FabDigit

MED610

MED610 is a rigid, transparent acrylic-based PolyJet photopolymer certified for short-term skin and mucosal contact and validated for EtO and gamma sterilization.

High cost $$$$

Reference datasheet — MED610 is not in the instant-quote catalog. Upload your part and an engineer will quote it in this grade or suggest the closest stocked equivalent.

Values for the GLOSSY condition

MED610 grades and fills

MED610 is supplied in one standard condition, GLOSSY. GLOSSY is the default FabDigit quotes; the values on this page are for it.

Supply forms, finishes and certifications

Ways MED610 is supplied — form, process route, surface or paperwork — without a datasheet of their own. The property values above apply.

OptionWhat it isType
MATTE
Printed fully encapsulated in support materialSurface finish
ETO
EtO-sterilizedCertification
GAMMA
Gamma / e-beam irradiatedCertification

What is MED610?

MED610 is a rigid, transparent acrylic-based PolyJet photopolymer certified for short-term skin and mucosal contact and validated for EtO and gamma sterilization. Engineers specify it for clear, dimensionally accurate patient-contact models built directly on Objet30 Prime/Dental, J5 MediJet and Connex systems, in glossy or matte finish; default values are 57 MPa tensile strength, 17% elongation and Shore D 84. The resin softens above roughly 50 °C, so steam autoclaving is ruled out, and prolonged UV exposure yellows it. VeroClear is the nearest clear PolyJet grade where biocompatibility is not required. MED610 has a density of 1.18 g/cm³ (0.0424 lb/in³), lighter than 52% of polymer grades. Its glass-transition temperature is 53°C (127 °F). MED610 has a tensile strength of 57 MPa (8.27 ksi), stronger than 65% of polymer grades. Elongation at break is 17% and the elastic modulus is 2.5 GPa (0.363 Msi).

What is MED610 used for?

  • surgical guides
  • dental models
  • medical device prototypes
  • anatomical models

Advantages

  • Polishes to a fine finish — 70/100, better than 77% of polymer grades

Limitations

  • Limited service temperature — 45°C (113 °F), worse than 98% of polymer grades
  • Absorbs moisture — dry before molding — 1.3%, worse than 88% of polymer grades
  • Needs corrosion protection — 70/100, worse than 78% of polymer grades
  • Degrades in UV without stabilisers — 25/100, worse than 76% of polymer grades

MED610 properties

Typical room-temperature values for MED610-GLOSSY; bars are the position among polymer grades.

Physical6

MED610 has a density of 1.18 g/cm³ (0.0424 lb/in³), lighter than 52% of polymer grades. Its glass-transition temperature is 53°C (127 °F).

Density1.18 g/cm³0.04 lb/in³
Glass Transition (Tg)53°C127 °F
Water Absorption (24 h)1.3%
Water Absorption (Saturation)1.8%
Refractive Index1.52
Light Transmission88%

Mechanical10

MED610 has a tensile strength of 57 MPa (8.27 ksi), stronger than 65% of polymer grades. Elongation at break is 17% and the elastic modulus is 2.5 GPa (0.363 Msi).

Elastic (Young's) Modulus2.5 GPa0.36 Msi
Poisson's Ratio0.35
Tensile Strength (Ultimate)57 MPa8.3 ksi
Elongation at Break17%
Compressive Strength85 MPa12.3 ksi
Flexural Strength90 MPa13.1 ksi
Flexural Modulus2.7 GPa0.39 Msi
Izod Impact, Notched25 J/m0.47 ft·lbf/in
Hardness, Shore D84 Shore D
Hardness, Rockwell M80 HRM

Thermal7

MED610 is rated for continuous service to 45°C (113 °F). It conducts heat at 0.2 W/m·K (0.116 BTU/hr·ft·°F), worse than 56% of polymer grades. Thermal expansion is 90 µm/m·K (50 µin/in·°F).

Thermal Conductivity0.2 W/m·K0.12 BTU/hr·ft·°F
Specific Heat Capacity1,500 J/kg·K0.36 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)90 µm/m·K50 µin/in·°F
Max Service Temperature (continuous)45°C113 °F
Min Service Temperature-20°C-4 °F
Heat Deflection Temp. @ 0.45 MPa47°C117 °F
Heat Deflection Temp. @ 1.8 MPa43°C109 °F

Chemical & Environmental3

Corrosion resistance is very good (70/100), worse than 78% of polymer grades. UV resistance is poor.

Corrosion ResistanceVery good70/100
UV / Weathering ResistancePoor25/100
Chemical Resistance SummaryGood against dilute aqueous solutions, saline and mild disinfectants; attacked/softened by acetone, MEK, strong solvents and concentrated alcohols with prolonged exposure; absorbs water and slowly loses stiffness on long immersion; yellows under UV.

Sustainability3

Producing a kilogram of MED610 takes about 110 MJ of energy and emits 5.5 kg of CO₂ — more than 64% of polymer grades. Typical recycled content is 0%.

