FabDigitFabDigit

Steel A182 F1 Q+T

Heat-treated state

ASTM A182 F1 · UNS K12822

Q+T = quenched and tempered

Used for heavy-section forgings where uniform properties and higher low-temperature toughness are required.

Standard cost $$

Values for the Q+T condition

Other A182 F1 tempers and conditions

A182 F1 is listed in 4 conditions; see the grade overview at A182 F1.

Compare all 4 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
Solution annealed
Choose when maximum softness, machinability and dimensional stability are wanted; lowest strength within the spec minimums.30050031148 HB8.4 % IACS
N+TDefault
Normalized and tempered
Standard supply condition for F1 flanges and fittings; best combination of strength, toughness and elevated-temperature stability.33053028160 HB—
prior to final heat treatment (semi-finished forgings only)
Intermediate condition supplied for further machining and mandatory heat treatment; not acceptable for A182 code certification as-is.34056024175 HB8.2 % IACS
Q+TThis page
Quenched and tempered
Used for heavy-section forgings where uniform properties and higher low-temperature toughness are required.38057026175 HB8 % IACS

What is A182 F1 Q+T?

A182 F1 Q+T is A182 F1 heat treated to Q+T — used for heavy-section forgings where uniform properties and higher low-temperature toughness are required. A182 F1 Q+T has a yield strength of 380 MPa (55.1 ksi) and a tensile strength of 570 MPa (82.7 ksi) — weaker than 68% of steel grades. Elongation at break is 26% and the elastic modulus is 205 GPa (29.7 Msi). A182 F1 Q+T has a density of 7.85 g/cm³ (0.284 lb/in³), heavier than 56% of steel grades. It melts at 1,460°C (2,660 °F). N+T is the default condition FabDigit quotes; Q+T is available on request or by drawing note.

Advantages

  • Tough — resists crack growth — 140 MPa·√m (127.4 ksi·√in), better than 94% of steel grades
  • High service temperature — 510°C (950 °F), better than 92% of steel grades
  • Ductile — tolerates forming and impact — 26%, better than 82% of steel grades

A182 F1 Q+T properties

Typical room-temperature values for A182 F1 Q+T; 22 are specific to this condition. Other listed values are A182 F1 reference data and may not represent this condition. Bars are the position among steel grades.

Physical3

A182 F1 Q+T has a density of 7.85 g/cm³ (0.284 lb/in³), heavier than 56% of steel grades. It melts at 1,460°C (2,660 °F).

Density7.85 g/cm³0.28 lb/in³
Melting Point (Solidus)1,460°C2,660 °F
Liquidus Temperature1,510°C2,750 °F

Mechanical16

A182 F1 Q+T has a yield strength of 380 MPa (55.1 ksi) and a tensile strength of 570 MPa (82.7 ksi) — weaker than 68% of steel grades. Elongation at break is 26% and the elastic modulus is 205 GPa (29.7 Msi).

Elastic (Young's) Modulus205 GPa29.7 Msi
Shear Modulus80 GPa11.6 Msi
Bulk Modulus160 GPa23.2 Msi
Poisson's Ratio0.29
Tensile Strength (Ultimate)570 MPa82.7 ksi
Yield Strength (0.2% offset)380 MPa55.1 ksi
Elongation at Break26%
Reduction in Area60%
Compressive Strength380 MPa55.1 ksi
Shear Strength370 MPa53.7 ksi
Fatigue Strength (Endurance Limit)265 MPa38.4 ksi
Fracture Toughness (K_IC)140 MPa·√m127 ksi·√in
Charpy V-Notch Impact (RT)90 J66.4 ft·lbf
Hardness, Brinell175 HB
Hardness, Rockwell B88 HRB
Hardness, Vickers184 HV

Thermal6

A182 F1 Q+T is rated for continuous service to 510°C (950 °F). It conducts heat at 42 W/m·K (24.3 BTU/hr·ft·°F), worse than 56% of steel grades. Thermal expansion is 12.3 µm/m·K (6.83 µin/in·°F).

Thermal Conductivity42 W/m·K24.3 BTU/hr·ft·°F
Specific Heat Capacity470 J/kg·K0.11 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)12.3 µm/m·K6.8 µin/in·°F
Latent Heat of Fusion250 J/g107 BTU/lb
Max Service Temperature (continuous)510°C950 °F
Min Service Temperature-29°C-20 °F

Electrical3

A182 F1 Q+T conducts electricity at 8 % IACS, better than 55% of steel grades.

Electrical Conductivity8 % IACS
Electrical Resistivity2.15×10⁻⁷ Ω·m8.46 µΩ·in
Magnetic Responseferromagnetic

Chemical & Environmental3

Corrosion resistance is not recommended (12/100), worse than 53% of steel grades.

