FabDigitFabDigit

Steel E71T-8-H8

Grade

Order this designator when hydrogen-assisted cracking control is specified for higher-restraint or thicker carbon/low-alloy joints.

Standard cost $$

Values for the H8 condition

Other E71T-8 tempers and conditions

E71T-8 is listed in 4 conditions; see the grade overview at E71T-8.

Compare all 4 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
Stress relieved
Pick when the fabrication code requires PWHT of thick or restrained joints; strength drops slightly, ductility rises.43052029160 HB10.5 % IACS
AWDefault
As-welded deposit
Standard condition for AWS A5.20 classification testing and for the great majority of field structural work.46055026170 HB—
H8This page
E71T-8-H8
Order this designator when hydrogen-assisted cracking control is specified for higher-restraint or thicker carbon/low-alloy joints.46055026170 HB10 % IACS
E71T8-Ni1J
Use for cold-service structures where 27 J is required at -40 °C rather than -29 °C.48057025180 HB9 % IACS

What is E71T-8-H8?

E71T-8-H8 is E71T-8 in the H8 grade — order this designator when hydrogen-assisted cracking control is specified for higher-restraint or thicker carbon/low-alloy joints. E71T-8-H8 has a yield strength of 460 MPa (66.7 ksi) and a tensile strength of 550 MPa (79.8 ksi) — stronger than 55% of steel grades. Elongation at break is 26% and the elastic modulus is 205 GPa (29.7 Msi). E71T-8-H8 has a density of 7.85 g/cm³ (0.284 lb/in³), heavier than 56% of steel grades. It melts at 1,460°C (2,660 °F). AW is the default condition FabDigit quotes; H8 is available on request or by drawing note.

Advantages

  • Readily welded — 92/100, better than 93% of steel grades
  • High electrical conductivity — 10 % IACS, better than 83% of steel grades
  • Ductile — tolerates forming and impact — 26%, better than 82% of steel grades
  • Conducts heat well — 48 W/m·K (27.7 BTU/hr·ft·°F), better than 79% of steel grades

Limitations

  • Hard to polish — 45/100, worse than 84% of steel grades

E71T-8-H8 properties

Typical room-temperature values for E71T-8-H8; 22 are specific to this condition. Other listed values are E71T-8 reference data and may not represent this condition. Bars are the position among steel grades.

Physical3

E71T-8-H8 has a density of 7.85 g/cm³ (0.284 lb/in³), heavier than 56% of steel grades. It melts at 1,460°C (2,660 °F).

Density7.85 g/cm³0.28 lb/in³
Melting Point (Solidus)1,460°C2,660 °F
Liquidus Temperature1,520°C2,768 °F

Mechanical14

E71T-8-H8 has a yield strength of 460 MPa (66.7 ksi) and a tensile strength of 550 MPa (79.8 ksi) — stronger than 55% of steel grades. Elongation at break is 26% and the elastic modulus is 205 GPa (29.7 Msi).

Elastic (Young's) Modulus205 GPa29.7 Msi
Shear Modulus79 GPa11.5 Msi
Bulk Modulus160 GPa23.2 Msi
Poisson's Ratio0.29
Tensile Strength (Ultimate)550 MPa79.8 ksi
Yield Strength (0.2% offset)460 MPa66.7 ksi
Elongation at Break26%
Reduction in Area55%
Shear Strength340 MPa49.3 ksi
Fatigue Strength (Endurance Limit)220 MPa31.9 ksi
Charpy V-Notch Impact (RT)85 J62.7 ft·lbf
Hardness, Brinell170 HB
Hardness, Rockwell B88 HRB
Hardness, Vickers180 HV

Thermal6

E71T-8-H8 is rated for continuous service to 400°C (752 °F). It conducts heat at 48 W/m·K (27.7 BTU/hr·ft·°F), better than 79% of steel grades. Thermal expansion is 12.5 µm/m·K (6.94 µin/in·°F).

Thermal Conductivity48 W/m·K27.7 BTU/hr·ft·°F
Specific Heat Capacity470 J/kg·K0.11 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)12.5 µm/m·K6.9 µin/in·°F
Latent Heat of Fusion270 J/g116 BTU/lb
Max Service Temperature (continuous)400°C752 °F
Min Service Temperature-40°C-40 °F

Electrical3

E71T-8-H8 conducts electricity at 10 % IACS, better than 83% of steel grades.

Electrical Conductivity10 % IACS
Electrical Resistivity1.7×10⁻⁷ Ω·m6.69 µΩ·in
Magnetic Responseferromagnetic

Chemical & Environmental3

Corrosion resistance is not recommended (12/100), worse than 53% of steel grades.

Galvanic Potential (seawater, vs SCE)-0.65 V
Corrosion ResistanceNot recommended12/100
Chemical Resistance SummaryNo inherent corrosion resistance; rusts in humid/marine service and must be painted, metallized or galvanized. Resists dry hydrocarbons and neutral oils; attacked by acids, chlorides and wet CO2.

