FabDigitFabDigit

Steel 6145-A (Solution annealed)

Temper · default condition

AISI/SAE 6145 · UNS G61450

Softest, most machinable condition; the normal supply state for bar that will be machined then quenched and tempered.

Budget cost $

Values for the A condition

Other 6145 tempers and conditions

6145 is listed in 10 conditions; see the grade overview at 6145.

Compare all 10 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
ADefaultThis page
Solution annealed
Softest, most machinable condition; the normal supply state for bar that will be machined then quenched and tempered.42067022197 HB—
Hot rolled
As-rolled mill condition; cheapest stock for parts that will be re-heat-treated after machining.46076018217 HB—
Normalized
Uniform fine pearlitic structure for forgings before machining or final hardening; higher strength than annealed.6159401827 HRC—
Cold drawn
Tight-tolerance bright bar with raised yield strength; pick for as-machined parts not needing heat treatment.69079012229 HB—
Q&T 28–32 HRC
Tough general-purpose machine condition for shafts and highly stressed structural parts.9001,0001830 HRC—
Q&T 34–38 HRC
Balanced strength/toughness for torsion bars, gear blanks and heavy-duty fasteners.1,0801,1801536 HRC—
Q&T 40–44 HRC
High-strength condition for leaf/coil springs, punches and heavily loaded shafts.1,2801,4001242 HRC—
Q&T 46–50 HRC
Classic spring/torsion-bar temper with maximum elastic limit at usable toughness.1,4801,6201048 HRC—
Q&T 52–54 HRC
Maximum strength temper for hand tools and wear parts; notch-sensitive, avoid stress raisers.1,6501,830853 HRC—
As-quenched
Intermediate process state only — must be tempered promptly; brittle and prone to quench cracking.1,6502,100259 HRC6.6 % IACS

What is 6145-A?

6145-A is 6145 in the A temper — softest, most machinable condition; the normal supply state for bar that will be machined then quenched and tempered. 6145-A has a yield strength of 420 MPa (60.9 ksi) and a tensile strength of 670 MPa (97.2 ksi) — weaker than 53% of steel grades. Elongation at break is 22% and the elastic modulus is 205 GPa (29.7 Msi). 6145-A has a density of 7.85 g/cm³ (0.284 lb/in³), heavier than 56% of steel grades. It melts at 1,420°C (2,588 °F).

6145-A properties

Typical room-temperature values for 6145-A; 16 are specific to this condition. Other listed values are 6145 reference data and may not represent this condition. Bars are the position among steel grades.

Physical3

6145-A has a density of 7.85 g/cm³ (0.284 lb/in³), heavier than 56% of steel grades. It melts at 1,420°C (2,588 °F).

Density7.85 g/cm³0.28 lb/in³
Melting Point (Solidus)1,420°C2,588 °F
Liquidus Temperature1,490°C2,714 °F

Mechanical16

6145-A has a yield strength of 420 MPa (60.9 ksi) and a tensile strength of 670 MPa (97.2 ksi) — weaker than 53% of steel grades. Elongation at break is 22% and the elastic modulus is 205 GPa (29.7 Msi).

Elastic (Young's) Modulus205 GPa29.7 Msi
Shear Modulus80 GPa11.6 Msi
Bulk Modulus160 GPa23.2 Msi
Poisson's Ratio0.29
Tensile Strength (Ultimate)670 MPa97.2 ksi
Yield Strength (0.2% offset)420 MPa60.9 ksi
Elongation at Break22%
Reduction in Area50%
Compressive Strength420 MPa60.9 ksi
Shear Strength440 MPa63.8 ksi
Fatigue Strength (Endurance Limit)310 MPa45 ksi
Fracture Toughness (K_IC)90 MPa·√m81.9 ksi·√in
Charpy V-Notch Impact (RT)40 J29.5 ft·lbf
Hardness, Brinell197 HB
Hardness, Rockwell B92 HRB
Hardness, Vickers207 HV

Thermal6

6145-A is rated for continuous service to 400°C (752 °F). It conducts heat at 45 W/m·K (26 BTU/hr·ft·°F), better than 66% of steel grades. Thermal expansion is 12.2 µm/m·K (6.78 µin/in·°F).

Thermal Conductivity45 W/m·K26 BTU/hr·ft·°F
Specific Heat Capacity475 J/kg·K0.11 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)12.2 µm/m·K6.8 µin/in·°F
Latent Heat of Fusion270 J/g116 BTU/lb
Max Service Temperature (continuous)400°C752 °F
Min Service Temperature-40°C-40 °F

Electrical3

6145-A conducts electricity at 7.5 % IACS, worse than 67% of steel grades.

Electrical Conductivity7.5 % IACS
Electrical Resistivity2.3×10⁻⁷ Ω·m9.06 µΩ·in
Magnetic Responseferromagnetic

Chemical & Environmental3

Corrosion resistance is not recommended (12/100), worse than 53% of steel grades.

