FabDigitFabDigit

Titanium B817 Type I GR2-CLB

Grade

ASTM B817 Type I

GR2-CLB = type I Grade 2, Class B

Lower-cost sintered condition for static, corrosion-driven applications where fatigue and toughness are not critical.

High cost $$$$

Values for the GR2-CLB condition

Other B817 Type I tempers and conditions

B817 Type I is listed in 5 conditions; see the grade overview at B817 Type I.

Compare all 5 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
Type I Grade 1, Class B
Economy press-and-sinter condition for lightly loaded corrosion-resistant parts where residual porosity is acceptable.20027012120 HB2.7 % IACS
Type I Grade 1, Class A
Pick when maximum ductility, formability and corrosion resistance are wanted in a fully densified P/M part.24033022130 HB3.3 % IACS
GR2-CLBThis page
Type I Grade 2, Class B
Lower-cost sintered condition for static, corrosion-driven applications where fatigue and toughness are not critical.3003809145 HB2.6 % IACS
GR2-CLADefault
Type I Grade 2, Class A
The workhorse condition: best balance of strength, ductility and corrosion resistance for MIM/HIP CP-Ti parts.35045018160 HB3.1 % IACS
Hot isostatic pressed
Specify when fatigue-critical or medical parts need near-full density and closed internal porosity.38048024165 HB17 W/m·K

What is B817 Type I GR2-CLB?

B817 Type I GR2-CLB is B817 Type I in the GR2-CLB grade — lower-cost sintered condition for static, corrosion-driven applications where fatigue and toughness are not critical. B817 Type I GR2-CLB has a yield strength of 300 MPa (43.5 ksi) and a tensile strength of 380 MPa (55.1 ksi) — weaker than 88% of titanium grades. Elongation at break is 9% and the elastic modulus is 88 GPa (12.8 Msi). B817 Type I GR2-CLB has a density of 4.28 g/cm³ (0.155 lb/in³), lighter than 100% of titanium grades. It melts at 1,660°C (3,020 °F). GR2-CLA is the default condition FabDigit quotes; GR2-CLB is available on request or by drawing note.

Advantages

  • Easy to machine — 40/100, better than 93% of titanium grades

Limitations

  • Needs corrosion protection — 76/100, worse than 100% of titanium grades
  • Low fracture toughness — 40 MPa·√m (36.4 ksi·√in), worse than 99% of titanium grades
  • Limited ductility — 9%, worse than 97% of titanium grades
  • Low stiffness — 88 GPa (12.8 Msi), worse than 95% of titanium grades
  • High embodied carbon — 48 kg CO₂/kg, worse than 95% of titanium grades

B817 Type I GR2-CLB properties

Typical room-temperature values for B817 Type I GR2-CLB; 22 are specific to this condition. Other listed values are B817 Type I reference data and may not represent this condition. Bars are the position among titanium grades.

Physical3

B817 Type I GR2-CLB has a density of 4.28 g/cm³ (0.155 lb/in³), lighter than 100% of titanium grades. It melts at 1,660°C (3,020 °F).

Density4.28 g/cm³0.15 lb/in³
Melting Point (Solidus)1,660°C3,020 °F
Liquidus Temperature1,670°C3,038 °F

Mechanical16

B817 Type I GR2-CLB has a yield strength of 300 MPa (43.5 ksi) and a tensile strength of 380 MPa (55.1 ksi) — weaker than 88% of titanium grades. Elongation at break is 9% and the elastic modulus is 88 GPa (12.8 Msi).

Elastic (Young's) Modulus88 GPa12.8 Msi
Shear Modulus38 GPa5.5 Msi
Bulk Modulus110 GPa16 Msi
Poisson's Ratio0.34
Tensile Strength (Ultimate)380 MPa55.1 ksi
Yield Strength (0.2% offset)300 MPa43.5 ksi
Elongation at Break9%
Reduction in Area14%
Compressive Strength450 MPa65.3 ksi
Shear Strength250 MPa36.3 ksi
Fatigue Strength (Endurance Limit)130 MPa18.9 ksi
Fracture Toughness (K_IC)40 MPa·√m36.4 ksi·√in
Charpy V-Notch Impact (RT)9 J6.6 ft·lbf
Hardness, Brinell145 HB
Hardness, Rockwell B77 HRB
Hardness, Vickers155 HV

Thermal6

B817 Type I GR2-CLB is rated for continuous service to 280°C (536 °F). It conducts heat at 13 W/m·K (7.51 BTU/hr·ft·°F), better than 58% of titanium grades. Thermal expansion is 8.6 µm/m·K (4.78 µin/in·°F).

Thermal Conductivity13 W/m·K7.5 BTU/hr·ft·°F
Specific Heat Capacity523 J/kg·K0.12 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)8.6 µm/m·K4.8 µin/in·°F
Latent Heat of Fusion295 J/g127 BTU/lb
Max Service Temperature (continuous)280°C536 °F
Min Service Temperature-250°C-418 °F

Electrical3

B817 Type I GR2-CLB conducts electricity at 2.6 % IACS, better than 56% of titanium grades.

Electrical Conductivity2.6 % IACS
Electrical Resistivity5.6×10⁻⁷ Ω·m22 µΩ·in
Magnetic Responsenon-magnetic

Chemical & Environmental3

Corrosion resistance is very good (76/100), worse than 100% of titanium grades.

Galvanic Potential (seawater, vs SCE)-0.1 V
Corrosion ResistanceVery good76/100
Chemical Resistance SummaryExcellent in seawater, chlorides, oxidizing acids (HNO₃), wet chlorine and most body fluids; attacked by HF, hot concentrated HCl/H₂SO₄/phosphoric acid and dry chlorine. Interconnected porosity in Class B can trap electrolyte and cause crevice attack.

