FabDigitFabDigit

Stainless Steel 1.4035 +QT800

Heat-treated state

EN 1.4035

+QT800 = quenched and tempered, Rm 800–950 MPa

Use the high-strength quench-and-temper level (Rm 800–950 MPa, 265 HB) for fasteners and drive parts under higher loads that still require some toughness, with elongation limited to 10%.

Standard cost $$

Values for the +QT800 condition

Other 1.4035 tempers and conditions

1.4035 is listed in 8 conditions; see the grade overview at 1.4035.

Compare all 8 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
+ADefault
Annealed
Pick the standard soft annealed stock (≤245 HB) for roughing and finishing on automatic lathes, with hardening and tempering done afterwards; machinability rates 70 but corrosion resistance is modest.40070014215 HB—
Peeled / centreless ground bar
Use annealed bar that is peeled and centreless ground when shaft semi-finished parts or long slender turnings need high dimensional accuracy; strength stays at the annealed 700 MPa, 215 HB level.4007001417 HRC3.1 % IACS
Quenched and tempered, Rm 650–850 MPa
Choose the high-temperature-tempered condition (Rm 650–850 MPa) for medium-strength shafts and structural parts where toughness and machinability, rated 62, outweigh hardness.5007501420 HRC3 % IACS
Quenched and tempered, Rm 700–850 MPa
Pick this quenched and tempered delivery state (Rm 700–850 MPa) for turned valve stems and pump shafts needing both strength and wear resistance; machinability falls to 58.5607801223 HRC3 % IACS
Cold drawn
Choose annealed-then-cold-drawn bright bar for small turned parts needing tight tolerance and a bright surface with steadier cutting; residual stress is high and distortion risk rises.650850825 HRC3.1 % IACS
+QT800This page
Quenched and tempered, Rm 800–950 MPa
Use the high-strength quench-and-temper level (Rm 800–950 MPa, 265 HB) for fasteners and drive parts under higher loads that still require some toughness, with elongation limited to 10%.6508701027 HRC3 % IACS
Hardened & tempered to 43–48 HRC
Choose hardening with a temper near 300 °C to 43–48 HRC for valve plugs, wear bushings and blunt-edged tooling; wear and toughness are balanced but machinability drops to 30.1,2001,450445 HRC—
Hardened & low tempered to 50–54 HRC
Use quenching from 1020–1050 °C with a 180–250 °C temper to 50–54 HRC for cutlery, gauges and cutting or wear parts; this is the hardest state, with the lowest toughness and corrosion resistance.1,4501,750252 HRC—

What is 1.4035 +QT800?

1.4035 +QT800 is 1.4035 heat treated to +QT800 — use the high-strength quench-and-temper level (Rm 800–950 MPa, 265 HB) for fasteners and drive parts under higher loads that still require some toughness, with elongation limited to 10%. 1.4035 +QT800 has a yield strength of 650 MPa (94.3 ksi) and a tensile strength of 870 MPa (126 ksi) — stronger than 90% of stainless steel grades. Elongation at break is 10% and the elastic modulus is 215 GPa (31.2 Msi). 1.4035 +QT800 has a density of 7.7 g/cm³ (0.278 lb/in³), lighter than 83% of stainless steel grades. It melts at 1,420°C (2,588 °F). +A is the default condition FabDigit quotes; +QT800 is available on request or by drawing note.

Advantages

  • Conducts heat well — 30 W/m·K (17.3 BTU/hr·ft·°F), better than 99% of stainless steel grades
  • High electrical conductivity — 3 % IACS, better than 95% of stainless steel grades
  • Easy to machine — 52/100, better than 91% of stainless steel grades
  • High strength — 650 MPa (94.3 ksi), better than 90% of stainless steel grades

Limitations

  • Difficult to weld — 8/100, worse than 100% of stainless steel grades
  • Limited ductility — 10%, worse than 98% of stainless steel grades
  • Hard to polish — 45/100, worse than 96% of stainless steel grades
  • Low fracture toughness — 45 MPa·√m (41 ksi·√in), worse than 95% of stainless steel grades
  • Limited formability — 10/100, worse than 95% of stainless steel grades

1.4035 +QT800 properties

Typical room-temperature values for 1.4035 +QT800; 22 are specific to this condition. Other listed values are 1.4035 reference data and may not represent this condition. Bars are the position among stainless steel grades.

