FabDigitFabDigit

Steel G17CrMo5-5-F (As fabricated)

Temper

ASTM A217 Gr. WC6 · EN 1.7357

Foundry intermediate state only — not permitted for pressure service; hard, brittle bainitic/martensitic areas and high residual stress.

Standard cost $$

Values for the F condition

Other G17CrMo5-5 tempers and conditions

G17CrMo5-5 is listed in 5 conditions; see the grade overview at G17CrMo5-5.

Compare all 5 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
Annealed
Choose for maximum machinability and lowest hardness before final quench-and-temper or for low-stress non-pressure parts.29050026145 HB—
Normalized (~ 920–960 °C, air cool) and tempered 680–730 °C
Standard route for thick-walled or complex castings where quenching risks cracking; slightly lower yield than +QT but very stable at temperature.35054523165 HB7.8 % IACS
Quenched and tempered, then post-weld/stress-relieved 620–680 °C
For castings that have been weld-repaired or welded into assemblies; PWHT below the tempering temperature restores toughness with a small drop in strength.36055523168 HB7.8 % IACS
+QTDefault
Quenched and tempered
Default delivery condition per EN 10213 for pressure castings: best combination of 315 MPa min yield, 20 % elongation and 40 J CVN.38057022175 HB—
FThis page
As fabricated
Foundry intermediate state only — not permitted for pressure service; hard, brittle bainitic/martensitic areas and high residual stress.4006501218 HRC7.6 % IACS

What is G17CrMo5-5-F?

G17CrMo5-5-F is G17CrMo5-5 in the F temper — foundry intermediate state only — not permitted for pressure service; hard, brittle bainitic/martensitic areas and high residual stress. G17CrMo5-5-F has a yield strength of 400 MPa (58 ksi) and a tensile strength of 650 MPa (94.3 ksi) — weaker than 60% of steel grades. Elongation at break is 12% and the elastic modulus is 210 GPa (30.5 Msi). G17CrMo5-5-F has a density of 7.85 g/cm³ (0.284 lb/in³), heavier than 56% of steel grades. It melts at 1,450°C (2,642 °F). +QT is the default condition FabDigit quotes; F is available on request or by drawing note.

Limitations

  • Limited formability — 10/100, worse than 95% of steel grades
  • Limited service temperature — 200°C (392 °F), worse than 93% of steel grades
  • Limited ductility — 12%, worse than 84% of steel grades
  • Low fracture toughness — 55 MPa·√m (50.1 ksi·√in), worse than 82% of steel grades

G17CrMo5-5-F properties

Typical room-temperature values for G17CrMo5-5-F; 23 are specific to this condition. Other listed values are G17CrMo5-5 reference data and may not represent this condition. Bars are the position among steel grades.

Physical3

G17CrMo5-5-F has a density of 7.85 g/cm³ (0.284 lb/in³), heavier than 56% of steel grades. It melts at 1,450°C (2,642 °F).

Density7.85 g/cm³0.28 lb/in³
Melting Point (Solidus)1,450°C2,642 °F
Liquidus Temperature1,510°C2,750 °F

Mechanical16

G17CrMo5-5-F has a yield strength of 400 MPa (58 ksi) and a tensile strength of 650 MPa (94.3 ksi) — weaker than 60% of steel grades. Elongation at break is 12% and the elastic modulus is 210 GPa (30.5 Msi).

Elastic (Young's) Modulus210 GPa30.5 Msi
Shear Modulus81 GPa11.7 Msi
Bulk Modulus160 GPa23.2 Msi
Poisson's Ratio0.29
Tensile Strength (Ultimate)650 MPa94.3 ksi
Yield Strength (0.2% offset)400 MPa58 ksi
Elongation at Break12%
Reduction in Area25%
Compressive Strength410 MPa59.5 ksi
Shear Strength400 MPa58 ksi
Fatigue Strength (Endurance Limit)250 MPa36.3 ksi
Fracture Toughness (K_IC)55 MPa·√m50.1 ksi·√in
Charpy V-Notch Impact (RT)18 J13.3 ft·lbf
Hardness, Brinell220 HB
Hardness, Rockwell B97 HRB
Hardness, Vickers231 HV

Thermal6

G17CrMo5-5-F is rated for continuous service to 200°C (392 °F). It conducts heat at 41 W/m·K (23.7 BTU/hr·ft·°F), worse than 62% of steel grades. Thermal expansion is 12.3 µm/m·K (6.83 µin/in·°F).

Thermal Conductivity41 W/m·K23.7 BTU/hr·ft·°F
Specific Heat Capacity465 J/kg·K0.11 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)12.3 µm/m·K6.8 µin/in·°F
Latent Heat of Fusion270 J/g116 BTU/lb
Max Service Temperature (continuous)200°C392 °F
Min Service Temperature-29°C-20 °F

Electrical3

G17CrMo5-5-F conducts electricity at 7.6 % IACS, worse than 65% of steel grades.

Electrical Conductivity7.6 % IACS
Electrical Resistivity2.27×10⁻⁷ Ω·m8.94 µΩ·in
Magnetic Responseferromagnetic

Chemical & Environmental3

Corrosion resistance is not recommended (14/100), better than 70% of steel grades.

Galvanic Potential (seawater, vs SCE)-0.62 V
Corrosion ResistanceNot recommended14/100
Chemical Resistance SummaryRusts freely in moist air and water; suitable for dry steam, oil and non-corrosive process fluids. Moderate resistance to high-temperature oxidation to ~550 °C and better than carbon steel against hydrogen attack (Nelson-curve service), but no resistance to acids, chlorides or wet H2S without cladding/coating.

