FabDigitFabDigit

Nickel Alloy N12MV-AC (Spheroidize annealed)

Heat-treated state

UNS J30012, N10001 · ASTM A494 N12MV

Only for non-critical or mechanical (non-acid) service — interdendritic Mo-rich carbides lower ductility and intergranular corrosion resistance.

High cost $$$$

Values for the AC condition

Other N12MV tempers and conditions

N12MV is listed in 4 conditions; see the grade overview at N12MV.

Compare all 4 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
SADefault
Solution annealed and quenched
Standard supply condition for corrosion service: ~1100–1180 °C solution anneal, rapid quench to dissolve Ni-Mo carbides/intermetallics.3505851015 HRC1.3 % IACS
As-welded deposit
Condition after minor weld repair when re-solution annealing is impractical; HAZ is susceptible to knife-line and intergranular attack in acids.3505507210 HB1.3 % IACS
hot isostatically pressed then solution annealed
For pressure-retaining or radiographic-quality castings where microporosity must be closed; slightly higher ductility and toughness.3556101415 HRC1.3 % IACS
ACThis page
Spheroidize annealed
Only for non-critical or mechanical (non-acid) service — interdendritic Mo-rich carbides lower ductility and intergranular corrosion resistance.3605205220 HB1.3 % IACS

What is N12MV-AC?

N12MV-AC is N12MV heat treated to AC — only for non-critical or mechanical (non-acid) service — interdendritic Mo-rich carbides lower ductility and intergranular corrosion resistance. N12MV-AC has a yield strength of 360 MPa (52.2 ksi) and a tensile strength of 520 MPa (75.4 ksi) — weaker than 57% of nickel alloy grades. Elongation at break is 5% and the elastic modulus is 216 GPa (31.3 Msi). N12MV-AC has a density of 9.24 g/cm³ (0.334 lb/in³), heavier than 99% of nickel alloy grades. It melts at 1,320°C (2,408 °F). SA is the default condition FabDigit quotes; AC is available on request or by drawing note.

Limitations

  • Limited ductility — 5%, worse than 93% of nickel alloy grades
  • Limited formability — 5/100, worse than 91% of nickel alloy grades
  • Needs corrosion protection — 65/100, worse than 85% of nickel alloy grades
  • Hard to polish — 60/100, worse than 84% of nickel alloy grades
  • Difficult to weld — 33/100, worse than 77% of nickel alloy grades

N12MV-AC properties

Typical room-temperature values for N12MV-AC; 21 are specific to this condition. Other listed values are N12MV reference data and may not represent this condition. Bars are the position among nickel alloy grades.

Physical3

N12MV-AC has a density of 9.24 g/cm³ (0.334 lb/in³), heavier than 99% of nickel alloy grades. It melts at 1,320°C (2,408 °F).

Density9.24 g/cm³0.33 lb/in³
Melting Point (Solidus)1,320°C2,408 °F
Liquidus Temperature1,350°C2,462 °F

Mechanical15

N12MV-AC has a yield strength of 360 MPa (52.2 ksi) and a tensile strength of 520 MPa (75.4 ksi) — weaker than 57% of nickel alloy grades. Elongation at break is 5% and the elastic modulus is 216 GPa (31.3 Msi).

Elastic (Young's) Modulus216 GPa31.3 Msi
Shear Modulus82 GPa11.9 Msi
Bulk Modulus190 GPa27.6 Msi
Poisson's Ratio0.31
Tensile Strength (Ultimate)520 MPa75.4 ksi
Yield Strength (0.2% offset)360 MPa52.2 ksi
Elongation at Break5%
Reduction in Area6%
Shear Strength370 MPa53.7 ksi
Fatigue Strength (Endurance Limit)210 MPa30.5 ksi
Charpy V-Notch Impact (RT)18 J13.3 ft·lbf
Hardness, Brinell220 HB
Hardness, Rockwell B98 HRB
Hardness, Rockwell C15 HRC
Hardness, Vickers232 HV

Thermal5

N12MV-AC is rated for continuous service to 540°C (1,004 °F). It conducts heat at 10.5 W/m·K (6.07 BTU/hr·ft·°F), worse than 73% of nickel alloy grades. Thermal expansion is 10.3 µm/m·K (5.72 µin/in·°F).

Thermal Conductivity10.5 W/m·K6.1 BTU/hr·ft·°F
Specific Heat Capacity375 J/kg·K0.09 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)10.3 µm/m·K5.7 µin/in·°F
Max Service Temperature (continuous)540°C1,004 °F
Min Service Temperature-196°C-321 °F

Electrical3

N12MV-AC conducts electricity at 1.3 % IACS, worse than 89% of nickel alloy grades.

Electrical Conductivity1.3 % IACS
Electrical Resistivity1.38×10⁻⁶ Ω·m54.3 µΩ·in
Magnetic Responsenon-magnetic

Chemical & Environmental3

Corrosion resistance is good (65/100), worse than 85% of nickel alloy grades.

