FabDigitFabDigit

Copper Alloy Cu-DXP-R290

Supply condition

EN CR025A

R290 = hard drawn, Rm ≥ 290 MPa

Pick for rigid straight tube and pressure lines where stiffness and hoop strength matter more than bendability.

High cost $$$$

Values for the R290 condition

Other Cu-DXP tempers and conditions

Cu-DXP is listed in 9 conditions; see the grade overview at Cu-DXP.

Compare all 9 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
As cast
Pick for remelt or as extrusion/rolling feedstock, the form in which Cu-DXP is actually traded under EN 1976/EN 1978.601803042 HB70 % IACS
R220Default
Annealed (soft), Rm ≥ 220 MPa
Default for tube, fittings and deep-drawn parts: maximum ductility, easiest bending and expansion.702304545 HB70 % IACS
Hardness temper, 40–65 HV
Pick when the order is placed to a hardness band instead of a tensile band, e.g. sheet/strip for deep drawing.702304248 HB70 % IACS
Thermomechanically controlled processed
Pick for hot-extruded or hot-rolled semis where dimensions matter and mechanical properties are not guaranteed.802104048 HB70 % IACS
Half-hard, Rm ≥ 250 MPa
Pick for straight tube and fittings needing higher pressure rating while still allowing moderate bending.2002702570 HB69 % IACS
Hardness temper, 55–100 HV
Pick for strip/tube ordered by hardness in the half-hard range for stamping and moderate forming.2002652270 HB69 % IACS
R290This page
Hard drawn, Rm ≥ 290 MPa
Pick for rigid straight tube and pressure lines where stiffness and hoop strength matter more than bendability.260315895 HB68 % IACS
Hardness temper, 90–110 HV
Pick for hard-drawn tube/strip specified by hardness where wall stiffness and dent resistance are key.280320795 HB68 % IACS
Extra hard drawn rod/wire, Rm ≥ 360 MPa
Pick for heavily drawn rod, wire or high-strength small-bore tube where maximum cold-worked strength is needed.3203704110 HB67 % IACS

What is Cu-DXP-R290?

Cu-DXP-R290 is Cu-DXP supplied in the R290 condition — pick for rigid straight tube and pressure lines where stiffness and hoop strength matter more than bendability. Cu-DXP-R290 has a yield strength of 260 MPa (37.7 ksi) and a tensile strength of 315 MPa (45.7 ksi) — stronger than 55% of copper alloy grades. Elongation at break is 8% and the elastic modulus is 117 GPa (17 Msi). Cu-DXP-R290 has a density of 8.94 g/cm³ (0.323 lb/in³), heavier than 90% of copper alloy grades. It melts at 1,083°C (1,981 °F). R220 is the default condition FabDigit quotes; R290 is available on request or by drawing note.

Advantages

  • Readily welded — 88/100, better than 97% of copper alloy grades
  • Conducts heat well — 290 W/m·K (167.6 BTU/hr·ft·°F), better than 83% of copper alloy grades
  • High electrical conductivity — 68 % IACS, better than 82% of copper alloy grades

Limitations

  • Limited service temperature — 120°C (248 °F), worse than 100% of copper alloy grades
  • Difficult to machine — 25/100, worse than 86% of copper alloy grades
  • Limited ductility — 8%, worse than 83% of copper alloy grades

Cu-DXP-R290 properties

Typical room-temperature values for Cu-DXP-R290; 13 are specific to this condition. Other listed values are Cu-DXP reference data and may not represent this condition. Bars are the position among copper alloy grades.

Physical3

Cu-DXP-R290 has a density of 8.94 g/cm³ (0.323 lb/in³), heavier than 90% of copper alloy grades. It melts at 1,083°C (1,981 °F).

Density8.94 g/cm³0.32 lb/in³
Melting Point (Solidus)1,083°C1,981 °F
Liquidus Temperature1,083°C1,981 °F

Mechanical12

Cu-DXP-R290 has a yield strength of 260 MPa (37.7 ksi) and a tensile strength of 315 MPa (45.7 ksi) — stronger than 55% of copper alloy grades. Elongation at break is 8% and the elastic modulus is 117 GPa (17 Msi).

Elastic (Young's) Modulus117 GPa17 Msi
Shear Modulus44 GPa6.4 Msi
Bulk Modulus140 GPa20.3 Msi
Poisson's Ratio0.34
Tensile Strength (Ultimate)315 MPa45.7 ksi
Yield Strength (0.2% offset)260 MPa37.7 ksi
Elongation at Break8%
Reduction in Area55%
Shear Strength200 MPa29 ksi
Fatigue Strength (Endurance Limit)105 MPa15.2 ksi
Hardness, Brinell95 HB
Hardness, Vickers100 HV

Thermal6

Cu-DXP-R290 is rated for continuous service to 120°C (248 °F). It conducts heat at 290 W/m·K (167.6 BTU/hr·ft·°F), better than 83% of copper alloy grades. Thermal expansion is 17.7 µm/m·K (9.83 µin/in·°F).

Thermal Conductivity290 W/m·K168 BTU/hr·ft·°F
Specific Heat Capacity385 J/kg·K0.09 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)17.7 µm/m·K9.8 µin/in·°F
Latent Heat of Fusion205 J/g88.1 BTU/lb
Max Service Temperature (continuous)120°C248 °F
Min Service Temperature-200°C-328 °F

Electrical3

Cu-DXP-R290 conducts electricity at 68 % IACS, better than 82% of copper alloy grades.

