Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
F + stress relieved
Optional low-temperature anneal to stabilise dimensions of thin-walled or heavily machined castings.1403002272 HB11.5 % IACS
F-SANDDefault
F
Standard supply condition for valve bodies, pump housings and general pressure-tight castings.1503102075 HB11 % IACS
F
For large sleeves, worm-gear rims and rings where a dense, inclusion-swept wall is required.1603201878 HB11 % IACS
F-PMThis page
F
Chill-cast finer structure for smaller repeat parts needing better surface and slightly higher strength.1653401680 HB11 % IACS
F
Choose for machined bushings, wear rings and bar stock: dense, low-porosity, highest yield strength.1953301285 HB11 % IACS

What is BC2 F-PM?

BC2 F-PM is BC2 supplied in the F-PM condition — chill-cast finer structure for smaller repeat parts needing better surface and slightly higher strength. BC2 F-PM has a yield strength of 165 MPa (23.9 ksi) and a tensile strength of 340 MPa (49.3 ksi) — weaker than 64% of copper alloy grades. Elongation at break is 16% and the elastic modulus is 105 GPa (15.2 Msi). BC2 F-PM has a density of 8.8 g/cm³ (0.318 lb/in³), heavier than 58% of copper alloy grades. It melts at 854°C (1,569 °F). F-SAND is the default condition FabDigit quotes; F-PM is available on request or by drawing note.

Limitations

  • Limited formability — 10/100, worse than 89% of copper alloy grades
  • Difficult to weld — 25/100, worse than 78% of copper alloy grades

BC2 F-PM properties

Typical room-temperature values for BC2 F-PM; 21 are specific to this condition. Other listed values are BC2 reference data and may not represent this condition. Bars are the position among copper alloy grades.

Physical3

BC2 F-PM has a density of 8.8 g/cm³ (0.318 lb/in³), heavier than 58% of copper alloy grades. It melts at 854°C (1,569 °F).

Density8.8 g/cm³0.32 lb/in³
Melting Point (Solidus)854°C1,569 °F
Liquidus Temperature1,000°C1,832 °F

Mechanical15

BC2 F-PM has a yield strength of 165 MPa (23.9 ksi) and a tensile strength of 340 MPa (49.3 ksi) — weaker than 64% of copper alloy grades. Elongation at break is 16% and the elastic modulus is 105 GPa (15.2 Msi).

Elastic (Young's) Modulus105 GPa15.2 Msi
Shear Modulus39 GPa5.7 Msi
Bulk Modulus108 GPa15.7 Msi
Poisson's Ratio0.34
Tensile Strength (Ultimate)340 MPa49.3 ksi
Yield Strength (0.2% offset)165 MPa23.9 ksi
Elongation at Break16%
Reduction in Area16%
Compressive Strength320 MPa46.4 ksi
Shear Strength230 MPa33.4 ksi
Fatigue Strength (Endurance Limit)115 MPa16.7 ksi
Charpy V-Notch Impact (RT)12 J8.9 ft·lbf
Hardness, Brinell80 HB
Hardness, Rockwell B40 HRB
Hardness, Vickers84 HV

Thermal6

BC2 F-PM is rated for continuous service to 250°C (482 °F). It conducts heat at 72 W/m·K (41.6 BTU/hr·ft·°F), worse than 52% of copper alloy grades. Thermal expansion is 18 µm/m·K (10 µin/in·°F).

Thermal Conductivity72 W/m·K41.6 BTU/hr·ft·°F
Specific Heat Capacity377 J/kg·K0.09 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)18 µm/m·K10 µin/in·°F
Latent Heat of Fusion190 J/g81.7 BTU/lb
Max Service Temperature (continuous)250°C482 °F
Min Service Temperature-196°C-321 °F

Electrical3

BC2 F-PM conducts electricity at 11 % IACS, worse than 68% of copper alloy grades.

Electrical Conductivity11 % IACS
Electrical Resistivity1.57×10⁻⁷ Ω·m6.18 µΩ·in
Magnetic Responsenon-magnetic

Chemical & Environmental3

Corrosion resistance is very good (70/100), better than 76% of copper alloy grades.

Galvanic Potential (seawater, vs SCE)-0.26 V
Corrosion ResistanceVery good70/100
Chemical Resistance SummaryGood in fresh and salt water, neutral steam and condensate, mineral oils and most non-oxidizing acids; attacked by ammonia/amines, oxidizing acids (HNO3), and high-velocity chlorinated or sulfide-bearing waters (erosion-corrosion, dezincification of the Zn-rich phase).

Sustainability4

Producing a kilogram of BC2 F-PM takes about 55 MJ of energy and emits 3.4 kg of CO₂ — less than 72% of copper alloy grades. Typical recycled content is 45%.

