FabDigitFabDigit

Aluminum 1200-H22

Temper

AA 1200 · UNS A91200 · EN AW-1200, AW 1200 · JIS A1200 · BS 1C

H22 = strain hardened and partially annealed, quarter hard

Stabilized quarter-hard coil with better ductility than H12 at the same strength class — good for roll-formed profiles.

Sheet metalBudget cost $

Values for the H22 condition

Other 1200 tempers and conditions

1200 is listed in 13 conditions; see the grade overview at 1200.

Compare all 13 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
Annealed
Pick for maximum ductility: deep drawing, spinning, hand-formed sheet, foil and chemical-tank linings.32904023 HB59 % IACS
Slightly strain hardened
Near-O ductility with slightly higher strength; common designation on EN 485 sheet and coil for forming work.35953224 HB59 % IACS
Strain hardened from hot working only
1200 hot-fabricated (extrusion/plate) with incidental strain hardening from forming, meeting guaranteed minimum mechanical limits; slightly stronger than O temper with near-full ductility.40902824 HB58 % IACS
As fabricated
As-fabricated 1200 commercially pure aluminium (hot-worked/extruded, no controlled strain hardening or thermal treatment); mechanical properties not guaranteed but typically near-annealed to slightly work-hardened.45953025 HB59 % IACS
H22This page
Strain hardened and partially annealed, quarter hard
Stabilized quarter-hard coil with better ductility than H12 at the same strength class — good for roll-formed profiles.751051628 HB58 % IACS
Strain hardened, quarter hard
Light temper for parts that still need bending or roll forming but more stiffness than O.851051428 HB58 % IACS
Strain hardened and partially annealed, half hard
Half-hard temper with more residual bendability than H14; widely used for European sheet/coil and roofing strip.951251133 HB57 % IACS
Strain hardened, half hard
The standard stocked sheet/coil temper: good balance of moderate strength, workable bend radii and full corrosion/conductivity performance.105120932 HB57 % IACS
Strain hardened and partially annealed, three-quarter hard
Three-quarter hard stabilized strip for stiff panels that still need mild forming.120145739 HB57 % IACS
Strain hardened, three-quarter hard
Choose for flat panels, name plates and shallow-formed parts needing more stiffness with limited bending.125140638 HB57 % IACS
Strain hardened and partially annealed, full hard
Full-hard stabilized thin strip/foil stock where flatness and consistent hardness matter more than ductility.145160544 HB57 % IACS
Strain hardened, full hard
Highest practical cold-worked strength; used for flat strip, fin stock and foil where no forming is required.150160444 HB57 % IACS
Strain hardened, extra hard
Extra-hard thin strip/foil and wire where maximum as-rolled strength and springiness are wanted.165175347 HB56 % IACS

What is 1200-H22?

1200-H22 is 1200 in the H22 temper — stabilized quarter-hard coil with better ductility than H12 at the same strength class — good for roll-formed profiles. 1200-H22 has a yield strength of 75 MPa (10.9 ksi) and a tensile strength of 105 MPa (15.2 ksi) — weaker than 91% of aluminum grades. Elongation at break is 16% and the elastic modulus is 69 GPa (10 Msi). 1200-H22 has a density of 2.71 g/cm³ (0.0979 lb/in³), heavier than 51% of aluminum grades. It melts at 645°C (1,193 °F).

Advantages

  • Conducts heat well — 228 W/m·K (131.7 BTU/hr·ft·°F), better than 95% of aluminum grades
  • High electrical conductivity — 58 % IACS, better than 95% of aluminum grades
  • Readily welded — 92/100, better than 95% of aluminum grades
  • Forms and bends easily — 87/100, better than 92% of aluminum grades
  • Polishes to a fine finish — 70/100, better than 87% of aluminum grades

Limitations

  • Low strength — 75 MPa (10.9 ksi), worse than 91% of aluminum grades
  • Difficult to machine — 32/100, worse than 89% of aluminum grades

1200-H22 properties

Typical room-temperature values for 1200-H22; 19 are specific to this condition. Other listed values are 1200 reference data and may not represent this condition. Bars are the position among aluminum grades.

Physical3

1200-H22 has a density of 2.71 g/cm³ (0.0979 lb/in³), heavier than 51% of aluminum grades. It melts at 645°C (1,193 °F).

Density2.71 g/cm³0.1 lb/in³
Melting Point (Solidus)645°C1,193 °F
Liquidus Temperature657°C1,215 °F

Mechanical10

1200-H22 has a yield strength of 75 MPa (10.9 ksi) and a tensile strength of 105 MPa (15.2 ksi) — weaker than 91% of aluminum grades. Elongation at break is 16% and the elastic modulus is 69 GPa (10 Msi).

Elastic (Young's) Modulus69 GPa10 Msi
Shear Modulus26 GPa3.8 Msi
Bulk Modulus70 GPa10.2 Msi
Poisson's Ratio0.33
Tensile Strength (Ultimate)105 MPa15.2 ksi
Yield Strength (0.2% offset)75 MPa10.9 ksi
Elongation at Break16%
Shear Strength66 MPa9.6 ksi
Fatigue Strength (Endurance Limit)40 MPa5.8 ksi
Hardness, Brinell28 HB

Thermal6

1200-H22 is rated for continuous service to 150°C (302 °F). It conducts heat at 228 W/m·K (131.7 BTU/hr·ft·°F), better than 95% of aluminum grades. Thermal expansion is 23.4 µm/m·K (13 µin/in·°F).