Galvanic Potential (seawater, vs SCE)-0.62 V
Corrosion ResistanceNot recommended12/100
Chemical Resistance SummaryRusts freely in moist air and water; resists dry hydrocarbons, steam and neutral oils; attacked by acids, chlorides and wet H2S (HIC/SSC risk) — requires coating, inhibition or corrosion allowance.

Sustainability4

Producing a kilogram of A182 F1 Q+T takes about 30 MJ of energy and emits 2.2 kg of CO₂ — more than 56% of steel grades. Typical recycled content is 25%.

Embodied Energy (primary production)30 MJ/kg12,898 BTU/lb
Embodied Carbon (primary production)2.2 kg CO₂/kg
Embodied Water60 L/kg7.2 gal/lb
Typical Recycled Content25%

Manufacturability7

A182 F1 Q+T's machinability is fair (54/100, better than 54% of steel grades); weldability good (62/100); formability fair (48/100).

MachinabilityFair54/100
Machinability Rating (AISI 1212 = 100 %)55%
WeldabilityGood62/100
Formability (cold)Fair48/100
Brazeability / SolderabilityGood55/100
PolishabilityFair50/100
Anodizing Responsen/a — ferrous alloy; use painting, galvanizing, metallizing or electroless nickel instead

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with A182 F1 Q+T

Is A182 F1 easy to machine?

Machines like a medium-carbon steel at ~60% of 1212; use rigid setups, sharp carbide inserts and adequate coolant to avoid built-up edge on the softer annealed condition.

Can A182 F1 be welded?

Readily welded with matched E/ER 80S-D2 or E7018-A1 consumables; preheat 100–200 °C and PWHT at 620–700 °C are normally required for pressure service.

Can A182 F1 be formed, bent or molded?

Primarily hot-forged at 1100–1230 °C with finish above ~900 °C; cold forming is limited by moderate ductility and strain-aging sensitivity.

What surface finishes work on A182 F1?

No anodizing; protect with shop primer, epoxy paint, hot-dip galvanizing, metallizing or electroless nickel — plain surfaces rust rapidly.

A182 F1 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
C0.28 max≤ 0.280.22
Mn0.6 – 0.90.75
Si0.15 – 0.350.25
Mocarbon-molybdenum strengthening0.44 – 0.650.52
P0.045 max≤ 0.050.02
S0.045 max≤ 0.050.02
Febalance—

A182 F1 Q+T — frequently asked

What is A182 F1 Q+T used for?

A182 F1 Q+T is typically used for flanges, fittings, valve bodies and piping components for power plants. In short: entry-level C-Mo pressure forging; better creep than carbon steel; preheat and PWHT required.

What is the yield strength of A182 F1 Q+T?

A182 F1 Q+T has a typical yield strength of 380 MPa (55.1 ksi) and a tensile strength of 570 MPa (82.7 ksi) — weaker than 68% of steel grades. Strength varies by condition: see the 4 listed tempers.

Is A182 F1 Q+T easy to machine?

Reasonably — machinability is rated fair (54/100, better than 54% of steel grades). Machines like a medium-carbon steel at ~60% of 1212; use rigid setups, sharp carbide inserts and adequate coolant to avoid built-up edge on the softer annealed condition.

Can A182 F1 Q+T be welded?

Yes — weldability is rated good (62/100). Readily welded with matched E/ER 80S-D2 or E7018-A1 consumables; preheat 100–200 °C and PWHT at 620–700 °C are normally required for pressure service.

What surface finishes work on A182 F1 Q+T?

No anodizing; protect with shop primer, epoxy paint, hot-dip galvanizing, metallizing or electroless nickel — plain surfaces rust rapidly.

Can A182 F1 Q+T be formed, bent or molded?

Primarily hot-forged at 1100–1230 °C with finish above ~900 °C; cold forming is limited by moderate ductility and strain-aging sensitivity.

What is the maximum service temperature of A182 F1 Q+T?

A182 F1 Q+T is rated for continuous use to about 510°C (950 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between A182 F1 N+T and A182 F1-A?

N+T is the default condition — standard supply condition for F1 flanges and fittings; best combination of strength, toughness and elevated-temperature stability. A: choose when maximum softness, machinability and dimensional stability are wanted; lowest strength within the spec minimums. Yield strength is 330 MPa in N+T versus 300 MPa in A.

Sources

  1. ASTM A182/A182M — Forged or Rolled Alloy and Stainless Steel Pipe Flanges, Fittings, Valves and Parts for High-Temperature Service — ASTM International (2023)
  2. ASTM A335/A335M — Seamless Ferritic Alloy-Steel Pipe for High-Temperature Service (Grade P1) — ASTM International (2022)
  3. ASME BPVC Section II Part D — Properties (Metric) — ASME (2023)
  4. ASM Handbook Vol.1 — Properties and Selection: Irons, Steels, and High-Performance Alloys — ASM International (1990)
  5. API RP 941 — Steels for Hydrogen Service / graphitization guidance — API (2016)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.