Embodied Energy (primary production)110 MJ/kg47,292 BTU/lb
Embodied Carbon (primary production)5.5 kg CO₂/kg
Typical Recycled Content0%

Manufacturability3

MED610's machinability is good (55/100, worse than 64% of polymer grades).

MachinabilityGood55/100
PolishabilityVery good70/100
Processing Melt Temperature (typ.)72°C162 °F

Common Calculations4

Specific Strength (UTS / density)calculated49 kN·m/kg
Specific Stiffness (E / density)calculated2.1 MN·m/kg
Thermal Diffusivitycalculated0.1 mm²/s
Thermal Shock Resistance Indexcalculated0

Values are nominal handbook figures for design screening. Certified mill or lot data ships with every FabDigit order on request.

Strength versus weight in the polymer family

Yield strength against density for every polymer grade FabDigit runs. MED610 is highlighted; hover a dot for its name, or open the interactive family chart.

0.1110100123Density (g/cm³)Yield strength (MPa) — log scale

Working with MED610

Is MED610 easy to machine?

Light drilling, trimming and thread-tapping are possible with sharp tools and low feed; keep parts cool since heat above ~50 °C softens and distorts them.

Can MED610 be welded?

Not weldable by heat; join with cyanoacrylate or UV-cure acrylic adhesive, using only biocompatible adhesives on patient-contact parts.

Can MED610 be formed, bent or molded?

Not moldable — parts are built directly on PolyJet machines (Objet30 Prime/Dental, J5 MediJet, Connex); orient critical features away from support to control clarity and accuracy.

MED610 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
acrylic monomer (isobornyl / difunctionaUV-curable acrylate monomer blend30 – 6045
photoinitiatorfree-radical UV initiator0.5 – 31.5
additives (stabilizers, surfactants)residual ash content 0.02–0.1 %0.5 – 31.5
acrylate oligomer (urethane/epoxy acrylabackbone oligomer providing rigidity≥ 25 (balance)

What surface finishes work on MED610?

Remove support by waterjet/NaOH-free medical cleaning cycle, then wet-sand and acrylic-polish for transparency; sterilize by EtO or gamma — avoid steam autoclave and prolonged UV exposure.

Equivalent designations

Standards and trade names that resolve to MED610 in FabDigit's catalog. Equivalence is nominal — check the exact specification when certification matters.

Also called
10993-1 / USP Class VI biocompatible

How much does MED610 cost?

MED610 is a high-cost polymer ($$$$), pricier than about 78% of the materials FabDigit quotes. Part price depends far more on geometry, tolerance and quantity than on the raw stock — upload a CAD file for a live quote.

MED610 — frequently asked

What is MED610 used for?

MED610 is typically used for surgical guides, dental models, medical device prototypes and anatomical models. In short: biocompatible clear PolyJet resin; etO and gamma sterilizable; rigid but not autoclavable.

What is the tensile strength of MED610?

MED610 has a typical tensile strength of 57 MPa (8.27 ksi) — stronger than 65% of polymer grades.

Is MED610 easy to machine?

Reasonably — machinability is rated good (55/100, worse than 64% of polymer grades). Light drilling, trimming and thread-tapping are possible with sharp tools and low feed; keep parts cool since heat above ~50 °C softens and distorts them.

Can MED610 be welded?

Not weldable by heat; join with cyanoacrylate or UV-cure acrylic adhesive, using only biocompatible adhesives on patient-contact parts.

What surface finishes work on MED610?

Remove support by waterjet/NaOH-free medical cleaning cycle, then wet-sand and acrylic-polish for transparency; sterilize by EtO or gamma — avoid steam autoclave and prolonged UV exposure.

Can MED610 be formed, bent or molded?

Not moldable — parts are built directly on PolyJet machines (Objet30 Prime/Dental, J5 MediJet, Connex); orient critical features away from support to control clarity and accuracy.

What is the maximum service temperature of MED610?

MED610 is rated for continuous use to about 45°C (113 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

How much does MED610 cost?

MED610 is a high-cost polymer ($$$$), pricier than about 78% of the materials FabDigit quotes. Part price depends far more on geometry, tolerance and quantity than on the raw stock — upload a CAD file for a live quote.

Sources

  1. MED610 PolyJet Biocompatible Clear Material Data Sheet — Stratasys (2023)
  2. ISO 10993-1 Biological evaluation of medical devices — Part 1 — ISO (2018)
  3. USP <88> Biological Reactivity Tests, In Vivo (Class VI) — USP (2022)
  4. ASTM D638 / D790 / D256 / D648 / D570 plastics test methods — ASTM (2022)
  5. PolyJet (2025)

Property data is compiled from published supplier and standards handbooks and normalised for comparison; hardness values on non-Brinell scales are converted approximately for charting only. Manufacturability limits are FabDigit quote-engine defaults and may be relaxed by engineering review. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.