Electrical Conductivity68 % IACS
Electrical Resistivity2.46×10⁻⁸ Ω·m0.969 µΩ·in
Magnetic Responsenon-magnetic

Chemical & Environmental3

Corrosion resistance is good (62/100), worse than 57% of copper alloy grades.

Galvanic Potential (seawater, vs SCE)-0.25 V
Corrosion ResistanceGood62/100
Chemical Resistance SummaryVery good in fresh and potable water, steam, most neutral salts, non-oxidizing acids and refrigerants; attacked by ammonia/amines (stress corrosion), oxidizing acids (nitric, hot concentrated sulfuric), sulfides, and fast-flowing aerated or chlorinated water (erosion-corrosion).

Sustainability4

Producing a kilogram of Cu-DXP-R290 takes about 57 MJ of energy and emits 3.8 kg of CO₂ — less than 52% of copper alloy grades. Typical recycled content is 35%.

Embodied Energy (primary production)57 MJ/kg24,506 BTU/lb
Embodied Carbon (primary production)3.8 kg CO₂/kg
Embodied Water250 L/kg30 gal/lb
Typical Recycled Content35%

Manufacturability8

Cu-DXP-R290's machinability is poor (25/100, worse than 86% of copper alloy grades); weldability excellent (88/100); formability fair (45/100).

MachinabilityPoor25/100
Machinability Rating (AISI 1212 = 100 %)30%
WeldabilityExcellent88/100
Formability (cold)Fair45/100
CastabilityVery good70/100
Brazeability / SolderabilityExcellent95/100
PolishabilityVery good80/100
Anodizing Responsen/a — copper is not anodized; use electroplating (Ni/Sn/Cr), tin coating or chemical patination/lacquering instead.

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with Cu-DXP-R290

Is Cu-DXP easy to machine?

Gummy and non-free-cutting (~20 % of AISI 1212): use sharp positive-rake tools, high speed, low feed and generous coolant; half-hard temper cuts cleaner than annealed.

Can Cu-DXP be welded?

Excellent for oxy-fuel, TIG and MIG because the residual phosphorus prevents hydrogen embrittlement; preheat heavy sections to offset the high thermal conductivity.

Can Cu-DXP be formed, bent or molded?

In R220 it bends, expands, flares and deep-draws readily; interstage anneal above ~450 °C after heavy cold work, and avoid ammonia-bearing environments on cold-worked parts.

What surface finishes work on Cu-DXP?

Not anodizable — solder/braze, tin or nickel plate, or polish and lacquer; bare surfaces patinate to brown/green in service.

Cu-DXP chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
Presidual deoxidizing phosphorus, upper deoxidized range (above Cu-DHP)0.04 – 0.070.05
Agcounted as copper≤ 0.02—
Biimpurity limit≤ 5×10⁻⁴—
Pbimpurity limit≤ 0.01—
Oeffectively deoxidized≤ 0—
CuCu + Ag, min 99.90 % per EN refined-copper practice≥ 99.9 (balance)—

Cu-DXP-R290 — frequently asked

What is Cu-DXP-R290 used for?

Cu-DXP-R290 is typically used for tube and fitting manufacture, brazed assemblies and hydraulic lines. In short: highly formable copper tube stock; braze-friendly deoxidized copper; DHP/DLP alternative grade.

What is the yield strength of Cu-DXP-R290?

Cu-DXP-R290 has a typical yield strength of 260 MPa (37.7 ksi) and a tensile strength of 315 MPa (45.7 ksi) — stronger than 55% of copper alloy grades. Strength varies by condition: see the 9 listed tempers.

Is Cu-DXP-R290 easy to machine?

Not especially — machinability is rated poor (25/100, worse than 86% of copper alloy grades). Gummy and non-free-cutting (~20 % of AISI 1212): use sharp positive-rake tools, high speed, low feed and generous coolant; half-hard temper cuts cleaner than annealed.

Can Cu-DXP-R290 be welded?

Yes — weldability is rated excellent (88/100). Excellent for oxy-fuel, TIG and MIG because the residual phosphorus prevents hydrogen embrittlement; preheat heavy sections to offset the high thermal conductivity.

What surface finishes work on Cu-DXP-R290?

Not anodizable — solder/braze, tin or nickel plate, or polish and lacquer; bare surfaces patinate to brown/green in service.

Can Cu-DXP-R290 be formed, bent or molded?

In R220 it bends, expands, flares and deep-draws readily; interstage anneal above ~450 °C after heavy cold work, and avoid ammonia-bearing environments on cold-worked parts.

What is the maximum service temperature of Cu-DXP-R290?

Cu-DXP-R290 is rated for continuous use to about 120°C (248 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between Cu-DXP-R220 and Cu-DXP-R360?

R220 is the default condition — default for tube, fittings and deep-drawn parts: maximum ductility, easiest bending and expansion. R360: pick for heavily drawn rod, wire or high-strength small-bore tube where maximum cold-worked strength is needed. Yield strength is 70 MPa in R220 versus 320 MPa in R360.

Sources

  1. EN 1976 — Copper and copper alloys: cast unwrought copper products — CEN (2012)
  2. EN 1978 — Copper cathodes — CEN (1998)
  3. EN 1173 — Copper and copper alloys: material condition designation — CEN (2008)
  4. EN 12735-1 / EN 1057 — Seamless round copper tubes for air conditioning, refrigeration and water — CEN (2016)
  5. ASM Handbook Vol. 2 — Properties and Selection: Nonferrous Alloys — ASM International (1990)
  6. C12200 / Cu-DHP phosphorus-deoxidized copper alloy data — Copper Development Association (copper.org) (2023)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.