FabDigitFabDigit

Copper Alloy C44400-H02

Supply condition

UNS C44400

H02 = half hard

Choose the half-hard cold-rolled strip when 345 MPa yield and 25 % elongation must coexist, as in tube-sheet fittings and moderately bent formed parts.

High cost $$$$

Values for the H02 condition

Other C44400 tempers and conditions

C44400 is listed in 9 conditions; see the grade overview at C44400.

Compare all 9 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
Annealed to 0.050 mm grain size
Pick the coarser 0.050 mm annealed grain for the best deep drawing, flaring and tube expansion, accepting a rougher, orange-peel-prone surface; 340 MPa tensile at 68% elongation.1253406860 HB25 % IACS
O61Default
Annealed
Use the annealed soft tube for condenser and heat-exchanger work requiring tube expansion and bending: 65% elongation and best formability at the lowest yield strength of 140 MPa.1403556565 HB25 % IACS
Annealed to 0.025 mm grain size
Choose the 0.025 mm grain-size annealed strip when surface quality must stay smooth after moderate deep drawing; 372 MPa tensile and 60% elongation with less orange peel than coarser grain.1603726075 HB25 % IACS
Light drawn then stress relieved
Pick lightly drawn then low-temperature stress-relieved tube for condensers in ammonia-bearing or high residual-stress service to cut stress-corrosion cracking; 390 MPa tensile, 52% elongation.1803905284 HB25 % IACS
Light drawn tube
Choose lightly drawn tube when dimensional accuracy and stiffness must exceed the soft temper while still allowing moderate roller expansion; 400 MPa tensile with 50% elongation.1954005090 HB25 % IACS
Drawn, general purpose
Use the general-purpose drawn tube or rod as the standard supply condition, trading 430 MPa tensile and 250 MPa yield against 40% elongation for remaining forming operations.25043040100 HB25 % IACS
Quarter hard
Choose the quarter-hard flat product when some bending is still needed but strength must exceed the annealed temper; 275 MPa yield and 415 MPa tensile with elongation limited to 40%.2754154095 HB25 % IACS
H02This page
Half hard
Choose the half-hard cold-rolled strip when 345 MPa yield and 25 % elongation must coexist, as in tube-sheet fittings and moderately bent formed parts.34546225115 HB25 % IACS
Full hard
Use the fully cold-worked hard temper for maximum strength and spring action at 400 MPa yield; elongation falls to 15 % and stress-corrosion sensitivity is the highest of the tempers.40051715135 HB24 % IACS

What is C44400-H02?

C44400-H02 is C44400 supplied in the H02 condition — choose the half-hard cold-rolled strip when 345 MPa yield and 25 % elongation must coexist, as in tube-sheet fittings and moderately bent formed parts. C44400-H02 has a yield strength of 345 MPa (50 ksi) and a tensile strength of 462 MPa (67 ksi) — stronger than 73% of copper alloy grades. Elongation at break is 25% and the elastic modulus is 110 GPa (16 Msi). C44400-H02 has a density of 8.53 g/cm³ (0.308 lb/in³), lighter than 62% of copper alloy grades. It melts at 900°C (1,652 °F). O61 is the default condition FabDigit quotes; H02 is available on request or by drawing note.

Limitations

  • Limited service temperature — 175°C (347 °F), worse than 92% of copper alloy grades

C44400-H02 properties

Typical room-temperature values for C44400-H02; 20 are specific to this condition. Other listed values are C44400 reference data and may not represent this condition. Bars are the position among copper alloy grades.

Physical3

C44400-H02 has a density of 8.53 g/cm³ (0.308 lb/in³), lighter than 62% of copper alloy grades. It melts at 900°C (1,652 °F).

Density8.53 g/cm³0.31 lb/in³
Melting Point (Solidus)900°C1,652 °F
Liquidus Temperature935°C1,715 °F

Mechanical14

C44400-H02 has a yield strength of 345 MPa (50 ksi) and a tensile strength of 462 MPa (67 ksi) — stronger than 73% of copper alloy grades. Elongation at break is 25% and the elastic modulus is 110 GPa (16 Msi).

Elastic (Young's) Modulus110 GPa16 Msi
Shear Modulus41 GPa5.9 Msi
Bulk Modulus112 GPa16.2 Msi
Poisson's Ratio0.34
Tensile Strength (Ultimate)462 MPa67 ksi
Yield Strength (0.2% offset)345 MPa50 ksi
Elongation at Break25%
Reduction in Area50%
Shear Strength295 MPa42.8 ksi
Fatigue Strength (Endurance Limit)152 MPa22 ksi
Charpy V-Notch Impact (RT)45 J33.2 ft·lbf
Hardness, Brinell115 HB
Hardness, Rockwell B70 HRB
Hardness, Vickers120 HV

Thermal6

C44400-H02 is rated for continuous service to 175°C (347 °F). It conducts heat at 110 W/m·K (63.6 BTU/hr·ft·°F), better than 58% of copper alloy grades. Thermal expansion is 20.2 µm/m·K (11.2 µin/in·°F).

Thermal Conductivity110 W/m·K63.6 BTU/hr·ft·°F
Specific Heat Capacity377 J/kg·K0.09 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)20.2 µm/m·K11.2 µin/in·°F
Latent Heat of Fusion170 J/g73.1 BTU/lb
Max Service Temperature (continuous)175°C347 °F
Min Service Temperature-200°C-328 °F

Electrical3

C44400-H02 conducts electricity at 25 % IACS, better than 59% of copper alloy grades.

