Takes electroplated nickel/chrome and tin plate readily, buffs to a bright brass finish (lead phase limits true mirror polish); lacquer or chromate to prevent tarnish — anodizing not applicable.

C84200 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
CuCu + named elements ≥ 99.3 %78 – 8280
Sn4 – 65
Pb2 – 32.5
Niincluding Co≤ 0.8—
Fe≤ 0.4—
Sb≤ 0.25—
S≤ 0.08—
P≤ 0.02—
Al≤ 0.01—
Si≤ 0.01—
Zn≥ 10 (balance)—

C84200-M02 — frequently asked

What is C84200-M02 used for?

C84200-M02 is typically used for valves, fittings and pump housings. In short: high-lead semi-red brass; good thin-section fluidity; not fusion weldable.

What is the yield strength of C84200-M02?

C84200-M02 has a typical yield strength of 110 MPa (16 ksi) and a tensile strength of 255 MPa (37 ksi) — weaker than 82% of copper alloy grades. Strength varies by condition: see the 5 listed tempers.

Is C84200-M02 easy to machine?

Yes — machinability is rated very good (80/100, better than 86% of copper alloy grades). Excellent free-machining behaviour (≈80 % of C36000); use sharp positive-rake carbide or HSS tooling, high speed, light feeds, and expect short chips from the lead phase.

Can C84200-M02 be welded?

Not readily — weldability is rated poor (20/100). Fusion welding is not recommended — lead causes hot cracking and zinc fumes; join by soft soldering (excellent) or silver brazing with low-temperature filler and good ventilation.

What surface finishes work on C84200-M02?

Takes electroplated nickel/chrome and tin plate readily, buffs to a bright brass finish (lead phase limits true mirror polish); lacquer or chromate to prevent tarnish — anodizing not applicable.

Can C84200-M02 be formed, bent or molded?

Foundry alloy only: good fluidity for thin plumbing sections, moderate shrinkage (~1.5 %), needs adequate risering and clean, degassed melt to avoid tin-oxide dross and micro-porosity.

What is the maximum service temperature of C84200-M02?

C84200-M02 is rated for continuous use to about 200°C (392 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between C84200-M01 and C84200-M07?

M01 is the default condition — standard as-cast sand casting condition for valve bodies, fittings and general plumbing hardware. M07: continuous-cast bar/tube stock — densest, most uniform structure and the best choice for machined-from-solid fittings. Yield strength is 103 MPa in M01 versus 124 MPa in M07.

Sources

  1. ASTM B584 — Standard Specification for Copper Alloy Sand Castings for General Applications — ASTM International (2022)
  2. ASTM B505/B505M — Copper Alloy Continuous Castings — ASTM International (2018)
  3. CDA Alloy Database — C84200 semi-red brass — Copper Development Association (2023)
  4. ASM Handbook Vol. 2 — Properties and Selection: Nonferrous Alloys — ASM International (1990)
  5. ASM Handbook Vol. 13B — Corrosion: Materials — ASM International (2005)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.