FabDigitFabDigit

Copper Alloy Cu-ETP1-R360

Supply condition

EN CR003A

R360 = extra hard drawn wire, Rm ≥ 360 MPa

Heavily drawn fine wire for hard-drawn conductors and springy contacts where tensile strength matters more than elongation.

High cost $$$$

Values for the R360 condition

Other Cu-ETP1 tempers and conditions

Cu-ETP1 is listed in 7 conditions; see the grade overview at Cu-ETP1.

Compare all 7 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
As cast
Unwrought cast product to EN 1976 used as remelt / rolling stock rather than as a finished engineering shape.551753040 HB101 % IACS
annealed / soft, Rm ≥ 200 MPa
Fully soft condition for maximum conductivity, bending and winding of magnet wire or flexible busbar.602154243 HB101.5 % IACS
MDefault
Thermomechanically controlled processed
Standard 8 mm bright rod / wire rod as supplied by the rod mill — the feedstock for all drawing operations.702204045 HB101.5 % IACS
Hardness temper, 40–65 HV
Ordered when a hardness window rather than a strength window is specified — essentially soft-drawn rod/bar.802253550 HB101 % IACS
half-hard drawn, Rm ≥ 240 MPa
Half-hard drawn rod/bar giving a workable compromise between strength and remaining bendability for busbar and terminals.1802551575 HB100 % IACS
hard drawn, Rm ≥ 290 MPa
Hard-drawn rod/bar for overhead conductors, commutator bars and mechanically loaded electrical parts.260315695 HB98.5 % IACS
R360This page
Extra hard drawn wire, Rm ≥ 360 MPa
Heavily drawn fine wire for hard-drawn conductors and springy contacts where tensile strength matters more than elongation.3403852110 HB97.5 % IACS

What is Cu-ETP1-R360?

Cu-ETP1-R360 is Cu-ETP1 supplied in the R360 condition — heavily drawn fine wire for hard-drawn conductors and springy contacts where tensile strength matters more than elongation. Cu-ETP1-R360 has a yield strength of 340 MPa (49.3 ksi) and a tensile strength of 385 MPa (55.8 ksi) — stronger than 71% of copper alloy grades. Elongation at break is 2% and the elastic modulus is 120 GPa (17.4 Msi). Cu-ETP1-R360 has a density of 8.93 g/cm³ (0.323 lb/in³), heavier than 82% of copper alloy grades. It melts at 1,065°C (1,949 °F). M is the default condition FabDigit quotes; R360 is available on request or by drawing note.

Advantages

  • High electrical conductivity — 97.5 % IACS, better than 93% of copper alloy grades
  • Conducts heat well — 380 W/m·K (219.6 BTU/hr·ft·°F), better than 91% of copper alloy grades

Limitations

  • Limited service temperature — 120°C (248 °F), worse than 100% of copper alloy grades
  • Limited ductility — 2%, worse than 98% of copper alloy grades

Cu-ETP1-R360 properties

Typical room-temperature values for Cu-ETP1-R360; 20 are specific to this condition. Other listed values are Cu-ETP1 reference data and may not represent this condition. Bars are the position among copper alloy grades.

Physical3

Cu-ETP1-R360 has a density of 8.93 g/cm³ (0.323 lb/in³), heavier than 82% of copper alloy grades. It melts at 1,065°C (1,949 °F).

Density8.93 g/cm³0.32 lb/in³
Melting Point (Solidus)1,065°C1,949 °F
Liquidus Temperature1,083°C1,981 °F

Mechanical13

Cu-ETP1-R360 has a yield strength of 340 MPa (49.3 ksi) and a tensile strength of 385 MPa (55.8 ksi) — stronger than 71% of copper alloy grades. Elongation at break is 2% and the elastic modulus is 120 GPa (17.4 Msi).

Elastic (Young's) Modulus120 GPa17.4 Msi
Shear Modulus44 GPa6.4 Msi
Bulk Modulus140 GPa20.3 Msi
Poisson's Ratio0.34
Tensile Strength (Ultimate)385 MPa55.8 ksi
Yield Strength (0.2% offset)340 MPa49.3 ksi
Elongation at Break2%
Reduction in Area55%
Shear Strength230 MPa33.4 ksi
Fatigue Strength (Endurance Limit)115 MPa16.7 ksi
Charpy V-Notch Impact (RT)28 J20.7 ft·lbf
Hardness, Brinell110 HB
Hardness, Vickers115 HV

Thermal6

Cu-ETP1-R360 is rated for continuous service to 120°C (248 °F). It conducts heat at 380 W/m·K (219.6 BTU/hr·ft·°F), better than 91% of copper alloy grades. Thermal expansion is 17 µm/m·K (9.44 µin/in·°F).

Thermal Conductivity380 W/m·K220 BTU/hr·ft·°F
Specific Heat Capacity385 J/kg·K0.09 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)17 µm/m·K9.4 µin/in·°F
Latent Heat of Fusion205 J/g88.1 BTU/lb
Max Service Temperature (continuous)120°C248 °F
Min Service Temperature-250°C-418 °F

Electrical3

Cu-ETP1-R360 conducts electricity at 97.5 % IACS, better than 93% of copper alloy grades.

Electrical Conductivity97.5 % IACS
Electrical Resistivity1.77×10⁻⁸ Ω·m0.697 µΩ·in
Magnetic Responsenon-magnetic

Chemical & Environmental3

Corrosion resistance is good (65/100), better than 58% of copper alloy grades.

Galvanic Potential (seawater, vs SCE)-0.25 V
Corrosion ResistanceGood65/100
Chemical Resistance SummaryGood in fresh/sea water, non-oxidising acids and most organics; attacked by ammonia and amines (stress-corrosion), nitric acid, oxidising acids, sulphur compounds and mercury salts; forms protective patina outdoors.