Thermal Conductivity228 W/m·K132 BTU/hr·ft·°F
Specific Heat Capacity900 J/kg·K0.21 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)23.4 µm/m·K13 µin/in·°F
Latent Heat of Fusion390 J/g168 BTU/lb
Max Service Temperature (continuous)150°C302 °F
Min Service Temperature-250°C-418 °F

Electrical3

1200-H22 conducts electricity at 58 % IACS, better than 95% of aluminum grades.

Electrical Conductivity58 % IACS
Electrical Resistivity2.97×10⁻⁸ Ω·m1.17 µΩ·in
Magnetic Responsenon-magnetic

Chemical & Environmental3

Corrosion resistance is very good (72/100), better than 83% of aluminum grades.

Galvanic Potential (seawater, vs SCE)-0.83 V
Corrosion ResistanceVery good72/100
Chemical Resistance SummaryExcellent in neutral water, atmosphere and many organics; resists concentrated nitric acid and sulphur compounds; attacked by strong alkalis, hydrochloric/hydrofluoric acids and by mercury; avoid direct contact with copper or steel in wet service.

Sustainability4

Producing a kilogram of 1200-H22 takes about 200 MJ of energy and emits 12 kg of CO₂ — less than 60% of aluminum grades. Typical recycled content is 20%.

Embodied Energy (primary production)200 MJ/kg85,985 BTU/lb
Embodied Carbon (primary production)12 kg CO₂/kg
Embodied Water1,200 L/kg144 gal/lb
Typical Recycled Content20%

Manufacturability8

1200-H22's machinability is poor (32/100, worse than 89% of aluminum grades); weldability excellent (92/100); formability excellent (87/100).

MachinabilityPoor32/100
Machinability Rating (AISI 1212 = 100 %)28%
WeldabilityExcellent92/100
Formability (cold)Excellent87/100
CastabilityPoor30/100
Brazeability / SolderabilityVery good80/100
PolishabilityVery good70/100
Anodizing Responseexcellent — bright clear and hard anodic films with high specular reflectivity; ideal for bright-anodized trim and reflectors

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with 1200-H22

Is 1200 easy to machine?

Very soft and gummy — use polished high-rake carbide, high speed, low feed pressure and flood lubricant to avoid built-up edge and tearing; not a choice for fine threads or tight tolerances.

Can 1200 be welded?

Excellent by TIG/MIG (1100 or 4043 filler) and resistance welding; welds return to near-O strength, so design joints for annealed properties.

Can 1200 be formed, bent or molded?

Outstanding cold formability in O/H111 — deep drawing, spinning, roll forming and foil rolling; anneal at ~345 °C between severe operations.

What surface finishes work on 1200?

Anodizes bright and clear (decorative and reflector work), takes conversion coatings and paint well after alkaline clean; mechanical polish is easy but soft and scratch-prone.

1200 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
SiSi + Fe combined max 1.00 %≤ 10.25
FeSi + Fe combined max 1.00 %≤ 10.5
Cu≤ 0.050.02
Mn≤ 0.050.02
Zn≤ 0.10.03
Ti≤ 0.050.02
Others (each)0.15 % total≤ 0.05—
Al≥ 99 (balance)—

1200-H22 — frequently asked

What is 1200-H22 used for?

1200-H22 is typically used for tank and vessel linings, architectural sheet and cladding, chemical process equipment liners, lighting reflectors, nameplates and signage and roofing, flashing and ducting sheet. In short: general-purpose pure; easy to form.

What is the yield strength of 1200-H22?

1200-H22 has a typical yield strength of 75 MPa (10.9 ksi) and a tensile strength of 105 MPa (15.2 ksi) — weaker than 91% of aluminum grades. Strength varies by condition: see the 13 listed tempers.

Is 1200-H22 easy to machine?

Not especially — machinability is rated poor (32/100, worse than 89% of aluminum grades). Very soft and gummy — use polished high-rake carbide, high speed, low feed pressure and flood lubricant to avoid built-up edge and tearing; not a choice for fine threads or tight tolerances.

Can 1200-H22 be welded?

Yes — weldability is rated excellent (92/100). Excellent by TIG/MIG (1100 or 4043 filler) and resistance welding; welds return to near-O strength, so design joints for annealed properties.

What surface finishes work on 1200-H22?

Anodizes bright and clear (decorative and reflector work), takes conversion coatings and paint well after alkaline clean; mechanical polish is easy but soft and scratch-prone.

Can 1200-H22 be formed, bent or molded?

Outstanding cold formability in O/H111 — deep drawing, spinning, roll forming and foil rolling; anneal at ~345 °C between severe operations.

What is the maximum service temperature of 1200-H22?

1200-H22 is rated for continuous use to about 150°C (302 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

Can FabDigit make parts in 1200-H22?

Yes — 1200-H22 is available for sheet metal; every part is priced by an engineer rather than instantly. Upload a STEP file to get a price and a DFM check.

Sources

  1. International Alloy Designations and Chemical Composition Limits for Wrought Aluminum (Teal Sheets) — The Aluminum Association (2018)
  2. EN 485-2 Aluminium and aluminium alloys — Sheet, strip and plate: mechanical properties — CEN (2016)
  3. ASTM B209 Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate — ASTM International (2021)
  4. ASM Handbook Vol. 2: Properties and Selection — Nonferrous Alloys — ASM International (1990)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.