Physical3

1.4035 +QT800 has a density of 7.7 g/cm³ (0.278 lb/in³), lighter than 83% of stainless steel grades. It melts at 1,420°C (2,588 °F).

Density7.7 g/cm³0.28 lb/in³
Melting Point (Solidus)1,420°C2,588 °F
Liquidus Temperature1,480°C2,696 °F

Mechanical16

1.4035 +QT800 has a yield strength of 650 MPa (94.3 ksi) and a tensile strength of 870 MPa (126 ksi) — stronger than 90% of stainless steel grades. Elongation at break is 10% and the elastic modulus is 215 GPa (31.2 Msi).

Elastic (Young's) Modulus215 GPa31.2 Msi
Shear Modulus82 GPa11.9 Msi
Bulk Modulus160 GPa23.2 Msi
Poisson's Ratio0.28
Tensile Strength (Ultimate)870 MPa126 ksi
Yield Strength (0.2% offset)650 MPa94.3 ksi
Elongation at Break10%
Reduction in Area25%
Compressive Strength670 MPa97.2 ksi
Shear Strength530 MPa76.9 ksi
Fatigue Strength (Endurance Limit)380 MPa55.1 ksi
Fracture Toughness (K_IC)45 MPa·√m41 ksi·√in
Charpy V-Notch Impact (RT)10 J7.4 ft·lbf
Hardness, Brinell265 HB
Hardness, Rockwell B96 HRB
Hardness, Vickers280 HV

Thermal6

1.4035 +QT800 is rated for continuous service to 400°C (752 °F). It conducts heat at 30 W/m·K (17.3 BTU/hr·ft·°F), better than 99% of stainless steel grades. Thermal expansion is 10.5 µm/m·K (5.83 µin/in·°F).

Thermal Conductivity30 W/m·K17.3 BTU/hr·ft·°F
Specific Heat Capacity460 J/kg·K0.11 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)10.5 µm/m·K5.8 µin/in·°F
Latent Heat of Fusion260 J/g112 BTU/lb
Max Service Temperature (continuous)400°C752 °F
Min Service Temperature-20°C-4 °F

Electrical3

1.4035 +QT800 conducts electricity at 3 % IACS, better than 95% of stainless steel grades.

Electrical Conductivity3 % IACS
Electrical Resistivity5.8×10⁻⁷ Ω·m22.8 µΩ·in
Magnetic Responseferromagnetic

Chemical & Environmental3

Corrosion resistance is fair (42/100), worse than 90% of stainless steel grades.

Galvanic Potential (seawater, vs SCE)-0.35 V
Corrosion ResistanceFair42/100
Chemical Resistance Summary—

Sustainability4

Producing a kilogram of 1.4035 +QT800 takes about 52 MJ of energy and emits 4.3 kg of CO₂ — less than 76% of stainless steel grades. Typical recycled content is 55%.

Embodied Energy (primary production)52 MJ/kg22,356 BTU/lb
Embodied Carbon (primary production)4.3 kg CO₂/kg
Embodied Water190 L/kg22.8 gal/lb
Typical Recycled Content55%

Manufacturability7

1.4035 +QT800's machinability is fair (52/100, better than 91% of stainless steel grades); weldability not recommended (8/100); formability not recommended (10/100).

