FabDigitFabDigit

Steel A182 FR N+T

Heat-treated state · default condition

ASTM A182 FR · UNS K22035

N+T = normalized and tempered

Standard mill-supplied condition for A182 FR flanges and fittings; best balance of strength and −46 °C notch toughness.

Standard cost $$

Values for the N+T condition

Other A182 FR tempers and conditions

A182 FR is listed in 3 conditions; see the grade overview at A182 FR.

Compare all 3 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
Normalized
Normalized-only forgings for thin sections where tempering is not required and moderate strength suffices.33050527150 HB7.5 % IACS
N+TDefaultThis page
Normalized and tempered
Standard mill-supplied condition for A182 FR flanges and fittings; best balance of strength and −46 °C notch toughness.35552026160 HB—
Quenched and tempered
Choose for heavy-section forgings or when the highest low-temperature impact energy and through-thickness properties are needed.45058523185 HB—

What is A182 FR N+T?

A182 FR N+T is A182 FR heat treated to N+T — standard mill-supplied condition for A182 FR flanges and fittings; best balance of strength and −46 °C notch toughness. A182 FR N+T has a yield strength of 355 MPa (51.5 ksi) and a tensile strength of 520 MPa (75.4 ksi) — weaker than 73% of steel grades. Elongation at break is 26% and the elastic modulus is 205 GPa (29.7 Msi). A182 FR N+T has a density of 7.85 g/cm³ (0.284 lb/in³), heavier than 56% of steel grades. It melts at 1,450°C (2,642 °F).

Advantages

  • Good corrosion resistance — 22/100, better than 90% of steel grades
  • Ductile — tolerates forming and impact — 26%, better than 82% of steel grades
  • Tough — resists crack growth — 120 MPa·√m (109.2 ksi·√in), better than 81% of steel grades

A182 FR N+T properties

Typical room-temperature values for A182 FR N+T; 13 are specific to this condition. Other listed values are A182 FR reference data and may not represent this condition. Bars are the position among steel grades.

Physical3

A182 FR N+T has a density of 7.85 g/cm³ (0.284 lb/in³), heavier than 56% of steel grades. It melts at 1,450°C (2,642 °F).

Density7.85 g/cm³0.28 lb/in³
Melting Point (Solidus)1,450°C2,642 °F
Liquidus Temperature1,505°C2,741 °F

Mechanical15

A182 FR N+T has a yield strength of 355 MPa (51.5 ksi) and a tensile strength of 520 MPa (75.4 ksi) — weaker than 73% of steel grades. Elongation at break is 26% and the elastic modulus is 205 GPa (29.7 Msi).

Elastic (Young's) Modulus205 GPa29.7 Msi
Shear Modulus80 GPa11.6 Msi
Bulk Modulus160 GPa23.2 Msi
Poisson's Ratio0.29
Tensile Strength (Ultimate)520 MPa75.4 ksi
Yield Strength (0.2% offset)355 MPa51.5 ksi
Elongation at Break26%
Reduction in Area58%
Compressive Strength355 MPa51.5 ksi
Shear Strength330 MPa47.9 ksi
Fatigue Strength (Endurance Limit)250 MPa36.3 ksi
Fracture Toughness (K_IC)120 MPa·√m109 ksi·√in
Charpy V-Notch Impact (RT)150 J111 ft·lbf
Hardness, Brinell160 HB
Hardness, Rockwell B84 HRB

Thermal6

A182 FR N+T is rated for continuous service to 400°C (752 °F). It conducts heat at 40 W/m·K (23.1 BTU/hr·ft·°F), worse than 64% of steel grades. Thermal expansion is 11.7 µm/m·K (6.5 µin/in·°F).

Thermal Conductivity40 W/m·K23.1 BTU/hr·ft·°F
Specific Heat Capacity470 J/kg·K0.11 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)11.7 µm/m·K6.5 µin/in·°F
Latent Heat of Fusion250 J/g107 BTU/lb
Max Service Temperature (continuous)400°C752 °F
Min Service Temperature-46°C-51 °F

Electrical3

A182 FR N+T conducts electricity at 7.5 % IACS, worse than 67% of steel grades.

Electrical Conductivity7.5 % IACS
Electrical Resistivity2.3×10⁻⁷ Ω·m9.06 µΩ·in
Magnetic Responseferromagnetic

Chemical & Environmental3

Corrosion resistance is poor (22/100), better than 90% of steel grades.

Galvanic Potential (seawater, vs SCE)-0.62 V
Corrosion ResistancePoor22/100
Chemical Resistance SummaryRusts freely in wet or chloride service; the Cu-Cr-Ni addition forms a protective patina in ordinary atmospheric exposure. Not resistant to acids; requires coating, painting or corrosion allowance for sour/aqueous duty.

Sustainability4

Producing a kilogram of A182 FR N+T takes about 26 MJ of energy and emits 2.1 kg of CO₂ — less than 64% of steel grades. Typical recycled content is 30%.

