FabDigitFabDigit

Nickel Alloy N-12M-1-F (As fabricated)

Temper

UNS N30012 · ASTM A494 N-12M-1

Only for non-critical or mild-service parts: interdendritic Mo-rich carbides remain, lowering ductility and intergranular corrosion resistance.

High cost $$$$

Values for the F condition

Other N-12M-1 tempers and conditions

N-12M-1 is listed in 3 conditions; see the grade overview at N-12M-1.

Compare all 3 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
Weld repaired then re-solution annealed
Required route when castings are weld-repaired for acid service, since re-annealing removes HAZ carbides and knife-line attack susceptibility.365565815 HRC1.3 % IACS
SADefault
Solution annealed and quenched
Standard supply condition: solution anneal ~1095–1150 °C with rapid quench to dissolve Mo-rich carbides and maximize HCl corrosion resistance.3705851014 HRC1.3 % IACS
FThis page
As fabricated
Only for non-critical or mild-service parts: interdendritic Mo-rich carbides remain, lowering ductility and intergranular corrosion resistance.3805406215 HB1.2 % IACS

What is N-12M-1-F?

N-12M-1-F is N-12M-1 in the F temper — only for non-critical or mild-service parts: interdendritic Mo-rich carbides remain, lowering ductility and intergranular corrosion resistance. N-12M-1-F has a yield strength of 380 MPa (55.1 ksi) and a tensile strength of 540 MPa (78.3 ksi) — weaker than 53% of nickel alloy grades. Elongation at break is 6% and the elastic modulus is 215 GPa (31.2 Msi). N-12M-1-F has a density of 9.24 g/cm³ (0.334 lb/in³), heavier than 99% of nickel alloy grades. It melts at 1,320°C (2,408 °F). SA is the default condition FabDigit quotes; F is available on request or by drawing note.

Limitations

  • Low electrical conductivity — 1.2 % IACS, worse than 99% of nickel alloy grades
  • Low fracture toughness — 35 MPa·√m (31.9 ksi·√in), worse than 98% of nickel alloy grades
  • Hard to polish — 55/100, worse than 95% of nickel alloy grades
  • Limited ductility — 6%, worse than 90% of nickel alloy grades
  • Needs corrosion protection — 62/100, worse than 87% of nickel alloy grades

N-12M-1-F properties

Typical room-temperature values for N-12M-1-F; 21 are specific to this condition. Other listed values are N-12M-1 reference data and may not represent this condition. Bars are the position among nickel alloy grades.

Physical3

N-12M-1-F has a density of 9.24 g/cm³ (0.334 lb/in³), heavier than 99% of nickel alloy grades. It melts at 1,320°C (2,408 °F).

Density9.24 g/cm³0.33 lb/in³
Melting Point (Solidus)1,320°C2,408 °F
Liquidus Temperature1,350°C2,462 °F

Mechanical17

N-12M-1-F has a yield strength of 380 MPa (55.1 ksi) and a tensile strength of 540 MPa (78.3 ksi) — weaker than 53% of nickel alloy grades. Elongation at break is 6% and the elastic modulus is 215 GPa (31.2 Msi).

Elastic (Young's) Modulus215 GPa31.2 Msi
Shear Modulus84 GPa12.2 Msi
Bulk Modulus181 GPa26.3 Msi
Poisson's Ratio0.31
Tensile Strength (Ultimate)540 MPa78.3 ksi
Yield Strength (0.2% offset)380 MPa55.1 ksi
Elongation at Break6%
Reduction in Area7%
Compressive Strength400 MPa58 ksi
Shear Strength350 MPa50.8 ksi
Fatigue Strength (Endurance Limit)205 MPa29.7 ksi
Fracture Toughness (K_IC)35 MPa·√m31.9 ksi·√in
Charpy V-Notch Impact (RT)16 J11.8 ft·lbf
Hardness, Brinell215 HB
Hardness, Rockwell B95 HRB
Hardness, Rockwell C14 HRC
Hardness, Vickers225 HV

Thermal6

N-12M-1-F is rated for continuous service to 600°C (1,112 °F). It conducts heat at 10.8 W/m·K (6.24 BTU/hr·ft·°F), worse than 66% of nickel alloy grades. Thermal expansion is 10.3 µm/m·K (5.72 µin/in·°F).

Thermal Conductivity10.8 W/m·K6.2 BTU/hr·ft·°F
Specific Heat Capacity377 J/kg·K0.09 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)10.3 µm/m·K5.7 µin/in·°F
Latent Heat of Fusion285 J/g123 BTU/lb
Max Service Temperature (continuous)600°C1,112 °F
Min Service Temperature-50°C-58 °F

Electrical3

N-12M-1-F conducts electricity at 1.2 % IACS, worse than 99% of nickel alloy grades.

Electrical Conductivity1.2 % IACS
Electrical Resistivity1.4×10⁻⁶ Ω·m55.1 µΩ·in
Magnetic Responsenon-magnetic

Chemical & Environmental3

Corrosion resistance is good (62/100), worse than 87% of nickel alloy grades.

Galvanic Potential (seawater, vs SCE)-0.12 V
Corrosion ResistanceGood62/100
Chemical Resistance SummaryOutstanding in de-aerated hydrochloric acid at all concentrations to ~70 °C, plus HF, H3PO4, H2SO4 and non-oxidizing chlorides; attacked rapidly by oxidizing media (HNO3, wet Cl2, FeCl3/CuCl2 contamination, aerated acids) and cannot resist strong caustic-plus-oxidizer service; HAZ knife-line attack risk in as-welded condition.

