FabDigitFabDigit

Copper Alloy C18600-TM01

Precip hard

UNS C18600

TM01 = mill hardened, low strength level

Intermediate mill-hardened level when TM00 lacks contact force but TM02 will not form.

High cost $$$$

Values for the TM01 condition

Other C18600 tempers and conditions

C18600 is listed in 11 conditions; see the grade overview at C18600.

Compare all 11 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
Solution heat treated
Choose for deep forming, heavy machining or fabrication before a customer ageing cycle.952504060 HB42 % IACS
Half hard
Cold-rolled strip for parts that will be formed then precipitation aged in-house.30036012105 HB45 % IACS
Mill hardened
Mill-hardened strip for connector contacts requiring very tight bend radii.35042018118 HB82 % IACS
Full hard
Maximum cold-worked strength before ageing; used where a subsequent age hardening step follows.3804206125 HB45 % IACS
TD02 and precipitation hardened
Rod/bar temper giving a good balance of conductivity and moderate strength for electrodes and machined contacts.39046018140 HB80 % IACS
TM01This page
Mill hardened, low strength level
Intermediate mill-hardened level when TM00 lacks contact force but TM02 will not form.39045015133 HB80 % IACS
Mill hardened, half hard
Most-formable of the high-force connector tempers: pick when 90° bends with small radii are needed at ~500 MPa strength.45050012148 HB80 % IACS
TD04 and precipitation hardened
Standard rod/bar condition for resistance-welding electrodes and high-load current-carrying parts.46052014155 HB78 % IACS
TM04Default
Mill hardened, full hard
Default stocked connector-strip temper: highest contact force and stress relaxation resistance still compatible with moderate forming.5105508160 HB78 % IACS
Mill hardened, extra hard
For flat springs and contacts needing maximum force where bends are gentle or along the good bend direction.560590610 HRC76 % IACS
Mill hardened, spring hard
Top mill-hardened strength for miniature high-force contacts; bending capability is marginal.600630413 HRC74 % IACS

What is C18600-TM01?

C18600-TM01 is C18600 in the TM01 condition — intermediate mill-hardened level when TM00 lacks contact force but TM02 will not form. C18600-TM01 has a yield strength of 390 MPa (56.6 ksi) and a tensile strength of 450 MPa (65.3 ksi) — stronger than 78% of copper alloy grades. Elongation at break is 15% and the elastic modulus is 128 GPa (18.6 Msi). C18600-TM01 has a density of 8.89 g/cm³ (0.321 lb/in³), heavier than 72% of copper alloy grades. It melts at 1,070°C (1,958 °F). TM04 is the default condition FabDigit quotes; TM01 is available on request or by drawing note.

Advantages

  • High service temperature — 350°C (662 °F), better than 95% of copper alloy grades
  • High electrical conductivity — 80 % IACS, better than 84% of copper alloy grades
  • Conducts heat well — 310 W/m·K (179.1 BTU/hr·ft·°F), better than 83% of copper alloy grades
  • High strength — 390 MPa (56.6 ksi), better than 78% of copper alloy grades
  • Forms and bends easily — 62/100, better than 77% of copper alloy grades

Limitations

  • Difficult to machine — 20/100, worse than 98% of copper alloy grades

C18600-TM01 properties

Typical room-temperature values for C18600-TM01; 21 are specific to this condition. Other listed values are C18600 reference data and may not represent this condition. Bars are the position among copper alloy grades.

Physical3

C18600-TM01 has a density of 8.89 g/cm³ (0.321 lb/in³), heavier than 72% of copper alloy grades. It melts at 1,070°C (1,958 °F).

Density8.89 g/cm³0.32 lb/in³
Melting Point (Solidus)1,070°C1,958 °F
Liquidus Temperature1,080°C1,976 °F

Mechanical13

C18600-TM01 has a yield strength of 390 MPa (56.6 ksi) and a tensile strength of 450 MPa (65.3 ksi) — stronger than 78% of copper alloy grades. Elongation at break is 15% and the elastic modulus is 128 GPa (18.6 Msi).

Elastic (Young's) Modulus128 GPa18.6 Msi
Shear Modulus48 GPa7 Msi
Bulk Modulus138 GPa20 Msi
Poisson's Ratio0.34
Tensile Strength (Ultimate)450 MPa65.3 ksi
Yield Strength (0.2% offset)390 MPa56.6 ksi
Elongation at Break15%
Shear Strength280 MPa40.6 ksi
Fatigue Strength (Endurance Limit)165 MPa23.9 ksi
Charpy V-Notch Impact (RT)72 J53.1 ft·lbf
Hardness, Brinell133 HB
Hardness, Rockwell B74 HRB
Hardness, Vickers140 HV

Thermal6

C18600-TM01 is rated for continuous service to 350°C (662 °F). It conducts heat at 310 W/m·K (179.1 BTU/hr·ft·°F), better than 83% of copper alloy grades. Thermal expansion is 17 µm/m·K (9.44 µin/in·°F).

Thermal Conductivity310 W/m·K179 BTU/hr·ft·°F
Specific Heat Capacity385 J/kg·K0.09 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)17 µm/m·K9.4 µin/in·°F
Latent Heat of Fusion205 J/g88.1 BTU/lb
Max Service Temperature (continuous)350°C662 °F
Min Service Temperature-200°C-328 °F

Electrical3

C18600-TM01 conducts electricity at 80 % IACS, better than 84% of copper alloy grades.