Galvanic Potential (seawater, vs SCE)-0.15 V
Corrosion ResistanceGood65/100
Chemical Resistance SummaryExcellent in all concentrations of hot HCl, sulfuric, phosphoric, acetic and other reducing acids and in dry HCl gas; unsuitable for nitric acid, ferric/cupric chloride, wet chlorine or any oxidizing salt; welds and 650–870 °C exposure risk knife-line/intergranular attack unless re-solution annealed.

Sustainability4

Producing a kilogram of N12MV-AC takes about 175 MJ of energy and emits 14 kg of CO₂ — more than 65% of nickel alloy grades. Typical recycled content is 40%.

Embodied Energy (primary production)175 MJ/kg75,237 BTU/lb
Embodied Carbon (primary production)14 kg CO₂/kg
Embodied Water250 L/kg30 gal/lb
Typical Recycled Content40%

Manufacturability8

N12MV-AC's machinability is not recommended (12/100, worse than 86% of nickel alloy grades); weldability poor (33/100); formability not recommended (5/100).

MachinabilityNot recommended12/100
Machinability Rating (AISI 1212 = 100 %)10%
WeldabilityPoor33/100
Formability (cold)Not recommended5/100
CastabilityGood55/100
Brazeability / SolderabilityFair45/100
PolishabilityGood60/100
Anodizing Responsen/a — nickel alloy, not anodized; electropolishing or pickling/passivation used instead

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with N12MV-AC

Is N12MV easy to machine?

Machine slow and heavy: rigid setup, positive-rake carbide, ~15–25 m/min, generous feed and flood coolant to avoid work hardening and glazing.

Can N12MV be welded?

GTAW/SMAW with matching Ni-Mo (ENiMo-1/ERNiMo-2 type) filler, low heat input, no preheat; re-solution anneal and quench after welding for acid service.

Can N12MV be formed, bent or molded?

Sand or investment cast only; wide freezing range demands strong risering, chills and controlled pour to limit shrinkage porosity — not a wrought/formable product.

What surface finishes work on N12MV?

Sand blast, grind and pickle in nitric-free (HCl/HF-type) solution — nitric pickling attacks Ni-Mo alloys; electropolish for clean process surfaces, no anodizing.

N12MV chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
Mo26 – 3329
Fe4 – 65
V0.2 – 0.60.35
C≤ 0.120.08
Cr≤ 10.5
Si≤ 10.6
Mn≤ 10.6
Cu≤ 0.5—
P≤ 0.04—
S≤ 0.03—
Nibalance—

N12MV-AC — frequently asked

What is N12MV-AC used for?

N12MV-AC is typically used for HCl service pump housings, chemical reactor valves and reducing-acid piping fittings. In short: best cast alloy for HCl; chromium-free Ni-Mo casting; not for oxidizing acids.

What is the yield strength of N12MV-AC?

N12MV-AC has a typical yield strength of 360 MPa (52.2 ksi) and a tensile strength of 520 MPa (75.4 ksi) — weaker than 57% of nickel alloy grades. Strength varies by condition: see the 4 listed tempers.

Is N12MV-AC easy to machine?

Not especially — machinability is rated not recommended (12/100, worse than 86% of nickel alloy grades). Machine slow and heavy: rigid setup, positive-rake carbide, ~15–25 m/min, generous feed and flood coolant to avoid work hardening and glazing.

Can N12MV-AC be welded?

Not readily — weldability is rated poor (33/100). GTAW/SMAW with matching Ni-Mo (ENiMo-1/ERNiMo-2 type) filler, low heat input, no preheat; re-solution anneal and quench after welding for acid service.

What surface finishes work on N12MV-AC?

Sand blast, grind and pickle in nitric-free (HCl/HF-type) solution — nitric pickling attacks Ni-Mo alloys; electropolish for clean process surfaces, no anodizing.

Can N12MV-AC be formed, bent or molded?

Sand or investment cast only; wide freezing range demands strong risering, chills and controlled pour to limit shrinkage porosity — not a wrought/formable product.

What is the maximum service temperature of N12MV-AC?

N12MV-AC is rated for continuous use to about 540°C (1,004 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between N12MV-SA and N12MV-AC?

SA is the default condition — standard supply condition for corrosion service: ~1100–1180 °C solution anneal, rapid quench to dissolve Ni-Mo carbides/intermetallics. AC: only for non-critical or mechanical (non-acid) service — interdendritic Mo-rich carbides lower ductility and intergranular corrosion resistance. Yield strength is 350 MPa in SA versus 360 MPa in AC.

Sources

  1. ASTM A494/A494M — Castings, Nickel and Nickel Alloy — ASTM International (2023)
  2. ASM Handbook Vol. 2 — Properties and Selection: Nonferrous Alloys and Special-Purpose Materials — ASM International (1990)
  3. Ni-Mo alloy B / B-2 physical and corrosion data — Haynes International (2020)
  4. UNS N30012 / J30012 alloy record — SAE/ASTM Metals & Alloys in the Unified Numbering System (2017)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.