FabDigitFabDigit

Steel E70C-Ni2 AW-C

Finish state

UNS W22030

AW-C = as-welded, 100 % CO₂ shielding

Pick for lower gas cost and deeper penetration; slightly lower deposit toughness and more spatter than mixed gas.

Standard cost $$

Values for the AW-C condition

Other E70C-Ni2 tempers and conditions

E70C-Ni2 is listed in 4 conditions; see the grade overview at E70C-Ni2.

Compare all 4 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
Post-weld heat treated
Pick when the fabrication code requires stress relief: strength drops slightly, ductility and dimensional stability improve.43052029160 HB8.8 % IACS
AW-CThis page
As-welded, 100 % CO₂ shielding
Pick for lower gas cost and deeper penetration; slightly lower deposit toughness and more spatter than mixed gas.46055026172 HB8.5 % IACS
AWDefault
As-welded deposit
Default condition: properties of the deposit straight off the arc, no post-weld heat treatment.47056027175 HB8.6 % IACS
As-welded, 75–80 % Ar / balance CO₂ shielding
Pick when mixed-gas shielding is used — slightly higher strength and the best low-temperature toughness with low spatter.48057028178 HB8.6 % IACS

What is E70C-Ni2 AW-C?

E70C-Ni2 AW-C is E70C-Ni2 supplied in the AW-C condition — pick for lower gas cost and deeper penetration; slightly lower deposit toughness and more spatter than mixed gas. E70C-Ni2 AW-C has a yield strength of 460 MPa (66.7 ksi) and a tensile strength of 550 MPa (79.8 ksi) — stronger than 55% of steel grades. Elongation at break is 26% and the elastic modulus is 205 GPa (29.7 Msi). E70C-Ni2 AW-C has a density of 7.85 g/cm³ (0.284 lb/in³), heavier than 56% of steel grades. It melts at 1,460°C (2,660 °F). AW is the default condition FabDigit quotes; AW-C is available on request or by drawing note.

Advantages

  • Readily welded — 92/100, better than 93% of steel grades
  • Ductile — tolerates forming and impact — 26%, better than 82% of steel grades

Limitations

  • Hard to polish — 45/100, worse than 84% of steel grades

E70C-Ni2 AW-C properties

Typical room-temperature values for E70C-Ni2 AW-C; 22 are specific to this condition. Other listed values are E70C-Ni2 reference data and may not represent this condition. Bars are the position among steel grades.

Physical3

E70C-Ni2 AW-C has a density of 7.85 g/cm³ (0.284 lb/in³), heavier than 56% of steel grades. It melts at 1,460°C (2,660 °F).

Density7.85 g/cm³0.28 lb/in³
Melting Point (Solidus)1,460°C2,660 °F
Liquidus Temperature1,515°C2,759 °F

Mechanical16

E70C-Ni2 AW-C has a yield strength of 460 MPa (66.7 ksi) and a tensile strength of 550 MPa (79.8 ksi) — stronger than 55% of steel grades. Elongation at break is 26% and the elastic modulus is 205 GPa (29.7 Msi).

Elastic (Young's) Modulus205 GPa29.7 Msi
Shear Modulus80 GPa11.6 Msi
Bulk Modulus160 GPa23.2 Msi
Poisson's Ratio0.29
Tensile Strength (Ultimate)550 MPa79.8 ksi
Yield Strength (0.2% offset)460 MPa66.7 ksi
Elongation at Break26%
Reduction in Area63%
Compressive Strength465 MPa67.4 ksi
Shear Strength335 MPa48.6 ksi
Fatigue Strength (Endurance Limit)225 MPa32.6 ksi
Fracture Toughness (K_IC)95 MPa·√m86.5 ksi·√in
Charpy V-Notch Impact (RT)115 J84.8 ft·lbf
Hardness, Brinell172 HB
Hardness, Rockwell B86 HRB
Hardness, Vickers180 HV

Thermal6

E70C-Ni2 AW-C is rated for continuous service to 400°C (752 °F). It conducts heat at 38 W/m·K (22 BTU/hr·ft·°F), worse than 69% of steel grades. Thermal expansion is 12.3 µm/m·K (6.83 µin/in·°F).

Thermal Conductivity38 W/m·K22 BTU/hr·ft·°F
Specific Heat Capacity470 J/kg·K0.11 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)12.3 µm/m·K6.8 µin/in·°F
Latent Heat of Fusion270 J/g116 BTU/lb
Max Service Temperature (continuous)400°C752 °F
Min Service Temperature-50°C-58 °F

Electrical3

E70C-Ni2 AW-C conducts electricity at 8.5 % IACS, better than 63% of steel grades.

Electrical Conductivity8.5 % IACS
Electrical Resistivity2.03×10⁻⁷ Ω·m7.99 µΩ·in
Magnetic Responseferromagnetic

Chemical & Environmental2

Corrosion resistance is not recommended (12/100), worse than 53% of steel grades.