Electrical Conductivity80 % IACS
Electrical Resistivity2.16×10⁻⁸ Ω·m0.85 µΩ·in
Magnetic Responsenon-magnetic

Chemical & Environmental3

Corrosion resistance is good (62/100), worse than 57% of copper alloy grades.

Galvanic Potential (seawater, vs SCE)-0.22 V
Corrosion ResistanceGood62/100
Chemical Resistance SummaryGood in fresh/sea water, non-oxidising acids and neutral atmospheres; attacked by ammonia and amines (stress corrosion), oxidising acids (HNO₃), sulphides and mercury compounds; oxidises above ~200 °C in air.

Sustainability4

Producing a kilogram of C18600-TM01 takes about 57 MJ of energy and emits 3.6 kg of CO₂ — less than 52% of copper alloy grades. Typical recycled content is 35%.

Embodied Energy (primary production)57 MJ/kg24,506 BTU/lb
Embodied Carbon (primary production)3.6 kg CO₂/kg
Embodied Water250 L/kg30 gal/lb
Typical Recycled Content35%

Manufacturability7

C18600-TM01's machinability is poor (20/100, worse than 98% of copper alloy grades); weldability fair (40/100); formability good (62/100).

MachinabilityPoor20/100
Machinability Rating (AISI 1212 = 100 %)20%
WeldabilityFair40/100
Formability (cold)Good62/100
Brazeability / SolderabilityVery good70/100
PolishabilityVery good75/100
Anodizing Responsen/a — copper alloys are not anodised; use electroplating (Ni, Sn, Ag, Au) or chromate/benzotriazole tarnish inhibition.

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with C18600-TM01

Is C18600 easy to machine?

Gummy and abrasive-free: use sharp positive-rake carbide, high speed, light-to-moderate feed and flood coolant; rating about 20 % of free-cutting brass, chip breaking is the main problem.

Can C18600 be welded?

Resistance and electron-beam/laser welding work best; GTAW is possible with Cu-Cr or Cu-Si filler but the HAZ over-ages and loses 30–50 % of strength — re-age if properties matter.

Can C18600 be formed, bent or molded?

Form in TB00/H02 for deep draws; mill-hardened TM02 bends to roughly 1–2 t good-way while TM04 and above need larger radii and bad-way bends should be avoided.

What surface finishes work on C18600?

Not anodisable — barrel or reel-to-reel plate with Ni underlayer plus Sn, Ag or Au for contacts; chromium-bearing oxide needs an activating acid dip before plating and a benzotriazole rinse prevents tarnish on bare parts.

C18600 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
Crprincipal precipitation-hardening element of the C186xx chromium copper family0.4 – 1.20.8
Feimpurity limit≤ 0.10.03
Siimpurity/deoxidiser residual≤ 0.10.03
CuCu + named elements ≥ 99.5 %; verify exact registered limits against the current CDA/UNS registration and ASTM B888 for connector stripbalance—

C18600-TM01 — frequently asked

What is C18600-TM01 used for?

C18600-TM01 is typically used for welding electrodes, connectors and electrical contacts. In short: mill-hardened chromium copper; 78 % IACS at 510 MPa; no heat treatment needed.

What is the yield strength of C18600-TM01?

C18600-TM01 has a typical yield strength of 390 MPa (56.6 ksi) and a tensile strength of 450 MPa (65.3 ksi) — stronger than 78% of copper alloy grades. Strength varies by condition: see the 11 listed tempers.

Is C18600-TM01 easy to machine?

Not especially — machinability is rated poor (20/100, worse than 98% of copper alloy grades). Gummy and abrasive-free: use sharp positive-rake carbide, high speed, light-to-moderate feed and flood coolant; rating about 20 % of free-cutting brass, chip breaking is the main problem.

Can C18600-TM01 be welded?

With care — weldability is rated fair (40/100). Resistance and electron-beam/laser welding work best; GTAW is possible with Cu-Cr or Cu-Si filler but the HAZ over-ages and loses 30–50 % of strength — re-age if properties matter.

What surface finishes work on C18600-TM01?

Not anodisable — barrel or reel-to-reel plate with Ni underlayer plus Sn, Ag or Au for contacts; chromium-bearing oxide needs an activating acid dip before plating and a benzotriazole rinse prevents tarnish on bare parts.

Can C18600-TM01 be formed, bent or molded?

Form in TB00/H02 for deep draws; mill-hardened TM02 bends to roughly 1–2 t good-way while TM04 and above need larger radii and bad-way bends should be avoided.

What is the maximum service temperature of C18600-TM01?

C18600-TM01 is rated for continuous use to about 350°C (662 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between C18600-TM04 and C18600-TB00?

TM04 is the default condition — default stocked connector-strip temper: highest contact force and stress relaxation resistance still compatible with moderate forming. TB00: choose for deep forming, heavy machining or fabrication before a customer ageing cycle. Yield strength is 510 MPa in TM04 versus 95 MPa in TB00.

Sources

  1. ASTM B888/B888M — Copper Alloy Strip for Use in Manufacture of Electrical Connectors or Spring Contacts — ASTM International (2020)
  2. ASTM B601 — Temper Designations for Copper and Copper Alloys — ASTM International (2019)
  3. ASTM B224 — Classification of Coppers — ASTM International (2021)
  4. CDA/UNS Copper Alloy Property Datasheets (C182xx–C186xx chromium coppers) — Copper Development Association (2023)
  5. ASM Handbook Vol. 2 — Properties and Selection: Nonferrous Alloys and Special-Purpose Materials — ASM International (1990)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.