Embodied Energy (primary production)26 MJ/kg11,178 BTU/lb
Embodied Carbon (primary production)2.1 kg CO₂/kg
Embodied Water40 L/kg4.8 gal/lb
Typical Recycled Content30%

Manufacturability7

A182 FR N+T's machinability is good (58/100, better than 75% of steel grades); weldability good (65/100); formability fair (45/100).

MachinabilityGood58/100
Machinability Rating (AISI 1212 = 100 %)60%
WeldabilityGood65/100
Formability (cold)Fair45/100
Brazeability / SolderabilityFair50/100
PolishabilityFair50/100
Anodizing Responsen/a — ferrous alloy; use paint, zinc/epoxy coating or electroless nickel instead

Common Calculations5

Specific Strength (UTS / density)calculated66 kN·m/kg
Specific Stiffness (E / density)calculated26.1 MN·m/kg
Modulus of Resiliencecalculated307 kJ/m³
Thermal Diffusivitycalculated10.8 mm²/s
Thermal Shock Resistance Indexcalculated9

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with A182 FR N+T

Is A182 FR easy to machine?

Machines like normalized 4130/A350-class steel at ~60 % of AISI 1212; use rigid setups, carbide inserts and moderate speeds — copper content can cause slight gumminess in soft condition.

Can A182 FR be welded?

Weldable with low-hydrogen SMAW/GTAW/SAW using matching or 1–2 %Ni filler; preheat 100–150 °C, control interpass, and PWHT/temper at ~595–650 °C to restore −46 °C notch toughness.

Can A182 FR be formed, bent or molded?

Hot forge at 1050–1200 °C with finishing above 900 °C, then normalize (or quench) and temper; cold forming is limited and should be followed by stress relief.

What surface finishes work on A182 FR?

Not anodizable — protect with shop primer, epoxy/zinc-rich paint, hot-dip galvanizing or electroless nickel; bare surfaces will form a weathering patina outdoors.

A182 FR chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
Cmax per ASTM A182 Grade FR≤ 0.20.15
Mn0.4 – 1.060.8
Si0.15 – 0.30.22
Pimpurity limit≤ 0.050.02
Simpurity limit≤ 0.050.01
Niprovides low-temperature toughness1.6 – 2.241.9
Cr0.7 – 1.10.9
Cuatmospheric corrosion resistance0.75 – 1.251
Febalance—

A182 FR N+T — frequently asked

What is A182 FR N+T used for?

A182 FR N+T is typically used for LNG piping flanges, low-temperature valve bodies and cold-service fittings. In short: cryogenic-toughness nickel forging; best weldability in family; qualified at −46 °C.

What is the yield strength of A182 FR N+T?

A182 FR N+T has a typical yield strength of 355 MPa (51.5 ksi) and a tensile strength of 520 MPa (75.4 ksi) — weaker than 73% of steel grades. Strength varies by condition: see the 3 listed tempers.

Is A182 FR N+T easy to machine?

Reasonably — machinability is rated good (58/100, better than 75% of steel grades). Machines like normalized 4130/A350-class steel at ~60 % of AISI 1212; use rigid setups, carbide inserts and moderate speeds — copper content can cause slight gumminess in soft condition.

Can A182 FR N+T be welded?

Yes — weldability is rated good (65/100). Weldable with low-hydrogen SMAW/GTAW/SAW using matching or 1–2 %Ni filler; preheat 100–150 °C, control interpass, and PWHT/temper at ~595–650 °C to restore −46 °C notch toughness.

What surface finishes work on A182 FR N+T?

Not anodizable — protect with shop primer, epoxy/zinc-rich paint, hot-dip galvanizing or electroless nickel; bare surfaces will form a weathering patina outdoors.

Can A182 FR N+T be formed, bent or molded?

Hot forge at 1050–1200 °C with finishing above 900 °C, then normalize (or quench) and temper; cold forming is limited and should be followed by stress relief.

What is the maximum service temperature of A182 FR N+T?

A182 FR N+T is rated for continuous use to about 400°C (752 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between A182 FR N+T and A182 FR-N?

N+T is the default condition — standard mill-supplied condition for A182 FR flanges and fittings; best balance of strength and −46 °C notch toughness. N: normalized-only forgings for thin sections where tempering is not required and moderate strength suffices. Yield strength is 355 MPa in N+T versus 330 MPa in N.

Sources

  1. ASTM A182/A182M — Forged or Rolled Alloy and Stainless Steel Pipe Flanges, Forged Fittings, and Valves and Parts — ASTM International (2023)
  2. ASTM A350/A350M — Carbon and Low-Alloy Steel Forgings Requiring Notch Toughness Testing (Grade LF9 comparison) — ASTM International (2022)
  3. ASME BPVC Section II Part D — Physical and allowable stress data for low-alloy steels — ASME (2023)
  4. ASME B16.5 / B16.34 — Pipe Flanges and Valve Material Groups — ASME (2020)
  5. ASM Handbook Vol.1 — Properties and Selection: Irons, Steels, and High-Performance Alloys — ASM International (1990)
  6. ASM Handbook Vol.13A — Corrosion: Fundamentals, Testing, and Protection (weathering steels) — ASM International (2003)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.