FabDigitFabDigit

Copper Alloy C14300-H02

Supply condition

UNS C14300 · ASTM B105

H02 = half hard

Balanced strength and bend formability for stamped current-carrying parts and terminals.

High cost $$$$

Values for the H02 condition

Other C14300 tempers and conditions

C14300 is listed in 5 conditions; see the grade overview at C14300.

Compare all 5 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
Annealed to 0.025 mm grain size
Pick for maximum formability, deep drawing or when highest conductivity is needed before final forming.762354545 HB93 % IACS
H02This page
Half hard
Balanced strength and bend formability for stamped current-carrying parts and terminals.2402901472 HB92 % IACS
H04Default
Full hard
Default stock condition — hard-drawn trolley/contact wire, commutator segments and wear-resistant conductors.305345890 HB90 % IACS
Spring hard
Choose where spring force and high hardness must coexist with near-copper conductivity.3503804100 HB89 % IACS
Extra spring hard
Maximum strength/hardness condition for thin springs, contact fingers and fine hard wire; almost no remaining formability.3704003106 HB88 % IACS

What is C14300-H02?

C14300-H02 is C14300 supplied in the H02 condition — balanced strength and bend formability for stamped current-carrying parts and terminals. C14300-H02 has a yield strength of 240 MPa (34.8 ksi) and a tensile strength of 290 MPa (42.1 ksi) — stronger than 52% of copper alloy grades. Elongation at break is 14% and the elastic modulus is 117 GPa (17 Msi). C14300-H02 has a density of 8.89 g/cm³ (0.321 lb/in³), heavier than 72% of copper alloy grades. It melts at 1,076°C (1,969 °F). H04 is the default condition FabDigit quotes; H02 is available on request or by drawing note.

Advantages

  • Conducts heat well — 355 W/m·K (205.1 BTU/hr·ft·°F), better than 90% of copper alloy grades
  • High electrical conductivity — 92 % IACS, better than 89% of copper alloy grades

Limitations

  • Difficult to machine — 25/100, worse than 86% of copper alloy grades

C14300-H02 properties

Typical room-temperature values for C14300-H02; 16 are specific to this condition. Other listed values are C14300 reference data and may not represent this condition. Bars are the position among copper alloy grades.

Physical3

C14300-H02 has a density of 8.89 g/cm³ (0.321 lb/in³), heavier than 72% of copper alloy grades. It melts at 1,076°C (1,969 °F).

Density8.89 g/cm³0.32 lb/in³
Melting Point (Solidus)1,076°C1,969 °F
Liquidus Temperature1,083°C1,981 °F

Mechanical12

C14300-H02 has a yield strength of 240 MPa (34.8 ksi) and a tensile strength of 290 MPa (42.1 ksi) — stronger than 52% of copper alloy grades. Elongation at break is 14% and the elastic modulus is 117 GPa (17 Msi).

Elastic (Young's) Modulus117 GPa17 Msi
Shear Modulus44 GPa6.4 Msi
Bulk Modulus140 GPa20.3 Msi
Poisson's Ratio0.34
Tensile Strength (Ultimate)290 MPa42.1 ksi
Yield Strength (0.2% offset)240 MPa34.8 ksi
Elongation at Break14%
Shear Strength185 MPa26.8 ksi
Fatigue Strength (Endurance Limit)110 MPa16 ksi
Hardness, Brinell72 HB
Hardness, Rockwell B35 HRB
Hardness, Vickers78 HV

Thermal6

C14300-H02 is rated for continuous service to 220°C (428 °F). It conducts heat at 355 W/m·K (205.1 BTU/hr·ft·°F), better than 90% of copper alloy grades. Thermal expansion is 17 µm/m·K (9.44 µin/in·°F).

Thermal Conductivity355 W/m·K205 BTU/hr·ft·°F
Specific Heat Capacity385 J/kg·K0.09 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)17 µm/m·K9.4 µin/in·°F
Latent Heat of Fusion205 J/g88.1 BTU/lb
Max Service Temperature (continuous)220°C428 °F
Min Service Temperature-200°C-328 °F

Electrical3

C14300-H02 conducts electricity at 92 % IACS, better than 89% of copper alloy grades.

Electrical Conductivity92 % IACS
Electrical Resistivity1.87×10⁻⁸ Ω·m0.736 µΩ·in
Magnetic Responsenon-magnetic

Chemical & Environmental3

Corrosion resistance is good (65/100), better than 58% of copper alloy grades.

