FabDigitFabDigit

Nickel Alloy N06110 HF-A

Heat-treated state

UNS N06110

HF-A = hot Finished + Annealed

Heavy bar and forged sections annealed after hot work; slightly lower strength scatter than cold-worked stock.

High cost $$$$

Values for the HF-A condition

Other N06110 tempers and conditions

N06110 is listed in 5 conditions; see the grade overview at N06110.

Compare all 5 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
HF-AThis page
Hot Finished + Annealed
Heavy bar and forged sections annealed after hot work; slightly lower strength scatter than cold-worked stock.37077048195 HB1.4 % IACS
SADefault
Solution Annealed
Standard stocked condition for plate, sheet, tube and bar — maximum corrosion resistance and ductility.39079050200 HB—
As-welded deposit
Autogenous or matching-filler GTAW joints used without post-weld solution anneal in most fabrications.42076035195 HB1.4 % IACS
Cold drawn
Pick for higher-strength downhole tooling and fasteners where 120 ksi-class yield is required in sour service.8301,0002232 HRC1.4 % IACS
Heavily Cold Worked, high strength
Maximum-strength condition for springs, wire and small pins; ductility and cold formability are largely exhausted.1,1001,2501240 HRC1.4 % IACS

What is N06110 HF-A?

N06110 HF-A is N06110 heat treated to HF-A — heavy bar and forged sections annealed after hot work; slightly lower strength scatter than cold-worked stock. N06110 HF-A has a yield strength of 370 MPa (53.7 ksi) and a tensile strength of 770 MPa (112 ksi) — weaker than 55% of nickel alloy grades. Elongation at break is 48% and the elastic modulus is 210 GPa (30.5 Msi). N06110 HF-A has a density of 8.4 g/cm³ (0.303 lb/in³), heavier than 57% of nickel alloy grades. It melts at 1,330°C (2,426 °F). SA is the default condition FabDigit quotes; HF-A is available on request or by drawing note.

Advantages

  • Good corrosion resistance — 90/100, better than 85% of nickel alloy grades
  • Ductile — tolerates forming and impact — 48%, better than 83% of nickel alloy grades

Limitations

  • Poor heat conductor — 9 W/m·K (5.2 BTU/hr·ft·°F), worse than 97% of nickel alloy grades

N06110 HF-A properties

Typical room-temperature values for N06110 HF-A; 22 are specific to this condition. Other listed values are N06110 reference data and may not represent this condition. Bars are the position among nickel alloy grades.

Physical3

N06110 HF-A has a density of 8.4 g/cm³ (0.303 lb/in³), heavier than 57% of nickel alloy grades. It melts at 1,330°C (2,426 °F).

Density8.4 g/cm³0.3 lb/in³
Melting Point (Solidus)1,330°C2,426 °F
Liquidus Temperature1,380°C2,516 °F

Mechanical13

N06110 HF-A has a yield strength of 370 MPa (53.7 ksi) and a tensile strength of 770 MPa (112 ksi) — weaker than 55% of nickel alloy grades. Elongation at break is 48% and the elastic modulus is 210 GPa (30.5 Msi).

Elastic (Young's) Modulus210 GPa30.5 Msi
Shear Modulus80 GPa11.6 Msi
Bulk Modulus175 GPa25.4 Msi
Poisson's Ratio0.31
Tensile Strength (Ultimate)770 MPa112 ksi
Yield Strength (0.2% offset)370 MPa53.7 ksi
Elongation at Break48%
Reduction in Area58%
Shear Strength480 MPa69.6 ksi
Fatigue Strength (Endurance Limit)300 MPa43.5 ksi
Charpy V-Notch Impact (RT)200 J148 ft·lbf
Hardness, Brinell195 HB
Hardness, Rockwell B92 HRB

Thermal6

N06110 HF-A is rated for continuous service to 650°C (1,202 °F). It conducts heat at 9 W/m·K (5.2 BTU/hr·ft·°F), worse than 97% of nickel alloy grades. Thermal expansion is 12.3 µm/m·K (6.83 µin/in·°F).

Thermal Conductivity9 W/m·K5.2 BTU/hr·ft·°F
Specific Heat Capacity430 J/kg·K0.1 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)12.3 µm/m·K6.8 µin/in·°F
Latent Heat of Fusion290 J/g125 BTU/lb
Max Service Temperature (continuous)650°C1,202 °F
Min Service Temperature-196°C-321 °F

Electrical3

N06110 HF-A conducts electricity at 1.4 % IACS, worse than 65% of nickel alloy grades.

Electrical Conductivity1.4 % IACS
Electrical Resistivity1.25×10⁻⁶ Ω·m49.2 µΩ·in
Magnetic Responsenon-magnetic

Chemical & Environmental3

Corrosion resistance is excellent (90/100), better than 85% of nickel alloy grades.

Galvanic Potential (seawater, vs SCE)-0.1 V
Corrosion ResistanceExcellent90/100
Chemical Resistance SummaryExcellent in oxidizing acids (HNO3, mixed acids, hot chlorides) thanks to ~31% Cr, and good in reducing media (dilute H2SO4, HCl, H2S brines) thanks to Mo+W; very resistant to chloride pitting, crevice attack and chloride SCC. Limited in hot concentrated HCl and HF; avoid molten sulfur/low-melting metals.