Sustainability4

Producing a kilogram of G17CrMo5-5-F takes about 27 MJ of energy and emits 2.2 kg of CO₂ — less than 59% of steel grades. Typical recycled content is 80%.

Embodied Energy (primary production)27 MJ/kg11,608 BTU/lb
Embodied Carbon (primary production)2.2 kg CO₂/kg
Embodied Water55 L/kg6.6 gal/lb
Typical Recycled Content80%

Manufacturability8

G17CrMo5-5-F's machinability is fair (42/100, worse than 73% of steel grades); weldability fair (45/100); formability not recommended (10/100).

MachinabilityFair42/100
Machinability Rating (AISI 1212 = 100 %)45%
WeldabilityFair45/100
Formability (cold)Not recommended10/100
CastabilityGood65/100
Brazeability / SolderabilityGood55/100
PolishabilityGood55/100
Anodizing Responsen/a — ferrous alloy; use paint, zinc/Al metallizing or Ni plating instead

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with G17CrMo5-5-F

Is G17CrMo5-5 easy to machine?

Machines like annealed 4130/4140 at ~60 % of AISI 1212 — use rigid setups, coated carbide, moderate speed and generous coolant; expect hard spots at chills and in un-tempered as-cast areas.

Can G17CrMo5-5 be welded?

Weldable with matched E/ER 80S-B2 or E8018-B2 filler; preheat 200–250 °C, interpass ≤ 350 °C, low-hydrogen practice, and mandatory PWHT at 680–730 °C to avoid hydrogen and reheat cracking.

Can G17CrMo5-5 be formed, bent or molded?

Sand or investment cast with generous risering (solidification range is wide); design 3–5 % shrink allowance, avoid abrupt section changes, and always heat treat (+N+T or +QT) before proof testing.

What surface finishes work on G17CrMo5-5?

Not corrosion resistant — shot blast then apply high-temperature aluminium/silicone paint, Al metallizing or Ni/Cr plating; machined sealing faces are often hardfaced with Stellite in valve service.

G17CrMo5-5 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
CEN 10213; A217 WC6 allows 0.05–0.200.15 – 0.20.17
Si≤ 0.60.4
Mn0.5 – 10.75
P≤ 0.020.01
S≤ 0.020.01
Cr1 – 1.51.25
Mo0.45 – 0.650.55
Niresidual≤ 0.40.15
Curesidual≤ 0.30.15
Vresidual≤ 0.050.02
Febalance—

G17CrMo5-5-F — frequently asked

What is G17CrMo5-5-F used for?

G17CrMo5-5-F is typically used for steam valve bodies, power plant pressure castings and high-temperature piping fittings. In short: A217 WC6 pressure casting; creep service to 550 °C; standard steam valve grade.

What is the yield strength of G17CrMo5-5-F?

G17CrMo5-5-F has a typical yield strength of 400 MPa (58 ksi) and a tensile strength of 650 MPa (94.3 ksi) — weaker than 60% of steel grades. Strength varies by condition: see the 5 listed tempers.

Is G17CrMo5-5-F easy to machine?

Not especially — machinability is rated fair (42/100, worse than 73% of steel grades). Machines like annealed 4130/4140 at ~60 % of AISI 1212 — use rigid setups, coated carbide, moderate speed and generous coolant; expect hard spots at chills and in un-tempered as-cast areas.

Can G17CrMo5-5-F be welded?

With care — weldability is rated fair (45/100). Weldable with matched E/ER 80S-B2 or E8018-B2 filler; preheat 200–250 °C, interpass ≤ 350 °C, low-hydrogen practice, and mandatory PWHT at 680–730 °C to avoid hydrogen and reheat cracking.

What surface finishes work on G17CrMo5-5-F?

Not corrosion resistant — shot blast then apply high-temperature aluminium/silicone paint, Al metallizing or Ni/Cr plating; machined sealing faces are often hardfaced with Stellite in valve service.

Can G17CrMo5-5-F be formed, bent or molded?

Sand or investment cast with generous risering (solidification range is wide); design 3–5 % shrink allowance, avoid abrupt section changes, and always heat treat (+N+T or +QT) before proof testing.

What is the maximum service temperature of G17CrMo5-5-F?

G17CrMo5-5-F is rated for continuous use to about 200°C (392 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between G17CrMo5-5 +QT and G17CrMo5-5-F?

+QT is the default condition — default delivery condition per EN 10213 for pressure castings: best combination of 315 MPa min yield, 20 % elongation and 40 J CVN. F: foundry intermediate state only — not permitted for pressure service; hard, brittle bainitic/martensitic areas and high residual stress. Yield strength is 380 MPa in +QT versus 400 MPa in F.

Sources

  1. EN 10213 — Steel castings for pressure purposes — CEN (2016)
  2. ASTM A217/A217M — Martensitic stainless and alloy steel castings for pressure-containing parts (Gr. WC6) — ASTM International (2021)
  3. ASME BPVC Section II Part D — Material properties (1.25Cr-0.5Mo) — ASME (2023)
  4. Steel Castings Handbook, 6th ed. — Steel Founders' Society of America / ASM (1995)
  5. ASM Handbook Vol. 1 — Properties and Selection: Irons, Steels and High-Performance Alloys — ASM International (1990)
  6. GB/T 16253 — (ZG20CrMo class) — SAC (2019)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.