Galvanic Potential (seawater, vs SCE)-0.61 V
Corrosion ResistanceNot recommended12/100
Chemical Resistance SummaryRusts freely in humid air, water and salt spray; attacked by dilute acids; resists dry hydrocarbons, oils and greases. Requires oil, phosphate, black-oxide, zinc plating or paint for storage and service.

Sustainability4

Producing a kilogram of 6145-A takes about 29 MJ of energy and emits 2.1 kg of CO₂ — less than 53% of steel grades. Typical recycled content is 30%.

Embodied Energy (primary production)29 MJ/kg12,468 BTU/lb
Embodied Carbon (primary production)2.1 kg CO₂/kg
Embodied Water60 L/kg7.2 gal/lb
Typical Recycled Content30%

Manufacturability7

6145-A's machinability is fair (52/100, better than 52% of steel grades); weldability poor (30/100); formability fair (45/100).

MachinabilityFair52/100
Machinability Rating (AISI 1212 = 100 %)55%
WeldabilityPoor30/100
Formability (cold)Fair45/100
Brazeability / SolderabilityGood55/100
PolishabilityGood60/100
Anodizing Responsen/a — ferrous alloy; use black oxide, phosphate, zinc or Zn-Ni plating instead

Common Calculations5

Specific Strength (UTS / density)calculated85 kN·m/kg
Specific Stiffness (E / density)calculated26.1 MN·m/kg
Modulus of Resiliencecalculated430 kJ/m³
Thermal Diffusivitycalculated12.1 mm²/s
Thermal Shock Resistance Indexcalculated12

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with 6145-A

Is 6145 easy to machine?

Machine in the annealed or ≤32 HRC condition with rigid setups, carbide tooling and generous coolant; above 40 HRC switch to grinding or CBN.

Can 6145 be welded?

Poor weldability (CE ≈0.85): preheat 250–350 °C, use low-hydrogen consumables, and temper immediately after welding to avoid martensitic cracking.

Can 6145 be formed, bent or molded?

Cold-form or coil only in the annealed state; springs are usually hot-coiled or coiled from annealed bar then quenched and tempered, with stress relief after coiling.

What surface finishes work on 6145?

No anodizing — protect with black oxide, phosphate + oil, zinc or Zn-Ni plating (bake at 190–220 °C for hydrogen relief); shot peening markedly raises spring fatigue life.

6145 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
C0.43 – 0.480.46
Mn0.7 – 0.90.8
Si0.15 – 0.350.25
Cr0.8 – 1.10.95
V0.15 % minimum per SAE J404≥ 0.150.18
P≤ 0.04—
S≤ 0.04—
Febalance—

6145-A — frequently asked

What is 6145-A used for?

6145-A is typically used for springs, shafts and high-strength fasteners. In short: higher hardenability than 6120; cr-V spring and shaft steel; poor weldability.

What is the yield strength of 6145-A?

6145-A has a typical yield strength of 420 MPa (60.9 ksi) and a tensile strength of 670 MPa (97.2 ksi) — weaker than 53% of steel grades. Strength varies by condition: see the 10 listed tempers.

Is 6145-A easy to machine?

Reasonably — machinability is rated fair (52/100, better than 52% of steel grades). Machine in the annealed or ≤32 HRC condition with rigid setups, carbide tooling and generous coolant; above 40 HRC switch to grinding or CBN.

Can 6145-A be welded?

Not readily — weldability is rated poor (30/100). Poor weldability (CE ≈0.85): preheat 250–350 °C, use low-hydrogen consumables, and temper immediately after welding to avoid martensitic cracking.

What surface finishes work on 6145-A?

No anodizing — protect with black oxide, phosphate + oil, zinc or Zn-Ni plating (bake at 190–220 °C for hydrogen relief); shot peening markedly raises spring fatigue life.

Can 6145-A be formed, bent or molded?

Cold-form or coil only in the annealed state; springs are usually hot-coiled or coiled from annealed bar then quenched and tempered, with stress relief after coiling.

What is the maximum service temperature of 6145-A?

6145-A is rated for continuous use to about 400°C (752 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between 6145-A and 6145 QT52-54?

A is the default condition — softest, most machinable condition; the normal supply state for bar that will be machined then quenched and tempered. QT52-54: maximum strength temper for hand tools and wear parts; notch-sensitive, avoid stress raisers. Yield strength is 420 MPa in A versus 1,650 MPa in QT52-54.

Sources

  1. SAE J404 — Chemical Compositions of SAE Alloy Steels — SAE International (2021)
  2. ASTM A29/A29M — Steel Bars, Carbon and Alloy, Hot-Wrought — ASTM (2020)
  3. ASM Handbook Vol.1 — Properties and Selection: Irons, Steels, and High-Performance Alloys — ASM International (1990)
  4. ASM Handbook Vol.4 — Heat Treating — ASM International (1991)
  5. Machinery's Handbook, 31st ed. — Industrial Press (2020)
  6. GB/T 1222 (50CrVA) — SAC (2016)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.