Corrosion ResistanceNot recommended12/100
Chemical Resistance SummaryRusts freely in humid air and water; requires coating or cathodic protection. Not resistant to acids, chlorides or seawater; slightly better atmospheric behaviour than plain C-Mn weld metal because of the Ni addition.

Sustainability4

Producing a kilogram of E70C-Ni2 AW-C takes about 32 MJ of energy and emits 2.4 kg of CO₂ — more than 70% of steel grades. Typical recycled content is 25%.

Embodied Energy (primary production)32 MJ/kg13,758 BTU/lb
Embodied Carbon (primary production)2.4 kg CO₂/kg
Embodied Water60 L/kg7.2 gal/lb
Typical Recycled Content25%

Manufacturability7

E70C-Ni2 AW-C's machinability is good (57/100, better than 71% of steel grades); weldability excellent (92/100); formability fair (45/100).

MachinabilityGood57/100
Machinability Rating (AISI 1212 = 100 %)62%
WeldabilityExcellent92/100
Formability (cold)Fair45/100
Brazeability / SolderabilityGood55/100
PolishabilityFair45/100
Anodizing Responsen/a — ferrous consumable; use paint, metallizing or galvanizing for protection

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with E70C-Ni2 AW-C

Is E70C-Ni2 easy to machine?

Weld deposit machines/grinds like normalized low-alloy steel (~60 % of AISI 1212); use carbide tooling and expect variable hardness across bead and HAZ.

Can E70C-Ni2 be welded?

Run DCEP with 75–80 % Ar/CO₂ (M) or CO₂ (C), keep interpass ≤150–250 °C and heat input moderate to protect low-temperature toughness; keep wire dry to avoid hydrogen cracking.

Can E70C-Ni2 be formed, bent or molded?

Not a wrought product — supplied as drawn seamed/seamless cored wire on spools; no forming operations on the deposit beyond weld-cap dressing.

What surface finishes work on E70C-Ni2?

Bare ferrous deposit rusts quickly; blast, prime and paint or metallize the weldment, and dress caps for fatigue-critical joints.

E70C-Ni2 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
Cweld metal analysis per AWS A5.29≤ 0.120.06
Mn≤ 1.51.1
Si≤ 0.80.45
Nisource of low-temperature toughness1.75 – 2.752.2
Cr≤ 0.150.03
Mo≤ 0.350.02
V≤ 0.050.01
Cuincludes any copper coating≤ 0.350.05
P≤ 0.030.01
S≤ 0.030.01
Febalance—

E70C-Ni2 AW-C — frequently asked

What is E70C-Ni2 AW-C used for?

E70C-Ni2 AW-C is typically used for low-temperature storage tanks, offshore structural steel, arctic pipeline construction and LNG-adjacent structural steel. In short: 2 % Ni toughness filler; good low-temperature notch toughness; cored wire for C-Mn steels.

What is the yield strength of E70C-Ni2 AW-C?

E70C-Ni2 AW-C has a typical yield strength of 460 MPa (66.7 ksi) and a tensile strength of 550 MPa (79.8 ksi) — stronger than 55% of steel grades. Strength varies by condition: see the 4 listed tempers.

Is E70C-Ni2 AW-C easy to machine?

Reasonably — machinability is rated good (57/100, better than 71% of steel grades). Weld deposit machines/grinds like normalized low-alloy steel (~60 % of AISI 1212); use carbide tooling and expect variable hardness across bead and HAZ.

Can E70C-Ni2 AW-C be welded?

Yes — weldability is rated excellent (92/100). Run DCEP with 75–80 % Ar/CO₂ (M) or CO₂ (C), keep interpass ≤150–250 °C and heat input moderate to protect low-temperature toughness; keep wire dry to avoid hydrogen cracking.

What surface finishes work on E70C-Ni2 AW-C?

Bare ferrous deposit rusts quickly; blast, prime and paint or metallize the weldment, and dress caps for fatigue-critical joints.

Can E70C-Ni2 AW-C be formed, bent or molded?

Not a wrought product — supplied as drawn seamed/seamless cored wire on spools; no forming operations on the deposit beyond weld-cap dressing.

What is the maximum service temperature of E70C-Ni2 AW-C?

E70C-Ni2 AW-C is rated for continuous use to about 400°C (752 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between E70C-Ni2-AW and E70C-Ni2 PWHT?

AW is the default condition — default condition: properties of the deposit straight off the arc, no post-weld heat treatment. PWHT: pick when the fabrication code requires stress relief: strength drops slightly, ductility and dimensional stability improve. Yield strength is 470 MPa in AW versus 430 MPa in PWHT.

Sources

  1. AWS A5.29/A5.29M — Low-Alloy Steel Electrodes for Flux Cored Arc Welding — American Welding Society (2010)
  2. ASM Handbook Vol. 6 — Welding, Brazing and Soldering — ASM International (1993)
  3. ASM Handbook Vol. 1 — Properties and Selection: Irons, Steels — ASM International (1990)
  4. Metal-cored / flux-cored 2 %Ni wire consumable datasheets — Lincoln Electric / ESAB / Kobelco (2023)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.