FabDigitFabDigit

Copper Alloy C19700-O60

Temper

UNS C19700

O60 = soft annealed

Choose for deep drawing or severe forming where strength is developed later by forming/stress relief.

High cost $$$$

Values for the O60 condition

Other C19700 tempers and conditions

C19700 is listed in 8 conditions; see the grade overview at C19700.

Compare all 8 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
O60This page
Soft annealed
Choose for deep drawing or severe forming where strength is developed later by forming/stress relief.1302753035 HRB82 % IACS
Quarter hard
Choose when forming severity is high but some added stiffness over annealed strip is needed.2503151895 HB81 % IACS
Half hard
Choose for stamped contacts and terminals needing tight-radius bends with moderate spring force.3103501265 HRB80 % IACS
H04Default
Full hard
The standard stocked temper: best all-round balance of spring force, formability and 80% IACS conductivity for connectors and lead frames.385415672 HRB80 % IACS
Extra hard
Choose when higher contact force is required and bends are gentle or in the good-way (GW) direction.425450478 HRB79 % IACS
Mill hardened, full hard
Choose when improved bend formability and low springback drift are needed at a given strength; low-temperature stress relief after rolling raises conductivity and relaxation resistance.4404605140 HB84 % IACS
Spring hard
Choose for spring contacts and clips needing high yield and good stress-relaxation resistance with simple forming.455480382 HRB79 % IACS
Extra spring hard
Highest strength temper — pick for maximum contact normal force in flat or lightly formed parts.490510285 HRB78 % IACS

What is C19700-O60?

C19700-O60 is C19700 in the O60 temper — choose for deep drawing or severe forming where strength is developed later by forming/stress relief. C19700-O60 has a yield strength of 130 MPa (18.9 ksi) and a tensile strength of 275 MPa (39.9 ksi) — weaker than 77% of copper alloy grades. Elongation at break is 30% and the elastic modulus is 120 GPa (17.4 Msi). C19700-O60 has a density of 8.89 g/cm³ (0.321 lb/in³), heavier than 72% of copper alloy grades. It melts at 1,075°C (1,967 °F). H04 is the default condition FabDigit quotes; O60 is available on request or by drawing note.

Advantages

  • Forms and bends easily — 88/100, better than 87% of copper alloy grades
  • Conducts heat well — 325 W/m·K (187.8 BTU/hr·ft·°F), better than 85% of copper alloy grades
  • High electrical conductivity — 82 % IACS, better than 85% of copper alloy grades
  • Ductile — tolerates forming and impact — 30%, better than 75% of copper alloy grades

Limitations

  • Difficult to machine — 22/100, worse than 94% of copper alloy grades
  • Low strength — 130 MPa (18.9 ksi), worse than 77% of copper alloy grades

C19700-O60 properties

Typical room-temperature values for C19700-O60; 11 are specific to this condition. Other listed values are C19700 reference data and may not represent this condition. Bars are the position among copper alloy grades.

Physical3

C19700-O60 has a density of 8.89 g/cm³ (0.321 lb/in³), heavier than 72% of copper alloy grades. It melts at 1,075°C (1,967 °F).

Density8.89 g/cm³0.32 lb/in³
Melting Point (Solidus)1,075°C1,967 °F
Liquidus Temperature1,085°C1,985 °F

Mechanical11

C19700-O60 has a yield strength of 130 MPa (18.9 ksi) and a tensile strength of 275 MPa (39.9 ksi) — weaker than 77% of copper alloy grades. Elongation at break is 30% and the elastic modulus is 120 GPa (17.4 Msi).

Elastic (Young's) Modulus120 GPa17.4 Msi
Shear Modulus45 GPa6.5 Msi
Bulk Modulus138 GPa20 Msi
Poisson's Ratio0.33
Tensile Strength (Ultimate)275 MPa39.9 ksi
Yield Strength (0.2% offset)130 MPa18.9 ksi
Elongation at Break30%
Shear Strength250 MPa36.3 ksi
Fatigue Strength (Endurance Limit)110 MPa16 ksi
Hardness, Rockwell B35 HRB
Hardness, Vickers75 HV

Thermal6

C19700-O60 is rated for continuous service to 200°C (392 °F). It conducts heat at 325 W/m·K (187.8 BTU/hr·ft·°F), better than 85% of copper alloy grades. Thermal expansion is 17.6 µm/m·K (9.78 µin/in·°F).

Thermal Conductivity325 W/m·K188 BTU/hr·ft·°F
Specific Heat Capacity385 J/kg·K0.09 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)17.6 µm/m·K9.8 µin/in·°F
Latent Heat of Fusion205 J/g88.1 BTU/lb
Max Service Temperature (continuous)200°C392 °F
Min Service Temperature-196°C-321 °F

Electrical3

C19700-O60 conducts electricity at 82 % IACS, better than 85% of copper alloy grades.

Electrical Conductivity82 % IACS
Electrical Resistivity2.16×10⁻⁸ Ω·m0.85 µΩ·in
Magnetic Responsenon-magnetic

Chemical & Environmental3

Corrosion resistance is good (58/100), worse than 76% of copper alloy grades.

