FabDigit

Dental Resin · grade

Dental Resin-LT

Properties of the LT condition, compared with the other Dental Resin grades.

Pick for occlusal splints, night guards and retainers needing >30 day intraoral use, clarity and fracture resistance.

What is Dental Resin-LT?

Dental Resin-LT is Dental Resin in the LT grade — pick for occlusal splints, night guards and retainers needing >30 day intraoral use, clarity and fracture resistance. Dental Resin-LT has a yield strength of 48 MPa (6.96 ksi) and a tensile strength of 48 MPa (6.96 ksi) — weaker than 57% of polymer grades. Elongation at break is 12% and the elastic modulus is 2.2 GPa (0.319 Msi). Dental Resin-LT has a density of 1.14 g/cm³ (0.0412 lb/in³), lighter than 60% of polymer grades. Its glass-transition temperature is 78°C (172 °F). Standard is the default condition FabDigit quotes; LT is available on request or by drawing note.

Advantages

  • Polishes to a fine finish — 88/100, better than 95% of polymer grades

Limitations

  • Limited formability — 5/100, worse than 95% of polymer grades
  • Difficult to weld — 5/100, worse than 90% of polymer grades
  • Absorbs moisture — dry before molding — 1.2%, worse than 87% of polymer grades
  • Low fracture toughness — 1.1 MPa·√m (1 ksi·√in), worse than 80% of polymer grades
  • Limited service temperature — 70°C (158 °F), worse than 78% of polymer grades

Dental Resin-LT properties

Typical room-temperature values for Dental Resin-LT — 11 properties are specific to this condition; the rest are grade-level values shared by every Dental Resin grade. Each bar shows where the value sits among the polymer grades in FabDigit's library — further right is higher.

Physical6

Dental Resin-LT has a density of 1.14 g/cm³ (0.0412 lb/in³), lighter than 60% of polymer grades. Its glass-transition temperature is 78°C (172 °F).

Density1.14 g/cm³0.04 lb/in³
Glass Transition (Tg)78°C172 °F
Water Absorption (24 h)1.2%
Water Absorption (Saturation)2%
Refractive Index1.51
Light Transmission88%

Mechanical16

Dental Resin-LT has a yield strength of 48 MPa (6.96 ksi) and a tensile strength of 48 MPa (6.96 ksi) — weaker than 57% of polymer grades. Elongation at break is 12% and the elastic modulus is 2.2 GPa (0.319 Msi).

Elastic (Young's) Modulus2.2 GPa0.32 Msi
Shear Modulus0.8 GPa0.12 Msi
Bulk Modulus3 GPa0.38 Msi
Poisson's Ratio0.35
Tensile Strength (Ultimate)48 MPa7 ksi
Yield Strength (0.2% offset)48 MPa7 ksi
Elongation at Break12%
Compressive Strength130 MPa18.9 ksi
Compressive Modulus2.3 GPa0.33 Msi
Flexural Strength78 MPa11.3 ksi
Flexural Modulus1.7 GPa0.25 Msi
Shear Strength40 MPa5.8 ksi
Fracture Toughness (K_IC)1.1 MPa·√m1 ksi·√in
Izod Impact, Notched35 J/m0.66 ft·lbf/in
Hardness, Shore D82 Shore D
Hardness, Rockwell M85 HRM

Thermal10

Dental Resin-LT is rated for continuous service to 70°C (158 °F). It conducts heat at 0.2 W/m·K (0.116 BTU/hr·ft·°F), worse than 56% of polymer grades. Thermal expansion is 100 µm/m·K (55.6 µin/in·°F).

Thermal Conductivity0.2 W/m·K0.12 BTU/hr·ft·°F
Specific Heat Capacity1,500 J/kg·K0.36 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)100 µm/m·K55.6 µin/in·°F
Max Service Temperature (continuous)70°C158 °F
Min Service Temperature-20°C-4 °F
Heat Deflection Temp. @ 0.45 MPa68°C154 °F
Heat Deflection Temp. @ 1.8 MPa60°C140 °F
Flammability (UL 94)HB (not flame retardant; typical unfilled dental photopolymer)
Limiting Oxygen Index19%
Max Service Temperature (short-term)134°C273 °F

Electrical6

Dental Resin-LT is an electrical insulator with a dielectric strength of 15 kV/mm (381 V/mil) and a resistivity of 1×10¹³ Ω·m.

Electrical Resistivity1×10¹³ Ω·m3.94×10²⁰ µΩ·in
Dielectric Strength15 kV/mm381 V/mil
Dielectric Constant (1 MHz)3.4
Dissipation Factor (1 MHz)0.03
Volume Resistivity1×10¹⁵ Ω·cm
Surface Resistivity1×10¹⁵ Ω

Chemical & Environmental3

Corrosion resistance is excellent (85/100), better than 63% of polymer grades. UV resistance is fair.

Corrosion ResistanceExcellent85/100
UV / Weathering ResistanceFair35/100
Chemical Resistance SummaryGood against water, saliva, dilute acids/bases, alcohols used for disinfection (short contact); attacked or swelled by ketones, esters, chlorinated solvents and hot alkalis; prolonged IPA soaking softens the network and long-term wet ageing lowers strength.

