FabDigitFabDigit

Titanium Grade C-3-HIP (Hot isostatic pressed)

Print state

ASTM B367 Grade C-3

Choose for fatigue-loaded, pressure-boundary or medical castings where internal porosity must be closed.

High cost $$$$

Values for the HIP condition

Other Grade C-3 tempers and conditions

Grade C-3 is listed in 4 conditions; see the grade overview at Grade C-3.

Compare all 4 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
Stress relieved
Use after heavy weld repair or rough machining to remove residual stress and stabilise dimensions.5056051622 HRC3.1 % IACS
HIP + anneal
Best ductility/toughness combination for critical aerospace or implant-grade CP-Ti castings.5106152022 HRC3.1 % IACS
FDefault
As fabricated
Standard supply condition for non-critical corrosion hardware where residual microporosity is acceptable.52062014250 HB—
HIPThis page
Hot isostatic pressed
Choose for fatigue-loaded, pressure-boundary or medical castings where internal porosity must be closed.52563018245 HB—

What is Grade C-3-HIP?

Grade C-3-HIP is Grade C-3 in the HIP condition — choose for fatigue-loaded, pressure-boundary or medical castings where internal porosity must be closed. Grade C-3-HIP has a yield strength of 525 MPa (76.1 ksi) and a tensile strength of 630 MPa (91.4 ksi) — weaker than 59% of titanium grades. Elongation at break is 18% and the elastic modulus is 104 GPa (15.1 Msi). Grade C-3-HIP has a density of 4.51 g/cm³ (0.163 lb/in³), heavier than 57% of titanium grades. It melts at 1,650°C (3,002 °F). F is the default condition FabDigit quotes; HIP is available on request or by drawing note.

Advantages

  • Conducts heat well — 17.2 W/m·K (9.94 BTU/hr·ft·°F), better than 88% of titanium grades
  • High service temperature — 400°C (752 °F), better than 78% of titanium grades
  • High electrical conductivity — 3.1 % IACS, better than 75% of titanium grades

Grade C-3-HIP properties

Typical room-temperature values for Grade C-3-HIP; 11 are specific to this condition. Other listed values are Grade C-3 reference data and may not represent this condition. Bars are the position among titanium grades.

Physical3

Grade C-3-HIP has a density of 4.51 g/cm³ (0.163 lb/in³), heavier than 57% of titanium grades. It melts at 1,650°C (3,002 °F).

Density4.51 g/cm³0.16 lb/in³
Melting Point (Solidus)1,650°C3,002 °F
Liquidus Temperature1,665°C3,029 °F

Mechanical16

Grade C-3-HIP has a yield strength of 525 MPa (76.1 ksi) and a tensile strength of 630 MPa (91.4 ksi) — weaker than 59% of titanium grades. Elongation at break is 18% and the elastic modulus is 104 GPa (15.1 Msi).

Elastic (Young's) Modulus104 GPa15.1 Msi
Shear Modulus41 GPa5.9 Msi
Bulk Modulus110 GPa16 Msi
Poisson's Ratio0.34
Tensile Strength (Ultimate)630 MPa91.4 ksi
Yield Strength (0.2% offset)525 MPa76.1 ksi
Elongation at Break18%
Reduction in Area32%
Compressive Strength620 MPa89.9 ksi
Shear Strength400 MPa58 ksi
Fatigue Strength (Endurance Limit)330 MPa47.9 ksi
Fracture Toughness (K_IC)70 MPa·√m63.7 ksi·√in
Charpy V-Notch Impact (RT)22 J16.2 ft·lbf
Hardness, Brinell245 HB
Hardness, Rockwell C24 HRC
Hardness, Vickers255 HV

Thermal6

Grade C-3-HIP is rated for continuous service to 400°C (752 °F). It conducts heat at 17.2 W/m·K (9.94 BTU/hr·ft·°F), better than 88% of titanium grades. Thermal expansion is 8.6 µm/m·K (4.78 µin/in·°F).

Thermal Conductivity17.2 W/m·K9.9 BTU/hr·ft·°F
Specific Heat Capacity540 J/kg·K0.13 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)8.6 µm/m·K4.8 µin/in·°F
Latent Heat of Fusion365 J/g157 BTU/lb
Max Service Temperature (continuous)400°C752 °F
Min Service Temperature-196°C-321 °F

Electrical3

Grade C-3-HIP conducts electricity at 3.1 % IACS, better than 75% of titanium grades.

Electrical Conductivity3.1 % IACS
Electrical Resistivity5.6×10⁻⁷ Ω·m22 µΩ·in
Magnetic Responsenon-magnetic

Chemical & Environmental3

Corrosion resistance is excellent (93/100), better than 72% of titanium grades.

Galvanic Potential (seawater, vs SCE)-0.1 V
Corrosion ResistanceExcellent93/100
Chemical Resistance SummaryExcellent in seawater, wet chlorine, hypochlorite, nitric acid and most oxidizing/neutral media thanks to a stable TiO₂ film; attacked by HF, hot concentrated HCl/H₂SO₄, and dry chlorine; risk of hydriding in reducing hydrogen-bearing service.