Sustainability4

Producing a kilogram of N06110 HF-A takes about 150 MJ of energy and emits 13 kg of CO₂ — less than 68% of nickel alloy grades. Typical recycled content is 35%.

Embodied Energy (primary production)150 MJ/kg64,488 BTU/lb
Embodied Carbon (primary production)13 kg CO₂/kg
Embodied Water250 L/kg30 gal/lb
Typical Recycled Content35%

Manufacturability8

N06110 HF-A's machinability is poor (16/100, worse than 71% of nickel alloy grades); weldability very good (70/100); formability good (60/100).

MachinabilityPoor16/100
Machinability Rating (AISI 1212 = 100 %)12%
WeldabilityVery good70/100
Formability (cold)Good60/100
CastabilityFair35/100
Brazeability / SolderabilityGood55/100
PolishabilityVery good75/100
Anodizing Responsen/a — nickel alloy; use pickling/passivation or electropolishing instead of anodizing

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with N06110 HF-A

Is N06110 easy to machine?

Machine like alloy C-276: rigid setup, positive-rake sharp carbide, low surface speed (~15–25 m/min), heavy constant feed to cut under the work-hardened layer, and flood high-pressure coolant.

Can N06110 be welded?

Readily GTAW/GMAW/PAW welded with matching or over-alloyed Ni-Cr-Mo filler; low heat input, interpass <150 °C, no preheat or PWHT, and remove heat tint by pickling to restore passivity.

Can N06110 be formed, bent or molded?

Cold forms well in the annealed state but work-hardens rapidly — allow generous bend radii and interstage solution anneals; hot work 1150–950 °C followed by rapid water quench.

What surface finishes work on N06110?

Pickle/passivate or electropolish after fabrication; not anodizable — for wear surfaces use nitriding-free coatings such as HVOF carbide or electroless nickel.

N06110 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
Crhigh Cr for oxidizing acid and pitting resistance30 – 3331
Mo9 – 1110
W1.5 – 3.53
Feresidual≤ 61
Co≤ 2—
Mn≤ 10.3
Si≤ 10.3
Al≤ 0.50.2
Ti≤ 0.50.2
C≤ 0.050.02
P≤ 0.03—
S≤ 0.02—
Nibalance, nominally ~54%balance—

N06110 HF-A — frequently asked

What is N06110 HF-A used for?

N06110 HF-A is typically used for furnace and heat-treatment components, high-temperature fasteners and process industry fixtures. In short: high-strength Ni-Cr-Fe grade; corrosion score 90; 650 °C service limit.

What is the yield strength of N06110 HF-A?

N06110 HF-A has a typical yield strength of 370 MPa (53.7 ksi) and a tensile strength of 770 MPa (112 ksi) — weaker than 55% of nickel alloy grades. Strength varies by condition: see the 5 listed tempers.

Is N06110 HF-A easy to machine?

Not especially — machinability is rated poor (16/100, worse than 71% of nickel alloy grades). Machine like alloy C-276: rigid setup, positive-rake sharp carbide, low surface speed (~15–25 m/min), heavy constant feed to cut under the work-hardened layer, and flood high-pressure coolant.

Can N06110 HF-A be welded?

Yes — weldability is rated very good (70/100). Readily GTAW/GMAW/PAW welded with matching or over-alloyed Ni-Cr-Mo filler; low heat input, interpass <150 °C, no preheat or PWHT, and remove heat tint by pickling to restore passivity.

What surface finishes work on N06110 HF-A?

Pickle/passivate or electropolish after fabrication; not anodizable — for wear surfaces use nitriding-free coatings such as HVOF carbide or electroless nickel.

Can N06110 HF-A be formed, bent or molded?

Cold forms well in the annealed state but work-hardens rapidly — allow generous bend radii and interstage solution anneals; hot work 1150–950 °C followed by rapid water quench.

What is the maximum service temperature of N06110 HF-A?

N06110 HF-A is rated for continuous use to about 650°C (1,202 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between N06110-SA and N06110 CW-HS?

SA is the default condition — standard stocked condition for plate, sheet, tube and bar — maximum corrosion resistance and ductility. CW-HS: maximum-strength condition for springs, wire and small pins; ductility and cold formability are largely exhausted. Yield strength is 390 MPa in SA versus 1,100 MPa in CW-HS.

Sources

  1. ASM Handbook Vol. 2 — Properties and Selection: Nonferrous Alloys and Special-Purpose Materials (Ni-Cr-Mo corrosion-resistant alloys) — ASM International (1990)
  2. ASTM B575 / B574 / B622 — Ni-Cr-Mo alloy plate, sheet, strip, bar and tube (family standards) — ASTM International (2022)
  3. UNS Metals & Alloys in the Unified Numbering System (N06110 registration) — SAE/ASTM (2017)
  4. Ni-Cr-Mo-W corrosion-resistant alloy bar data (ALLCORR-type) — specialty alloy producer (2020)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.