FabDigit

Stainless Steel 2101 · heat-treated state · default condition

Stainless Steel 2101 Solution Annealed

Properties of the Solution Annealed condition, compared with the other 2101 tempers.

Default stocked condition for plate, coil, bar and tube — balanced 50/50 duplex structure with optimum corrosion resistance and toughness.

CNC machiningSheet metalPremium cost $$$

What is 2101 Solution Annealed?

2101 Solution Annealed is 2101 heat treated to Solution Annealed — default stocked condition for plate, coil, bar and tube — balanced 50/50 duplex structure with optimum corrosion resistance and toughness. 2101 Solution Annealed has a yield strength of 530 MPa (76.9 ksi) and a tensile strength of 750 MPa (109 ksi) — stronger than 81% of stainless steel grades. Elongation at break is 38% and the elastic modulus is 200 GPa (29 Msi). 2101 Solution Annealed has a density of 7.8 g/cm³ (0.282 lb/in³), heavier than 50% of stainless steel grades. It melts at 1,420°C (2,588 °F).

Advantages

  • Low embodied carbon — 3.5 kg CO₂/kg, better than 88% of stainless steel grades
  • High strength — 530 MPa (76.9 ksi), better than 81% of stainless steel grades
  • High electrical conductivity — 2.7 % IACS, better than 79% of stainless steel grades

Limitations

  • Limited service temperature — 300°C (572 °F), worse than 90% of stainless steel grades

2101 Solution Annealed properties

Typical room-temperature values for 2101 Solution Annealed — 12 properties are specific to this condition; the rest are grade-level values shared by every 2101 temper. Each bar shows where the value sits among the stainless steel grades in FabDigit's library — further right is higher.

Physical3

2101 Solution Annealed has a density of 7.8 g/cm³ (0.282 lb/in³), heavier than 50% of stainless steel grades. It melts at 1,420°C (2,588 °F).

Density7.8 g/cm³0.28 lb/in³
Melting Point (Solidus)1,420°C2,588 °F
Liquidus Temperature1,465°C2,669 °F

Mechanical16

2101 Solution Annealed has a yield strength of 530 MPa (76.9 ksi) and a tensile strength of 750 MPa (109 ksi) — stronger than 81% of stainless steel grades. Elongation at break is 38% and the elastic modulus is 200 GPa (29 Msi).

Elastic (Young's) Modulus200 GPa29 Msi
Shear Modulus77 GPa11.2 Msi
Bulk Modulus166 GPa24.1 Msi
Poisson's Ratio0.3
Tensile Strength (Ultimate)750 MPa109 ksi
Yield Strength (0.2% offset)530 MPa76.9 ksi
Elongation at Break38%
Reduction in Area55%
Compressive Strength530 MPa76.9 ksi
Shear Strength450 MPa65.3 ksi
Fatigue Strength (Endurance Limit)400 MPa58 ksi
Fracture Toughness (K_IC)120 MPa·√m109 ksi·√in
Charpy V-Notch Impact (RT)150 J111 ft·lbf
Hardness, Brinell230 HB
Hardness, Rockwell B98 HRB
Hardness, Vickers250 HV

Thermal6

2101 Solution Annealed is rated for continuous service to 300°C (572 °F). It conducts heat at 15 W/m·K (8.67 BTU/hr·ft·°F), worse than 59% of stainless steel grades. Thermal expansion is 13 µm/m·K (7.22 µin/in·°F).

Thermal Conductivity15 W/m·K8.7 BTU/hr·ft·°F
Specific Heat Capacity500 J/kg·K0.12 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)13 µm/m·K7.2 µin/in·°F
Latent Heat of Fusion270 J/g116 BTU/lb
Max Service Temperature (continuous)300°C572 °F
Min Service Temperature-50°C-58 °F

Electrical3

2101 Solution Annealed conducts electricity at 2.7 % IACS, better than 79% of stainless steel grades.

Electrical Conductivity2.7 % IACS
Electrical Resistivity6.5×10⁻⁷ Ω·m25.6 µΩ·in
Magnetic Responseferromagnetic

Chemical & Environmental3

Corrosion resistance is good (66/100), better than 58% of stainless steel grades.

Galvanic Potential (seawater, vs SCE)-0.1 V
Corrosion ResistanceGood66/100
Chemical Resistance SummaryBetter chloride pitting and far better chloride SCC resistance than 304/304L, roughly comparable to 316L in many waters; good in dilute sulphuric, organic acids, alkalis and abrasive slurries; not for hot concentrated halide acids, reducing acids (HCl) or service above ~300 °C.

Sustainability4

Producing a kilogram of 2101 Solution Annealed takes about 48 MJ of energy and emits 3.5 kg of CO₂ — less than 85% of stainless steel grades. Typical recycled content is 65%.

Embodied Energy (primary production)48 MJ/kg20,636 BTU/lb
Embodied Carbon (primary production)3.5 kg CO₂/kg
Embodied Water90 L/kg10.8 gal/lb
Typical Recycled Content65%

Manufacturability7

2101 Solution Annealed's machinability is fair (35/100, better than 51% of stainless steel grades); weldability very good (70/100); formability good (55/100).