Electrical Conductivity25 % IACS
Electrical Resistivity6.9×10⁻⁸ Ω·m2.72 µΩ·in
Magnetic Responsenon-magnetic

Chemical & Environmental3

Corrosion resistance is good (63/100), better than 52% of copper alloy grades.

Galvanic Potential (seawater, vs SCE)-0.28 V
Corrosion ResistanceGood63/100
Chemical Resistance Summary—

Sustainability4

Producing a kilogram of C44400-H02 takes about 62 MJ of energy and emits 4 kg of CO₂ — more than 76% of copper alloy grades. Typical recycled content is 40%.

Embodied Energy (primary production)62 MJ/kg26,655 BTU/lb
Embodied Carbon (primary production)4 kg CO₂/kg
Embodied Water300 L/kg35.9 gal/lb
Typical Recycled Content40%

Manufacturability7

C44400-H02's machinability is poor (34/100, worse than 53% of copper alloy grades); weldability fair (42/100); formability fair (45/100).

MachinabilityPoor34/100
Machinability Rating (AISI 1212 = 100 %)33%
WeldabilityFair42/100
Formability (cold)Fair45/100
Brazeability / SolderabilityExcellent90/100
PolishabilityVery good75/100
Anodizing Response—

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with C44400-H02

Is C44400 easy to machine?

Machinability is about 30% of free-cutting brass; chips are continuous and tend to smear, so use sharp positive-rake tools, high cutting speed and flood emulsion coolant.

Can C44400 be welded?

Soft soldering is excellent and brazing is good; fusion welding (GTAW/GMAW) is only fair, with clear zinc volatilisation and hot-cracking tendency, so keep heat input low and extract zinc fume.

Can C44400 be formed, bent or molded?

Cold formability in the annealed condition is excellent, allowing deep drawing, tube expansion and flaring. Stress-relieve at 250–300 °C after heavy cold work to prevent stress-corrosion cracking in ammonia environments.

What surface finishes work on C44400?

Not anodizable. Can be polished and tin- or nickel-plated, or passivated with benzotriazole (BTA) and sealed with clear lacquer to hold brightness.

C44400 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
CuAg may be counted as Cu70 – 7371.5
Sn0.9 – 1.21.05
SbSb-type dezincification inhibitor (C44300 As, C44500 P)0.02 – 0.10.05
Pb≤ 0.07—
Fe≤ 0.06—
Znbalance, about 27.5%balance—

C44400-H02 — frequently asked

What is C44400-H02 used for?

C44400-H02 is typically used for condenser tubes, heat exchanger tubes and marine piping. In short: dezincification-resistant Admiralty brass; non-arsenical inhibited grade; condenser tube standard.

What is the yield strength of C44400-H02?

C44400-H02 has a typical yield strength of 345 MPa (50 ksi) and a tensile strength of 462 MPa (67 ksi) — stronger than 73% of copper alloy grades. Strength varies by condition: see the 9 listed tempers.

Is C44400-H02 easy to machine?

Not especially — machinability is rated poor (34/100, worse than 53% of copper alloy grades). Machinability is about 30% of free-cutting brass; chips are continuous and tend to smear, so use sharp positive-rake tools, high cutting speed and flood emulsion coolant.

Can C44400-H02 be welded?

With care — weldability is rated fair (42/100). Soft soldering is excellent and brazing is good; fusion welding (GTAW/GMAW) is only fair, with clear zinc volatilisation and hot-cracking tendency, so keep heat input low and extract zinc fume.

What surface finishes work on C44400-H02?

Not anodizable. Can be polished and tin- or nickel-plated, or passivated with benzotriazole (BTA) and sealed with clear lacquer to hold brightness.

Can C44400-H02 be formed, bent or molded?

Cold formability in the annealed condition is excellent, allowing deep drawing, tube expansion and flaring. Stress-relieve at 250–300 °C after heavy cold work to prevent stress-corrosion cracking in ammonia environments.

What is the maximum service temperature of C44400-H02?

C44400-H02 is rated for continuous use to about 175°C (347 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between C44400-O61 and C44400-H04?

O61 is the default condition — use the annealed soft tube for condenser and heat-exchanger work requiring tube expansion and bending: 65% elongation and best formability at the lowest yield strength of 140 MPa. H04: use the fully cold-worked hard temper for maximum strength and spring action at 400 MPa yield; elongation falls to 15 % and stress-corrosion sensitivity is the highest of the tempers. Yield strength is 140 MPa in O61 versus 400 MPa in H04.

Sources

  1. ASTM B111/B111M — Copper and Copper-Alloy Seamless Condenser Tubes — ASTM (2021)
  2. ASTM B171 / B543 (condenser plate & welded tube) — ASTM (2018)
  3. CDA UNS C44400 Admiralty Metal (Inhibited) alloy datasheet — Copper Development Association (2023)
  4. ASM Handbook Vol.2 — Properties of Nonferrous Alloys — ASM International (1990)
  5. ASM Handbook Vol.13B — Corrosion: Materials (Cu alloys in seawater) — ASM International (2005)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.