Embodied Energy (primary production)55 MJ/kg23,646 BTU/lb
Embodied Carbon (primary production)3.4 kg CO₂/kg
Embodied Water260 L/kg31.2 gal/lb
Typical Recycled Content45%

Manufacturability8

BC2 F-PM's machinability is fair (45/100, better than 64% of copper alloy grades); weldability poor (25/100); formability not recommended (10/100).

MachinabilityFair45/100
Machinability Rating (AISI 1212 = 100 %)30%
WeldabilityPoor25/100
Formability (cold)Not recommended10/100
CastabilityVery good80/100
Brazeability / SolderabilityExcellent85/100
PolishabilityVery good70/100
Anodizing Responsen/a — copper alloy; use chemical patination, tin/nickel plating or clear lacquer instead

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with BC2 F-PM

Is BC2 easy to machine?

Machines to a short chip at roughly 30% of free-cutting brass; use sharp positive-rake carbide, moderate feeds and generous coolant, and expect slight smearing from the soft alpha matrix.

Can BC2 be welded?

Fusion welding is poor (hot-short, tin oxide films); repair by braze welding or GTAW with matching Cu-Sn filler and preheat 150–250 °C, otherwise prefer brazing/soldering.

Can BC2 be formed, bent or molded?

Casting alloy only — excellent for pressure-tight sand, chill, centrifugal and continuous casting; provide directional solidification and adequate feeding to avoid tin inverse segregation and microporosity.

What surface finishes work on BC2?

Not anodizable; take a good mechanical polish and accepts tin, nickel or chrome plating, chemical brown/black patination, or clear lacquer for architectural parts.

BC2 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
Sn7 – 98
Zn3 – 54
Pbimpurity limit≤ 10.3
Niimpurity limit≤ 1—
Feimpurity limit≤ 0.2—
Sbimpurity limit≤ 0.2—
Pimpurity limit≤ 0.05—
Alimpurity limit≤ 0.01—
Siimpurity limit≤ 0.01—
Mnimpurity limit≤ 0.2—
Simpurity limit≤ 0.05—
Cu≥ 86 (balance)—

BC2 F-PM — frequently asked

What is BC2 F-PM used for?

BC2 F-PM is typically used for pipe fittings, pump housings and small gears. In short: lead-free gun metal; pressure-tight general bronze; higher ductility than PBC2.

What is the yield strength of BC2 F-PM?

BC2 F-PM has a typical yield strength of 165 MPa (23.9 ksi) and a tensile strength of 340 MPa (49.3 ksi) — weaker than 64% of copper alloy grades. Strength varies by condition: see the 5 listed tempers.

Is BC2 F-PM easy to machine?

Reasonably — machinability is rated fair (45/100, better than 64% of copper alloy grades). Machines to a short chip at roughly 30% of free-cutting brass; use sharp positive-rake carbide, moderate feeds and generous coolant, and expect slight smearing from the soft alpha matrix.

Can BC2 F-PM be welded?

Not readily — weldability is rated poor (25/100). Fusion welding is poor (hot-short, tin oxide films); repair by braze welding or GTAW with matching Cu-Sn filler and preheat 150–250 °C, otherwise prefer brazing/soldering.

What surface finishes work on BC2 F-PM?

Not anodizable; take a good mechanical polish and accepts tin, nickel or chrome plating, chemical brown/black patination, or clear lacquer for architectural parts.

Can BC2 F-PM be formed, bent or molded?

Casting alloy only — excellent for pressure-tight sand, chill, centrifugal and continuous casting; provide directional solidification and adequate feeding to avoid tin inverse segregation and microporosity.

What is the maximum service temperature of BC2 F-PM?

BC2 F-PM is rated for continuous use to about 250°C (482 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between BC2 F-SAND and BC2 F-CC?

F-SAND is the default condition — standard supply condition for valve bodies, pump housings and general pressure-tight castings. F-CC: choose for machined bushings, wear rings and bar stock: dense, low-porosity, highest yield strength. Yield strength is 150 MPa in F-SAND versus 195 MPa in F-CC.

Sources

  1. JIS H5120 Copper alloy castings (CAC402 / former BC2) — JSA (2016)
  2. ASTM B584 Standard Specification for Copper Alloy Sand Castings for General Applications (C90300/C90500) — ASTM (2014)
  3. Copper Alloy Datasheets C90300 / C90500 — Copper Development Association (copper.org) (2023)
  4. ASM Handbook Vol.2 — Properties and Selection: Nonferrous Alloys — ASM International (1990)
  5. ASM Handbook Vol.15 — Casting — ASM International (2008)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.