Sustainability4

Producing a kilogram of E71T-8-H8 takes about 32 MJ of energy and emits 2.4 kg of CO₂ — more than 70% of steel grades. Typical recycled content is 30%.

Embodied Energy (primary production)32 MJ/kg13,758 BTU/lb
Embodied Carbon (primary production)2.4 kg CO₂/kg
Embodied Water60 L/kg7.2 gal/lb
Typical Recycled Content30%

Manufacturability7

E71T-8-H8's machinability is good (55/100, better than 62% of steel grades); weldability excellent (92/100); formability good (55/100).

MachinabilityGood55/100
Machinability Rating (AISI 1212 = 100 %)60%
WeldabilityExcellent92/100
Formability (cold)Good55/100
Brazeability / SolderabilityGood60/100
PolishabilityFair45/100
Anodizing Responsen/a — ferrous weld metal; use paint, zinc metallizing or hot-dip galvanizing for protection

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with E71T-8-H8

Is E71T-8 easy to machine?

Deposit machines like a normalized C-Mn steel (~60 % of AISI 1212); remove slag and any Al-rich oxide skin before cutting to protect tool edges.

Can E71T-8 be welded?

Self-shielded DCEN, all-position, no shielding gas — ideal for windy field work; keep interpass ≤250 °C and stringer/slight-weave technique, and remove slag fully between passes to avoid inclusions.

Can E71T-8 be formed, bent or molded?

Wire is drawn and rolled into a formed strip sheath with mineral flux fill; keep spools dry (re-bake per maker) to hold low diffusible hydrogen.

What surface finishes work on E71T-8?

Weld beads must be de-slagged and ground before painting; no anodizing — protect with epoxy paint, zinc-rich primer, metallizing or galvanizing.

E71T-8 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
CAWS A5.20 weld-metal limit; typical deposit much lower≤ 0.30.08
Mn≤ 1.750.9
Si≤ 0.60.15
P≤ 0.030.01
S≤ 0.030.01
AlAluminium deoxidiser characteristic of self-shielded T-8 slag system≤ 1.81
Niup to ~1.2 % in the Ni1J variant≤ 0.50.1
Cr≤ 0.20.03
Mo≤ 0.30.02
V≤ 0.080.01
Febalance—

E71T-8-H8 — frequently asked

What is E71T-8-H8 used for?

E71T-8-H8 is typically used for structural steel in cold climates, field erection and bridge construction. In short: gasless with cold toughness; all-position self-shielded wire; low-hydrogen H8 variants.

What is the yield strength of E71T-8-H8?

E71T-8-H8 has a typical yield strength of 460 MPa (66.7 ksi) and a tensile strength of 550 MPa (79.8 ksi) — stronger than 55% of steel grades. Strength varies by condition: see the 4 listed tempers.

Is E71T-8-H8 easy to machine?

Reasonably — machinability is rated good (55/100, better than 62% of steel grades). Deposit machines like a normalized C-Mn steel (~60 % of AISI 1212); remove slag and any Al-rich oxide skin before cutting to protect tool edges.

Can E71T-8-H8 be welded?

Yes — weldability is rated excellent (92/100). Self-shielded DCEN, all-position, no shielding gas — ideal for windy field work; keep interpass ≤250 °C and stringer/slight-weave technique, and remove slag fully between passes to avoid inclusions.

What surface finishes work on E71T-8-H8?

Weld beads must be de-slagged and ground before painting; no anodizing — protect with epoxy paint, zinc-rich primer, metallizing or galvanizing.

Can E71T-8-H8 be formed, bent or molded?

Wire is drawn and rolled into a formed strip sheath with mineral flux fill; keep spools dry (re-bake per maker) to hold low diffusible hydrogen.

What is the maximum service temperature of E71T-8-H8?

E71T-8-H8 is rated for continuous use to about 400°C (752 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between E71T-8-AW and E71T-8-SR?

AW is the default condition — standard condition for AWS A5.20 classification testing and for the great majority of field structural work. SR: pick when the fabrication code requires PWHT of thick or restrained joints; strength drops slightly, ductility rises. Yield strength is 460 MPa in AW versus 430 MPa in SR.

Sources

  1. AWS A5.20/A5.20M — Specification for Carbon Steel Electrodes for Flux Cored Arc Welding — American Welding Society (2015)
  2. ASM Handbook Vol.6 — Welding, Brazing and Soldering — ASM International (1993)
  3. ASM Handbook Vol.1 — Properties and Selection: Irons, Steels — ASM International (1990)
  4. Self-shielded flux-cored wire datasheets (Lincoln Electric NR-series, Hobart, / E71T-8) — various producers (2024)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.