Galvanic Potential (seawater, vs SCE)-0.3 V
Corrosion ResistanceGood58/100
Chemical Resistance SummaryGood in fresh/marine water, neutral salts and most organics; attacked by ammonia/amines, oxidizing acids (HNO₃), sulfides and strong oxidizers; tarnishes in air and requires plating for stable contact resistance.

Sustainability4

Producing a kilogram of C19700-O60 takes about 57 MJ of energy and emits 3.8 kg of CO₂ — less than 52% of copper alloy grades. Typical recycled content is 30%.

Embodied Energy (primary production)57 MJ/kg24,506 BTU/lb
Embodied Carbon (primary production)3.8 kg CO₂/kg
Embodied Water260 L/kg31.2 gal/lb
Typical Recycled Content30%

Manufacturability7

C19700-O60's machinability is poor (22/100, worse than 94% of copper alloy grades); weldability fair (45/100); formability excellent (88/100).

MachinabilityPoor22/100
Machinability Rating (AISI 1212 = 100 %)20%
WeldabilityFair45/100
Formability (cold)Excellent88/100
Brazeability / SolderabilityExcellent95/100
PolishabilityVery good80/100
Anodizing Responsen/a — copper alloy; use tin, nickel, silver or gold plating instead of anodizing

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with C19700-O60

Is C19700 easy to machine?

Gummy like pure copper (≈20% of AISI 1212) — use sharp positive-rake tools, high speed, flood coolant; stamping and progressive-die blanking are the normal removal routes.

Can C19700 be welded?

Excellent for resistance, laser and ultrasonic welding of thin strip; fusion arc welding is impractical due to high thermal conductivity and P/Mg loss.

Can C19700 be formed, bent or molded?

Formability drops sharply above H04 — specify GW/BW minimum bend radius (typically 0–1t at H02, 2–4t at H08/H10) and consider stress relief after forming to cut springback drift.

What surface finishes work on C19700?

Not anodizable; standard finishes are hot-dip or reflow tin, nickel underplate with gold or silver flash for contacts, or bare with anti-tarnish (BTA) coating.

C19700 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
Feforms fine Fe-rich/phosphide precipitates0.3 – 1.20.6
P0.1 – 0.40.2
Mgimproves stress-relaxation resistance0.01 – 0.20.05
Pbimpurity limit≤ 0.03—
Znimpurity limit≤ 0.2—
CuCu + named elements ≥ 99.8%; Cu ≥ 99.0% incl. Agbalance—

C19700-O60 — frequently asked

What is C19700-O60 used for?

C19700-O60 is typically used for springs and connectors, electrical terminals and relay contacts. In short: high-conductivity spring copper; 80% IACS at 415 MPa; stress-relaxation resistant strip.

What is the yield strength of C19700-O60?

C19700-O60 has a typical yield strength of 130 MPa (18.9 ksi) and a tensile strength of 275 MPa (39.9 ksi) — weaker than 77% of copper alloy grades. Strength varies by condition: see the 8 listed tempers.

Is C19700-O60 easy to machine?

Not especially — machinability is rated poor (22/100, worse than 94% of copper alloy grades). Gummy like pure copper (≈20% of AISI 1212) — use sharp positive-rake tools, high speed, flood coolant; stamping and progressive-die blanking are the normal removal routes.

Can C19700-O60 be welded?

With care — weldability is rated fair (45/100). Excellent for resistance, laser and ultrasonic welding of thin strip; fusion arc welding is impractical due to high thermal conductivity and P/Mg loss.

What surface finishes work on C19700-O60?

Not anodizable; standard finishes are hot-dip or reflow tin, nickel underplate with gold or silver flash for contacts, or bare with anti-tarnish (BTA) coating.

Can C19700-O60 be formed, bent or molded?

Formability drops sharply above H04 — specify GW/BW minimum bend radius (typically 0–1t at H02, 2–4t at H08/H10) and consider stress relief after forming to cut springback drift.

What is the maximum service temperature of C19700-O60?

C19700-O60 is rated for continuous use to about 200°C (392 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between C19700-H04 and C19700-O60?

H04 is the default condition — the standard stocked temper: best all-round balance of spring force, formability and 80% IACS conductivity for connectors and lead frames. O60: choose for deep drawing or severe forming where strength is developed later by forming/stress relief. Yield strength is 385 MPa in H04 versus 130 MPa in O60.

Sources

  1. CDA Alloy Datasheet C19700 — Copper Development Association (copper.org) (2023)
  2. ASTM B888/B888M — Copper Alloy Strip for Electrical Connectors — ASTM International (2020)
  3. ASM Handbook Vol. 2 — Properties and Selection: Nonferrous Alloys — ASM International (1990)
  4. ASM Handbook Vol. 13B — Corrosion: Materials (Copper) — ASM International (2005)
  5. GB/T 2059 / GB/T 2040 (2017)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.