Sustainability4

Producing a kilogram of Dental Resin-LT takes about 110 MJ of energy and emits 5.5 kg of CO₂ — more than 64% of polymer grades. Typical recycled content is 0%.

Embodied Energy (primary production)110 MJ/kg47,292 BTU/lb
Embodied Carbon (primary production)5.5 kg CO₂/kg
Embodied Water200 L/kg24 gal/lb
Typical Recycled Content0%

Manufacturability6

Dental Resin-LT's machinability is good (60/100, better than 51% of polymer grades); weldability not recommended (5/100); formability not recommended (5/100).

MachinabilityGood60/100
WeldabilityNot recommended5/100
Formability (cold)Not recommended5/100
PolishabilityExcellent88/100
Mold Shrinkage1%
Mold Temperature (typ.)30°C86 °F

Values are nominal handbook figures for design screening. Certified mill or lot data ships with every FabDigit order on request.

Other Dental Resin grades and fills

Dental Resin is also supplied in 10 other conditions. The full side-by-side table is on the Dental Resin overview.

Working with Dental Resin-LT

Is Dental Resin easy to machine?

Trim supports and adjust with carbide/tungsten dental burs at low speed and light pressure; the cured thermoset chips and loads abrasives, so use dust extraction and avoid heat build-up that discolours the part.

Can Dental Resin be welded?

Not weldable — a thermoset; repair or join only with the same photopolymer plus flash cure, or with dental adhesive/PMMA cold-cure resin.

Can Dental Resin be formed, bent or molded?

Formed only during printing: control layer height 25–100 µm, orient to reduce cross-section per layer, wash 3–10 min in IPA (or TPM) and post-cure under 385/405 nm at 60–80 °C exactly per the datasheet — under-cure ruins biocompatibility and strength, over-cure embrittles and shrinks.

What surface finishes work on Dental Resin?

Sand 400→1500 grit wet, then pumice and dental high-gloss paste on a rag wheel; glaze or light-cure varnish improves stain resistance, and non-clear parts can be shaded with light-cure stains.

Dental Resin chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
urethane dimethacrylate (UDMA) oligomerprimary crosslinking oligomer20 – 6040
Bis-EMA / ethoxylated Bis-GMAaromatic dimethacrylate, raises modulus/Tg0 – 3015
reactive diluent monomers (TEGDMA, HEMA,viscosity control10 – 4022
silanised silica / barium glass filler0 % in clear splint/guide grades, 30–50 % in crown grades0 – 5020
photoinitiator (TPO / BAPO / camphorquin405 nm / 385 nm sensitised0.3 – 31.2
pigments, opacifiers, stabilisers, UV blshade matching and cure-depth control0.1 – 31

Dental Resin-LT — frequently asked

What is Dental Resin-LT used for?

Dental Resin-LT is typically used for dental crowns and bridges, surgical guides, dental models and dies, splints and night guards, temporary restorations and denture bases and gingiva masks. In short: biocompatible dental SLA resin.

What is the yield strength of Dental Resin-LT?

Dental Resin-LT has a typical yield strength of 48 MPa (6.96 ksi) and a tensile strength of 48 MPa (6.96 ksi) — weaker than 57% of polymer grades. Strength varies by condition: see the 11 listed tempers.

Is Dental Resin-LT easy to machine?

Reasonably — machinability is rated good (60/100, better than 51% of polymer grades). Trim supports and adjust with carbide/tungsten dental burs at low speed and light pressure; the cured thermoset chips and loads abrasives, so use dust extraction and avoid heat build-up that discolours the part.

Can Dental Resin-LT be welded?

Not readily — weldability is rated not recommended (5/100). Not weldable — a thermoset; repair or join only with the same photopolymer plus flash cure, or with dental adhesive/PMMA cold-cure resin.

What surface finishes work on Dental Resin-LT?

Sand 400→1500 grit wet, then pumice and dental high-gloss paste on a rag wheel; glaze or light-cure varnish improves stain resistance, and non-clear parts can be shaded with light-cure stains.

Can Dental Resin-LT be formed, bent or molded?

Formed only during printing: control layer height 25–100 µm, orient to reduce cross-section per layer, wash 3–10 min in IPA (or TPM) and post-cure under 385/405 nm at 60–80 °C exactly per the datasheet — under-cure ruins biocompatibility and strength, over-cure embrittles and shrinks.

What is the maximum service temperature of Dental Resin-LT?

Dental Resin-LT is rated for continuous use to about 70°C (158 °F), and briefly to 134°C. Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

Can FabDigit make parts in Dental Resin-LT?

Yes — Dental Resin-LT is available for injection molding and 3D printing with instant online pricing. Upload a STEP file to get a price and a DFM check.

Sources

  1. ISO 10993-1 Biological evaluation of medical devicesISO (2018)
  2. ISO 4049 Dentistry — Polymer-based restorative materialsISO (2019)
  3. ISO 20795-1 Dentistry — Base polymers, Part 1: Denture base polymersISO (2013)
  4. Dental material datasheets (Surgical Guide, Dental LT Clear, Denture Base/Teeth, Permanent Crown)Formlabs (2024)
  5. NextDent 3D printing resin technical data sheets3D Systems / NextDent (2024)
  6. FREEPRINT / SHERAprint dental resin datasheetsDETAX / SHERA (2023)
  7. Craig's Restorative Dental MaterialsElsevier (2019)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.