Sustainability4

Producing a kilogram of B817 Type I GR2-CLB takes about 750 MJ of energy and emits 48 kg of CO₂ — more than 95% of titanium grades. Typical recycled content is 20%.

Embodied Energy (primary production)750 MJ/kg322,442 BTU/lb
Embodied Carbon (primary production)48 kg CO₂/kg
Embodied Water500 L/kg59.9 gal/lb
Typical Recycled Content20%

Manufacturability7

B817 Type I GR2-CLB's machinability is fair (40/100, better than 93% of titanium grades); weldability fair (45/100); formability fair (35/100).

MachinabilityFair40/100
Machinability Rating (AISI 1212 = 100 %)48%
WeldabilityFair45/100
Formability (cold)Fair35/100
Brazeability / SolderabilityGood60/100
PolishabilityVery good70/100
Anodizing Responseexcellent — Type II/III color anodizing and hard oxide films form readily; residual porosity can retain electrolyte, so Class B parts need thorough rinsing/sealing

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with B817 Type I GR2-CLB

Is B817 Type I easy to machine?

Machine with sharp uncoated-carbide or PVD tools, low surface speed (25–50 m/min), heavy flood coolant and constant feed; porous Class B parts smear and can tear rather than chip.

Can B817 Type I be welded?

GTAW/laser weld only fully densified (Class A / HIP) parts with trailing argon shields and <0.5 % O pickup; porous Class B outgasses and produces weld porosity.

Can B817 Type I be formed, bent or molded?

Parts are net-shape formed by die pressing or metal injection moulding, then debound and vacuum sintered at 1250–1350 °C with 12–20 % linear shrinkage; secondary coining or HIP raises density.

What surface finishes work on B817 Type I?

Excellent anodizing (color or Type II), passivation per ASTM F86, PVD or bead blasting; thoroughly rinse and dry porous Class B parts before anodizing to avoid trapped electrolyte staining.

B817 Type I chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
NP/M interstitial limit; wrought CP-Ti allows 0.03≤ 0.050.02
Cresidual binder/lubricant carbon in MIM≤ 0.10.05
Hvacuum dehydrogenation after sintering≤ 0.020.01
FeGrade 1 ≤0.20; Grade 2 ≤0.30≤ 0.30.15
OGrade 1 lower (≈0.18–0.20); Grade 2 up to ≈0.25–0.30 for P/M≤ 0.30.2
Other, each≤ 0.1—
Other, total≤ 0.4—
Tibalance—

B817 Type I GR2-CLB — frequently asked

What is B817 Type I GR2-CLB used for?

B817 Type I GR2-CLB is typically used for sintered CP-Ti biomedical implants, chemical process fittings, porous filters and diffusers, MIM small hardware and corrosion-resistant sintered parts. In short: net-shape CP titanium; sintered corrosion-resistant parts; class A/B density options.

What is the yield strength of B817 Type I GR2-CLB?

B817 Type I GR2-CLB has a typical yield strength of 300 MPa (43.5 ksi) and a tensile strength of 380 MPa (55.1 ksi) — weaker than 88% of titanium grades. Strength varies by condition: see the 5 listed tempers.

Is B817 Type I GR2-CLB easy to machine?

Not especially — machinability is rated fair (40/100, better than 93% of titanium grades). Machine with sharp uncoated-carbide or PVD tools, low surface speed (25–50 m/min), heavy flood coolant and constant feed; porous Class B parts smear and can tear rather than chip.

Can B817 Type I GR2-CLB be welded?

With care — weldability is rated fair (45/100). GTAW/laser weld only fully densified (Class A / HIP) parts with trailing argon shields and <0.5 % O pickup; porous Class B outgasses and produces weld porosity.

What surface finishes work on B817 Type I GR2-CLB?

Excellent anodizing (color or Type II), passivation per ASTM F86, PVD or bead blasting; thoroughly rinse and dry porous Class B parts before anodizing to avoid trapped electrolyte staining.

Can B817 Type I GR2-CLB be formed, bent or molded?

Parts are net-shape formed by die pressing or metal injection moulding, then debound and vacuum sintered at 1250–1350 °C with 12–20 % linear shrinkage; secondary coining or HIP raises density.

What is the maximum service temperature of B817 Type I GR2-CLB?

B817 Type I GR2-CLB is rated for continuous use to about 280°C (536 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between B817 Type I GR2-CLA and B817 Type I GR1-CLB?

GR2-CLA is the default condition — the workhorse condition: best balance of strength, ductility and corrosion resistance for MIM/HIP CP-Ti parts. GR1-CLB: economy press-and-sinter condition for lightly loaded corrosion-resistant parts where residual porosity is acceptable. Yield strength is 350 MPa in GR2-CLA versus 200 MPa in GR1-CLB.

Sources

  1. ASTM B817 — Powder Metallurgy (P/M) Titanium Alloy Structural Components — ASTM International (2008)
  2. ASTM B348 / ASTM F67 — Unalloyed titanium bar and surgical implant grades — ASTM International (2021)
  3. ASM Handbook Vol. 7 — Powder Metallurgy (Titanium P/M) — ASM International (2015)
  4. ASM Handbook Vol. 2 — Properties of Nonferrous Alloys (Titanium) — ASM International (1990)
  5. MPIF Standard 35 — Materials Standards for Metal Injection Molded Parts — Metal Powder Industries Federation (2018)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.