FabDigitFabDigit

Steel P500QL2 QT-50-100

Heat-treated state

EN 1.8865, 10028-6

QT-50-100 = q+T

Heavy plate condition; slightly lower guaranteed yield due to reduced quench severity through thickness.

Budget cost $

Values for the QT-50-100 condition

Other P500QL2 tempers and conditions

P500QL2 is listed in 4 conditions; see the grade overview at P500QL2.

Compare all 4 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
Q+T
Maximum thickness range offered; use when wall thickness governs and the reduced yield is acceptable.4806102013 HRC7.2 % IACS
QT-50-100This page
Q+T
Heavy plate condition; slightly lower guaranteed yield due to reduced quench severity through thickness.5206402116 HRC7.2 % IACS
Q+T + stress relieved / simulated PWHT
Order this when the fabricated vessel will see PWHT — properties are certified after a simulated post-weld heat treatment cycle below the tempering temperature.5206302215 HRC7.2 % IACS
QTDefault
Quenched and tempered
Standard delivery condition for plate up to 50 mm — full 500 MPa minimum yield with −60 °C toughness.5456602119 HRC7.2 % IACS

What is P500QL2 QT-50-100?

P500QL2 QT-50-100 is P500QL2 heat treated to QT-50-100 — heavy plate condition; slightly lower guaranteed yield due to reduced quench severity through thickness. P500QL2 QT-50-100 has a yield strength of 520 MPa (75.4 ksi) and a tensile strength of 640 MPa (92.8 ksi) — stronger than 67% of steel grades. Elongation at break is 21% and the elastic modulus is 210 GPa (30.5 Msi). P500QL2 QT-50-100 has a density of 7.85 g/cm³ (0.284 lb/in³), heavier than 56% of steel grades. It melts at 1,420°C (2,588 °F). QT is the default condition FabDigit quotes; QT-50-100 is available on request or by drawing note.

Advantages

  • Tough — resists crack growth — 125 MPa·√m (113.8 ksi·√in), better than 85% of steel grades

P500QL2 QT-50-100 properties

Typical room-temperature values for P500QL2 QT-50-100; 24 are specific to this condition. Other listed values are P500QL2 reference data and may not represent this condition. Bars are the position among steel grades.

Physical3

P500QL2 QT-50-100 has a density of 7.85 g/cm³ (0.284 lb/in³), heavier than 56% of steel grades. It melts at 1,420°C (2,588 °F).

Density7.85 g/cm³0.28 lb/in³
Melting Point (Solidus)1,420°C2,588 °F
Liquidus Temperature1,500°C2,732 °F

Mechanical17

P500QL2 QT-50-100 has a yield strength of 520 MPa (75.4 ksi) and a tensile strength of 640 MPa (92.8 ksi) — stronger than 67% of steel grades. Elongation at break is 21% and the elastic modulus is 210 GPa (30.5 Msi).

Elastic (Young's) Modulus210 GPa30.5 Msi
Shear Modulus81 GPa11.7 Msi
Bulk Modulus160 GPa23.2 Msi
Poisson's Ratio0.29
Tensile Strength (Ultimate)640 MPa92.8 ksi
Yield Strength (0.2% offset)520 MPa75.4 ksi
Elongation at Break21%
Reduction in Area58%
Compressive Strength520 MPa75.4 ksi
Shear Strength385 MPa55.8 ksi
Fatigue Strength (Endurance Limit)290 MPa42.1 ksi
Fracture Toughness (K_IC)125 MPa·√m114 ksi·√in
Charpy V-Notch Impact (RT)120 J88.5 ft·lbf
Hardness, Brinell205 HB
Hardness, Rockwell B93 HRB
Hardness, Rockwell C16 HRC
Hardness, Vickers215 HV

Thermal6

P500QL2 QT-50-100 is rated for continuous service to 400°C (752 °F). It conducts heat at 38 W/m·K (22 BTU/hr·ft·°F), worse than 69% of steel grades. Thermal expansion is 12 µm/m·K (6.67 µin/in·°F).

Thermal Conductivity38 W/m·K22 BTU/hr·ft·°F
Specific Heat Capacity460 J/kg·K0.11 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)12 µm/m·K6.7 µin/in·°F
Latent Heat of Fusion270 J/g116 BTU/lb
Max Service Temperature (continuous)400°C752 °F
Min Service Temperature-60°C-76 °F

Electrical3

P500QL2 QT-50-100 conducts electricity at 7.2 % IACS, worse than 71% of steel grades.

Electrical Conductivity7.2 % IACS
Electrical Resistivity2.4×10⁻⁷ Ω·m9.45 µΩ·in
Magnetic Responseferromagnetic

Chemical & Environmental3

Corrosion resistance is poor (15/100), better than 75% of steel grades.

Galvanic Potential (seawater, vs SCE)-0.62 V
Corrosion ResistancePoor15/100
Chemical Resistance SummaryNot corrosion resistant: rusts in humid air and water; requires paint, metallizing or cladding. Susceptible to hydrogen-induced and sulphide stress cracking in wet H2S service unless hardness is controlled below 248 HV per NACE MR0175.