MachinabilityFair35/100
Machinability Rating (AISI 1212 = 100 %)28%
WeldabilityVery good70/100
Formability (cold)Good55/100
Brazeability / SolderabilityFair40/100
PolishabilityVery good75/100
Anodizing Responsen/a — ferrous alloy; use pickling/passivation or electropolishing instead

Common Calculations5

Specific Strength (UTS / density)calculated96 kN·m/kg
Specific Stiffness (E / density)calculated25.6 MN·m/kg
Modulus of Resiliencecalculated702 kJ/m³
Thermal Diffusivitycalculated3.8 mm²/s
Thermal Shock Resistance Indexcalculated4

Values are nominal handbook figures for design screening. Certified mill or lot data ships with every FabDigit order on request.

Other 2101 tempers and conditions

2101 is also supplied in 5 other conditions. The full side-by-side table is on the 2101 overview.

Working with 2101 Solution Annealed

Is 2101 easy to machine?

Machine like a duplex: rigid setup, ~30–50 % of 304 cutting speed, heavy positive feed to cut under the work-hardened layer, sharp coated carbide and generous flood coolant.

Can 2101 be welded?

Weldable by GTAW/GMAW/SMAW/SAW with 2209 (22.9.3L) or 23.7.N filler, low-to-moderate heat input, interpass < 150 °C and no PWHT; avoid autogenous welding of thicker sections to keep ferrite/austenite balance.

Can 2101 be formed, bent or molded?

Cold formable but needs ~2× the press force and larger bend radii than 304, with noticeable springback; hot form 950–1150 °C then re-solution anneal and quench.

What surface finishes work on 2101?

Pickle and passivate after welding to restore the passive film; takes a good brushed or mirror polish, no anodizing (ferrous).

2101 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
C≤ 0.040.03
Si≤ 10.6
Mnaustenite stabiliser replacing Ni4 – 65
P≤ 0.04
Smax (0.015 max in EN 1.4162)≤ 0.03
Cr21 – 2221.5
Nilean-Ni1.35 – 1.71.5
Mo0.1 – 0.80.3
Cu0.1 – 0.80.3
Nkey strengthener / austenite stabiliser0.2 – 0.250.22
Febalance

2101 Solution Annealed — frequently asked

What is 2101 Solution Annealed used for?

2101 Solution Annealed is typically used for bridges, storage tanks and architectural cladding. In short: lean duplex stainless plate.

What is the yield strength of 2101 Solution Annealed?

2101 Solution Annealed has a typical yield strength of 530 MPa (76.9 ksi) and a tensile strength of 750 MPa (109 ksi) — stronger than 81% of stainless steel grades. Strength varies by condition: see the 6 listed tempers.

Is 2101 Solution Annealed easy to machine?

Not especially — machinability is rated fair (35/100, better than 51% of stainless steel grades). Machine like a duplex: rigid setup, ~30–50 % of 304 cutting speed, heavy positive feed to cut under the work-hardened layer, sharp coated carbide and generous flood coolant.

Can 2101 Solution Annealed be welded?

Yes — weldability is rated very good (70/100). Weldable by GTAW/GMAW/SMAW/SAW with 2209 (22.9.3L) or 23.7.N filler, low-to-moderate heat input, interpass < 150 °C and no PWHT; avoid autogenous welding of thicker sections to keep ferrite/austenite balance.

What surface finishes work on 2101 Solution Annealed?

Pickle and passivate after welding to restore the passive film; takes a good brushed or mirror polish, no anodizing (ferrous).

Can 2101 Solution Annealed be formed, bent or molded?

Cold formable but needs ~2× the press force and larger bend radii than 304, with noticeable springback; hot form 950–1150 °C then re-solution anneal and quench.

What is the maximum service temperature of 2101 Solution Annealed?

2101 Solution Annealed is rated for continuous use to about 300°C (572 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between 2101 Solution Annealed and 2101 1D?

Solution Annealed is the default condition — default stocked condition for plate, coil, bar and tube — balanced 50/50 duplex structure with optimum corrosion resistance and toughness. 1D: standard heavy plate condition (≈3–50 mm) for tanks, structures and abrasion-resistant liners. Yield strength is 530 MPa in Solution Annealed versus 500 MPa in 1D.

Can FabDigit make parts in 2101 Solution Annealed?

Yes — 2101 Solution Annealed is available for CNC machining and sheet metal with instant online pricing. Upload a STEP file to get a price and a DFM check.

Sources

  1. ASTM A240/A240M — Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip (S32101)ASTM International (2024)
  2. EN 10088-2 — Stainless steels: technical delivery conditions for sheet/plate and strip (1.4162)CEN (2014)
  3. Forta LDX 2101 / duplex stainless datasheetOutokumpu (2023)
  4. Sandvik SAF 2101 / lean duplex tube dataAlleima (Sandvik Materials Technology) (2022)
  5. ASM Specialty Handbook: Stainless SteelsASM International (1994)
  6. Practical Guidelines for the Fabrication of Duplex Stainless SteelsIMOA (2014)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.