Sustainability4

Producing a kilogram of Grade C-3-HIP takes about 700 MJ of energy and emits 45 kg of CO₂ — more than 74% of titanium grades. Typical recycled content is 30%.

Embodied Energy (primary production)700 MJ/kg300,946 BTU/lb
Embodied Carbon (primary production)45 kg CO₂/kg
Embodied Water550 L/kg65.9 gal/lb
Typical Recycled Content30%

Manufacturability8

Grade C-3-HIP's machinability is poor (32/100, better than 70% of titanium grades); weldability very good (82/100); formability poor (25/100).

MachinabilityPoor32/100
Machinability Rating (AISI 1212 = 100 %)25%
WeldabilityVery good82/100
Formability (cold)Poor25/100
CastabilityGood60/100
Brazeability / SolderabilityFair40/100
PolishabilityVery good70/100
Anodizing Responseexcellent — Type II/III titanium anodizing gives colored interference oxide films and improved bio/wear surfaces; not a hard-coat like aluminum

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with Grade C-3-HIP

Is Grade C-3 easy to machine?

Machine with sharp uncoated-carbide or PVD tools, low surface speed (~30–50 m/min), heavy positive rake, rigid setup and flood coolant; never dwell, and control chip fire risk.

Can Grade C-3 be welded?

Readily GTAW/EBW/plasma welded to itself with matching or lower-oxygen filler under full argon/helium shielding including trailing and back purge; keep weld colour silver, avoid any contamination for weld repair per AWS D17.1.

Can Grade C-3 be formed, bent or molded?

Supplied as investment or rammed-graphite castings poured in vacuum/inert atmosphere; allow generous fillets and feeders, and specify HIP for pressure-tight or fatigue-critical parts — cold forming is not applicable.

What surface finishes work on Grade C-3?

Chemical mill/pickle in HNO₃–HF to remove the alpha case, then bead blast, polish or colour-anodize; avoid iron contamination from steel tooling to preserve corrosion resistance.

Grade C-3 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
N≤ 0.050.02
C≤ 0.10.03
H≤ 0.020.01
Fe≤ 0.40.25
Oprincipal strengthener; higher than C-1/C-2≤ 0.40.32
Residuals (each)each, max≤ 0.1—
Residuals (total)total, max≤ 0.4—
Tibalance—

Grade C-3-HIP — frequently asked

What is Grade C-3-HIP used for?

Grade C-3-HIP is typically used for aerospace brackets, marine fittings, surgical instrument castings and industrial valve trim. In short: strongest unalloyed cast titanium; corrosion score 93; step up from C-2.

What is the yield strength of Grade C-3-HIP?

Grade C-3-HIP has a typical yield strength of 525 MPa (76.1 ksi) and a tensile strength of 630 MPa (91.4 ksi) — weaker than 59% of titanium grades. Strength varies by condition: see the 4 listed tempers.

Is Grade C-3-HIP easy to machine?

Not especially — machinability is rated poor (32/100, better than 70% of titanium grades). Machine with sharp uncoated-carbide or PVD tools, low surface speed (~30–50 m/min), heavy positive rake, rigid setup and flood coolant; never dwell, and control chip fire risk.

Can Grade C-3-HIP be welded?

Yes — weldability is rated very good (82/100). Readily GTAW/EBW/plasma welded to itself with matching or lower-oxygen filler under full argon/helium shielding including trailing and back purge; keep weld colour silver, avoid any contamination for weld repair per AWS D17.1.

What surface finishes work on Grade C-3-HIP?

Chemical mill/pickle in HNO₃–HF to remove the alpha case, then bead blast, polish or colour-anodize; avoid iron contamination from steel tooling to preserve corrosion resistance.

Can Grade C-3-HIP be formed, bent or molded?

Supplied as investment or rammed-graphite castings poured in vacuum/inert atmosphere; allow generous fillets and feeders, and specify HIP for pressure-tight or fatigue-critical parts — cold forming is not applicable.

What is the maximum service temperature of Grade C-3-HIP?

Grade C-3-HIP is rated for continuous use to about 400°C (752 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between Grade C-3-F and Grade C-3-SR?

F is the default condition — standard supply condition for non-critical corrosion hardware where residual microporosity is acceptable. SR: use after heavy weld repair or rough machining to remove residual stress and stabilise dimensions. Yield strength is 520 MPa in F versus 505 MPa in SR.

Sources

  1. ASTM B367 — Standard Specification for Titanium and Titanium Alloy Castings — ASTM International (2022)
  2. ASTM B265 / ASTM F67 (wrought CP-Ti Grade 4 reference values) — ASTM International (2020)
  3. ASM Handbook Vol. 2 — Properties and Selection: Nonferrous Alloys — ASM International (1990)
  4. ASM Handbook Vol. 13B — Corrosion: Materials (Titanium) — ASM International (2005)
  5. Materials Properties Handbook: Titanium Alloys — ASM International (1994)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.