Sustainability4

Producing a kilogram of P500QL2 QT-50-100 takes about 30 MJ of energy and emits 2.3 kg of CO₂ — more than 56% of steel grades. Typical recycled content is 20%.

Embodied Energy (primary production)30 MJ/kg12,898 BTU/lb
Embodied Carbon (primary production)2.3 kg CO₂/kg
Embodied Water60 L/kg7.2 gal/lb
Typical Recycled Content20%

Manufacturability7

P500QL2 QT-50-100's machinability is fair (47/100, worse than 58% of steel grades); weldability good (58/100); formability fair (38/100).

MachinabilityFair47/100
Machinability Rating (AISI 1212 = 100 %)57%
WeldabilityGood58/100
Formability (cold)Fair38/100
Brazeability / SolderabilityFair40/100
PolishabilityGood55/100
Anodizing Responsen/a — ferrous alloy; use painting, zinc/metallizing or phosphating instead

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with P500QL2 QT-50-100

Is P500QL2 easy to machine?

Machines like a 215 HB Q&T alloy steel — use rigid setups, coated carbide, moderate speeds; avoid heavy grinding that could re-temper or crack the surface.

Can P500QL2 be welded?

Weldable by SAW/FCAW/SMAW with low-hydrogen consumables; preheat 100–150 °C (higher for t>50 mm), control interpass ≤250 °C and heat input to protect the −60 °C HAZ toughness, and keep PWHT below the tempering temperature.

Can P500QL2 be formed, bent or molded?

Cold form with bend radii ≥3t across the rolling direction; hot forming above ~580 °C destroys the Q&T condition and requires full re-quench and temper.

What surface finishes work on P500QL2?

No inherent corrosion resistance — blast to Sa 2½ and apply epoxy/zinc-rich paint or metallizing; keep surface hardness ≤248 HV for wet H2S service.

P500QL2 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
Cladle analysis≤ 0.180.15
Si≤ 0.60.3
Mn0.8 – 1.71.3
PQL2 grade, low P for toughness≤ 0.020.01
SQL2 grade, calcium-treated≤ 0.010
N≤ 0.020.01
Altotal Al, grain refinement≥ 0.020.04
Cr≤ 1.50.5
Cu≤ 0.50.15
Mo≤ 0.70.45
Nimain contributor to low-temperature toughness≤ 2.51.2
Nb≤ 0.060.03
Ti≤ 0.050.02
V≤ 0.120.05
Zr≤ 0.05—
Bhardenability booster≤ 0.010
Febalance—

P500QL2 QT-50-100 — frequently asked

What is P500QL2 QT-50-100 used for?

P500QL2 QT-50-100 is typically used for high-pressure cryogenic vessels, LNG tanks and chemical reactors. In short: 500 MPa Q&T vessel plate; L2 toughness at high strength; step above P460QL2.

What is the yield strength of P500QL2 QT-50-100?

P500QL2 QT-50-100 has a typical yield strength of 520 MPa (75.4 ksi) and a tensile strength of 640 MPa (92.8 ksi) — stronger than 67% of steel grades. Strength varies by condition: see the 4 listed tempers.

Is P500QL2 QT-50-100 easy to machine?

Reasonably — machinability is rated fair (47/100, worse than 58% of steel grades). Machines like a 215 HB Q&T alloy steel — use rigid setups, coated carbide, moderate speeds; avoid heavy grinding that could re-temper or crack the surface.

Can P500QL2 QT-50-100 be welded?

Yes — weldability is rated good (58/100). Weldable by SAW/FCAW/SMAW with low-hydrogen consumables; preheat 100–150 °C (higher for t>50 mm), control interpass ≤250 °C and heat input to protect the −60 °C HAZ toughness, and keep PWHT below the tempering temperature.

What surface finishes work on P500QL2 QT-50-100?

No inherent corrosion resistance — blast to Sa 2½ and apply epoxy/zinc-rich paint or metallizing; keep surface hardness ≤248 HV for wet H2S service.

Can P500QL2 QT-50-100 be formed, bent or molded?

Cold form with bend radii ≥3t across the rolling direction; hot forming above ~580 °C destroys the Q&T condition and requires full re-quench and temper.

What is the maximum service temperature of P500QL2 QT-50-100?

P500QL2 QT-50-100 is rated for continuous use to about 400°C (752 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

Sources

  1. EN 10028-6 — Flat products made of steels for pressure purposes, Part 6: Weldable fine grain steels, quenched and tempered — CEN (2020)
  2. EN 10025-6 / EN 10029 (tolerances, related Q&T plate practice) — CEN (2019)
  3. ASM Handbook Vol. 1 — Properties and Selection: Irons, Steels and High-Performance Alloys — ASM International (1990)
  4. Quenched and tempered pressure vessel plate datasheets (Dillinger, SSAB, thyssenkrupp) — various producers (2023)
  5. NACE MR0175 / ISO 15156-2 hardness limits for wet H2S service — ISO/NACE (2020)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.