MachinabilityFair52/100
Machinability Rating (AISI 1212 = 100 %)52%
WeldabilityNot recommended8/100
Formability (cold)Not recommended10/100
Brazeability / SolderabilityFair40/100
PolishabilityFair45/100
Anodizing Response—

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with 1.4035 +QT800

Is 1.4035 easy to machine?

Turning behaviour is best in the annealed condition, at roughly 70 % of AISI 1212, with manganese sulfides breaking the chips; run an emulsion with extreme-pressure additives. Once hardened above 45 HRC, use CBN or ceramic inserts, or switch to grinding.

Can 1.4035 be welded?

Essentially not weldable: the combination of high carbon and sulfur promotes hot cracking and martensitic cold cracking. If a joint is unavoidable, preheat to 250–300 °C, use 309 or 410NiMo filler and temper immediately after welding; joint properties cannot be guaranteed.

Can 1.4035 be formed, bent or molded?

Cold formability is poor and limited to minor straightening and knurling. Hot work between 1100 °C and 850 °C, then cool slowly and anneal at 750–800 °C with furnace cooling.

What surface finishes work on 1.4035?

After quenching and tempering, pickle and passivate per ASTM A967 to restore the passive film. Sulfide inclusions leave pits in mirror-polished surfaces; electropolishing, PVD or electroless nickel improve both appearance and corrosion resistance.

1.4035 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
C0.43 – 0.50.46
Si≤ 10.4
Mnhigher Mn ties up S as MnS≤ 1.50.8
P≤ 0.040.03
Sdeliberate free-machining addition0.15 – 0.350.25
Cr12.5 – 14.513.5
Mooptional / residual per EN 10088-3≤ 0.6—
Febalance—

1.4035 +QT800 — frequently asked

What is 1.4035 +QT800 used for?

1.4035 +QT800 is typically used for valve components, turned cutlery parts and fasteners. In short: free-machining 420-type stainless; best-machining martensitic grade; not for welded assemblies.

What is the yield strength of 1.4035 +QT800?

1.4035 +QT800 has a typical yield strength of 650 MPa (94.3 ksi) and a tensile strength of 870 MPa (126 ksi) — stronger than 90% of stainless steel grades. Strength varies by condition: see the 8 listed tempers.

Is 1.4035 +QT800 easy to machine?

Reasonably — machinability is rated fair (52/100, better than 91% of stainless steel grades). Turning behaviour is best in the annealed condition, at roughly 70 % of AISI 1212, with manganese sulfides breaking the chips; run an emulsion with extreme-pressure additives. Once hardened above 45 HRC, use CBN or ceramic inserts, or switch to grinding.

Can 1.4035 +QT800 be welded?

Not readily — weldability is rated not recommended (8/100). Essentially not weldable: the combination of high carbon and sulfur promotes hot cracking and martensitic cold cracking. If a joint is unavoidable, preheat to 250–300 °C, use 309 or 410NiMo filler and temper immediately after welding; joint properties cannot be guaranteed.

What surface finishes work on 1.4035 +QT800?

After quenching and tempering, pickle and passivate per ASTM A967 to restore the passive film. Sulfide inclusions leave pits in mirror-polished surfaces; electropolishing, PVD or electroless nickel improve both appearance and corrosion resistance.

Can 1.4035 +QT800 be formed, bent or molded?

Cold formability is poor and limited to minor straightening and knurling. Hot work between 1100 °C and 850 °C, then cool slowly and anneal at 750–800 °C with furnace cooling.

What is the maximum service temperature of 1.4035 +QT800?

1.4035 +QT800 is rated for continuous use to about 400°C (752 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

Sources

  1. EN 10088-3 Stainless steels — Semi-finished products, bars, rods, sections — CEN (2014)
  2. EN 10088-1 Stainless steels — List of stainless steels — CEN (2014)
  3. ASM Handbook Vol.1 — Properties and Selection: Irons, Steels — ASM International (1990)
  4. Free-machining martensitic stainless bar (X46CrS13 / 420F) data sheets — European long-product mills (2023)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.