Sustainability4

Producing a kilogram of N-12M-1-F takes about 155 MJ of energy and emits 13 kg of CO₂ — less than 58% of nickel alloy grades. Typical recycled content is 40%.

Embodied Energy (primary production)155 MJ/kg66,638 BTU/lb
Embodied Carbon (primary production)13 kg CO₂/kg
Embodied Water300 L/kg35.9 gal/lb
Typical Recycled Content40%

Manufacturability8

N-12M-1-F's machinability is poor (18/100, worse than 61% of nickel alloy grades); weldability poor (25/100); formability not recommended (8/100).

MachinabilityPoor18/100
Machinability Rating (AISI 1212 = 100 %)10%
WeldabilityPoor25/100
Formability (cold)Not recommended8/100
CastabilityGood55/100
Brazeability / SolderabilityFair40/100
PolishabilityGood55/100
Anodizing Responsen/a — nickel alloy, not anodized; pickle/passivate or electropolish instead

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with N-12M-1-F

Is N-12M-1 easy to machine?

Machine like a work-hardening Ni-Mo alloy: rigid setup, positive-rake carbide, low speed (15–25 m/min) with heavy feed, flood coolant, and no dwelling to avoid glazing.

Can N-12M-1 be welded?

Weld with matching Ni-Mo (ENiMo-1/ERNiMo-2 class) filler, low heat input and no preheat; because of the 0.12 % C limit, re-solution anneal after welding for acid service to avoid knife-line/HAZ attack.

Can N-12M-1 be formed, bent or molded?

Sand or investment cast only; use generous risering and controlled pour temperature (~1450–1500 °C) as the alloy is hot-tear and shrinkage sensitive — not a wrought/formable product.

What surface finishes work on N-12M-1?

Grit blast then pickle in HNO3-HF or electropolish to remove oxide; no anodizing — finish by mechanical polish or leave as-machined for acid service.

N-12M-1 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
Mo26 – 3330
Fe4 – 65
Vdistinguishes N-12M-1 from N-12M-20.2 – 0.60.35
Chigher C than N-12M-2 (0.07 max)≤ 0.120.08
Si≤ 10.6
Mn≤ 10.6
Crresidual only; no deliberate Cr≤ 10.5
Co≤ 2.5—
P≤ 0.04—
S≤ 0.03—
Nibalance, ~61-62% nominalbalance—

N-12M-1-F — frequently asked

What is N-12M-1-F used for?

N-12M-1-F is typically used for hydrochloric acid pump castings, chemical reactor valve bodies, impellers for non-oxidizing acid pumps, acid transfer pump casings and covers, cast fittings and elbows for HCl piping and agitator and mixer components in acid vessels. In short: cast alloy for HCl; chromium-free Ni-Mo casting; poor in oxidizing acids.

What is the yield strength of N-12M-1-F?

N-12M-1-F has a typical yield strength of 380 MPa (55.1 ksi) and a tensile strength of 540 MPa (78.3 ksi) — weaker than 53% of nickel alloy grades. Strength varies by condition: see the 3 listed tempers.

Is N-12M-1-F easy to machine?

Not especially — machinability is rated poor (18/100, worse than 61% of nickel alloy grades). Machine like a work-hardening Ni-Mo alloy: rigid setup, positive-rake carbide, low speed (15–25 m/min) with heavy feed, flood coolant, and no dwelling to avoid glazing.

Can N-12M-1-F be welded?

Not readily — weldability is rated poor (25/100). Weld with matching Ni-Mo (ENiMo-1/ERNiMo-2 class) filler, low heat input and no preheat; because of the 0.12 % C limit, re-solution anneal after welding for acid service to avoid knife-line/HAZ attack.

What surface finishes work on N-12M-1-F?

Grit blast then pickle in HNO3-HF or electropolish to remove oxide; no anodizing — finish by mechanical polish or leave as-machined for acid service.

Can N-12M-1-F be formed, bent or molded?

Sand or investment cast only; use generous risering and controlled pour temperature (~1450–1500 °C) as the alloy is hot-tear and shrinkage sensitive — not a wrought/formable product.

What is the maximum service temperature of N-12M-1-F?

N-12M-1-F is rated for continuous use to about 600°C (1,112 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between N-12M-1-SA and N-12M-1-F?

SA is the default condition — standard supply condition: solution anneal ~1095–1150 °C with rapid quench to dissolve Mo-rich carbides and maximize HCl corrosion resistance. F: only for non-critical or mild-service parts: interdendritic Mo-rich carbides remain, lowering ductility and intergranular corrosion resistance. Yield strength is 370 MPa in SA versus 380 MPa in F.

Sources

  1. ASTM A494/A494M — Castings, Nickel and Nickel Alloy — ASTM International (2023)
  2. ASM Specialty Handbook: Nickel, Cobalt, and Their Alloys — ASM International (2000)
  3. ASM Handbook Vol. 2 — Properties of Nonferrous Alloys — ASM International (1990)
  4. Hastelloy B / B-2 alloy technical data (Ni-Mo family) — Haynes International (2020)
  5. UNS N30012 alloy record — SAE/ASTM Unified Numbering System (2020)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.