Sustainability4

Producing a kilogram of Cu-ETP1-R360 takes about 53 MJ of energy and emits 3.6 kg of CO₂ — less than 85% of copper alloy grades. Typical recycled content is 10%.

Embodied Energy (primary production)53 MJ/kg22,786 BTU/lb
Embodied Carbon (primary production)3.6 kg CO₂/kg
Embodied Water350 L/kg41.9 gal/lb
Typical Recycled Content10%

Manufacturability8

Cu-ETP1-R360's machinability is fair (45/100, better than 64% of copper alloy grades); weldability fair (35/100); formability poor (25/100).

MachinabilityFair45/100
Machinability Rating (AISI 1212 = 100 %)25%
WeldabilityFair35/100
Formability (cold)Poor25/100
CastabilityFair45/100
Brazeability / SolderabilityExcellent85/100
PolishabilityVery good80/100
Anodizing Responsen/a — copper is not anodised; use tin/nickel/silver plating or benzotriazole/lacquer tarnish protection

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with Cu-ETP1-R360

Is Cu-ETP1 easy to machine?

Gummy and long-chipping — use sharp positive-rake tools, high speed, low feed and generous coolant; expect ~20 % of AISI 1212 productivity, consider C14500/C36000 if machining dominates.

Can Cu-ETP1 be welded?

Weldable by GTAW/GMAW with phosphorus-deoxidised filler and high preheat, but oxygen-bearing tough-pitch copper is prone to porosity and hydrogen embrittlement — avoid reducing atmospheres above ~400 °C; prefer Cu-DHP/Cu-OF for welded assemblies.

Can Cu-ETP1 be formed, bent or molded?

Outstanding cold drawing, upsetting and bending in the soft/M condition; interstage anneals at 400–600 °C restore ductility, and hard tempers should be bent generously to avoid edge cracking.

What surface finishes work on Cu-ETP1?

Not anodisable; solders and electroplates (Sn, Ni, Ag) readily, takes a high polish but tarnishes — protect with benzotriazole, lacquer or plating.

Cu-ETP1 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
Otough-pitch oxygen content0.01 – 0.040.03
Agcounted as Cu≤ 0—
Bitighter than Cu-ETP≤ 5×10⁻⁴—
Pb≤ 5×10⁻⁴—
Se≤ 2×10⁻⁴—
Te≤ 2×10⁻⁴—
S≤ 0—
As≤ 5×10⁻⁴—
Sb≤ 4×10⁻⁴—
Fe≤ 0—
Ni≤ 0—
Sn≤ 5×10⁻⁴—
Zn≤ 0—
P≤ 5×10⁻⁴—
total impurities (excl. O, Ag)Cu-CATH-1 quality feed per EN 1978≤ 0.01—
CuCu including Ag, minimum; balance≥ 99.95 (balance)—

Cu-ETP1-R360 — frequently asked

What is Cu-ETP1-R360 used for?

Cu-ETP1-R360 is typically used for electrical rod stock, busbars and high-conductivity connectors. In short: highest-conductivity ETP rod; 101.5 % IACS; poor choice for welding.

What is the yield strength of Cu-ETP1-R360?

Cu-ETP1-R360 has a typical yield strength of 340 MPa (49.3 ksi) and a tensile strength of 385 MPa (55.8 ksi) — stronger than 71% of copper alloy grades. Strength varies by condition: see the 7 listed tempers.

Is Cu-ETP1-R360 easy to machine?

Reasonably — machinability is rated fair (45/100, better than 64% of copper alloy grades). Gummy and long-chipping — use sharp positive-rake tools, high speed, low feed and generous coolant; expect ~20 % of AISI 1212 productivity, consider C14500/C36000 if machining dominates.

Can Cu-ETP1-R360 be welded?

With care — weldability is rated fair (35/100). Weldable by GTAW/GMAW with phosphorus-deoxidised filler and high preheat, but oxygen-bearing tough-pitch copper is prone to porosity and hydrogen embrittlement — avoid reducing atmospheres above ~400 °C; prefer Cu-DHP/Cu-OF for welded assemblies.

What surface finishes work on Cu-ETP1-R360?

Not anodisable; solders and electroplates (Sn, Ni, Ag) readily, takes a high polish but tarnishes — protect with benzotriazole, lacquer or plating.

Can Cu-ETP1-R360 be formed, bent or molded?

Outstanding cold drawing, upsetting and bending in the soft/M condition; interstage anneals at 400–600 °C restore ductility, and hard tempers should be bent generously to avoid edge cracking.

What is the maximum service temperature of Cu-ETP1-R360?

Cu-ETP1-R360 is rated for continuous use to about 120°C (248 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between Cu-ETP1-M and Cu-ETP1-R360?

M is the default condition — standard 8 mm bright rod / wire rod as supplied by the rod mill — the feedstock for all drawing operations. R360: heavily drawn fine wire for hard-drawn conductors and springy contacts where tensile strength matters more than elongation. Yield strength is 70 MPa in M versus 340 MPa in R360.

Sources

  1. EN 1976 — Copper and copper alloys: cast unwrought copper products (Cu-ETP1, CR003A) — CEN (2012)
  2. EN 13601 — Copper rod, bar and wire for general electrical purposes — CEN (2021)
  3. EN 13602 — Drawn round copper wire for electrical conductors — CEN (2013)
  4. EN 1978 — Copper cathodes (Cu-CATH-1) — CEN (1998)
  5. ASM Handbook Vol. 2 — Properties of Copper and Copper Alloys — ASM International (1990)
  6. CDA alloy datasheet C11000 (ETP copper) — Copper Development Association (2023)
  7. IEC 60028 — International standard of resistance for copper — IEC (1925)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.