Galvanic Potential (seawater, vs SCE)-0.2 V
Corrosion ResistanceGood65/100
Chemical Resistance SummaryGood in fresh/marine atmospheres, potable water and non-oxidising acids; attacked by ammonia/amines, oxidising acids, sulphides and mercury salts; forms protective patina outdoors.

Sustainability4

Producing a kilogram of C14300-H02 takes about 57 MJ of energy and emits 3.6 kg of CO₂ — less than 52% of copper alloy grades. Typical recycled content is 30%.

Embodied Energy (primary production)57 MJ/kg24,506 BTU/lb
Embodied Carbon (primary production)3.6 kg CO₂/kg
Embodied Water250 L/kg30 gal/lb
Typical Recycled Content30%

Manufacturability8

C14300-H02's machinability is poor (25/100, worse than 86% of copper alloy grades); weldability fair (35/100); formability good (60/100).

MachinabilityPoor25/100
Machinability Rating (AISI 1212 = 100 %)20%
WeldabilityFair35/100
Formability (cold)Good60/100
CastabilityFair45/100
Brazeability / SolderabilityVery good80/100
PolishabilityVery good75/100
Anodizing Responsen/a — copper alloys are not anodized; use tin, silver or nickel plating instead

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with C14300-H02

Is C14300 easy to machine?

Machines like tough pitch copper — gummy, needs sharp positive-rake tools, high speed and flood coolant; local exhaust advised because cadmium-bearing fines/fumes are toxic.

Can C14300 be welded?

Resistance and brazing/soldering are excellent; fusion welding is difficult (high conductivity) and generates hazardous cadmium oxide fume, so forced ventilation is mandatory.

Can C14300 be formed, bent or molded?

Anneal to OS025 for deep drawing or heavy bending; H04–H10 tempers should only be gently formed and can be stress-relieved near 200 °C without much strength loss.

What surface finishes work on C14300?

Not anodizable; tin, silver or nickel plate for solderability and contact stability, or leave bright and expect a natural patina.

C14300 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
Cdcadmium addition for strength and softening resistance0.05 – 0.150.1
CuCu + Ag + Cd ≥ 99.9 % per CDA registration; oxygen-free or deoxidized base≥ 99.9 (balance)—

C14300-H02 — frequently asked

What is C14300-H02 used for?

C14300-H02 is typically used for trolley and contact wire, electrical connectors and commutator segments. In short: wear-resistant conductor copper; 90% IACS with 305 MPa yield; legacy contact-wire grade.

What is the yield strength of C14300-H02?

C14300-H02 has a typical yield strength of 240 MPa (34.8 ksi) and a tensile strength of 290 MPa (42.1 ksi) — stronger than 52% of copper alloy grades. Strength varies by condition: see the 5 listed tempers.

Is C14300-H02 easy to machine?

Not especially — machinability is rated poor (25/100, worse than 86% of copper alloy grades). Machines like tough pitch copper — gummy, needs sharp positive-rake tools, high speed and flood coolant; local exhaust advised because cadmium-bearing fines/fumes are toxic.

Can C14300-H02 be welded?

With care — weldability is rated fair (35/100). Resistance and brazing/soldering are excellent; fusion welding is difficult (high conductivity) and generates hazardous cadmium oxide fume, so forced ventilation is mandatory.

What surface finishes work on C14300-H02?

Not anodizable; tin, silver or nickel plate for solderability and contact stability, or leave bright and expect a natural patina.

Can C14300-H02 be formed, bent or molded?

Anneal to OS025 for deep drawing or heavy bending; H04–H10 tempers should only be gently formed and can be stress-relieved near 200 °C without much strength loss.

What is the maximum service temperature of C14300-H02?

C14300-H02 is rated for continuous use to about 220°C (428 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between C14300-H04 and C14300-OS025?

H04 is the default condition — default stock condition — hard-drawn trolley/contact wire, commutator segments and wear-resistant conductors. OS025: pick for maximum formability, deep drawing or when highest conductivity is needed before final forming. Yield strength is 305 MPa in H04 versus 76 MPa in OS025.

Sources

  1. ASTM B105 — Hard-Drawn Copper Alloy Wires for Electric Conductors — ASTM International (2018)
  2. CDA Standard Designation C14300 alloy datasheet — Copper Development Association (copper.org) (2023)
  3. ASM Handbook Vol.2 — Properties and Selection: Nonferrous Alloys and Special-Purpose Materials — ASM International (1990)
  4. ASTM B601 — Temper Designations for Copper and Copper Alloys — ASTM International (2019)
  5. ASM Handbook Vol.13 — Corrosion — ASM International (2005)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.