FabDigitFabDigit

Copper Alloy C38000-H01

Supply condition

UNS C38000 · EN CW624N

H01 = quarter hard

Light draw pass on rod/bar for tighter tolerance, straightness and a modest strength increase.

Premium cost $$$

Values for the H01 condition

Other C38000 tempers and conditions

C38000 is listed in 5 conditions; see the grade overview at C38000.

Compare all 5 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
Soft annealed
Choose when maximum ductility is needed for bending, coining or upset heading of extruded stock.1253404578 HB27 % IACS
M30Default
As hot extruded
Standard stocking condition for architectural shapes, rod and bar — best combination of formability for hot bending and machinability.14041530100 HB27 % IACS
As hot rolled
Hot-worked plate, flat bar and forgings; slightly softer and more ductile than as-extruded product.1403803590 HB27 % IACS
H01This page
Quarter hard
Light draw pass on rod/bar for tighter tolerance, straightness and a modest strength increase.27545020130 HB26 % IACS
Half hard
Cold-drawn rod/bar for screw-machine parts and threaded fittings needing higher yield and better chip control.35049512150 HB26 % IACS

What is C38000-H01?

C38000-H01 is C38000 supplied in the H01 condition — light draw pass on rod/bar for tighter tolerance, straightness and a modest strength increase. C38000-H01 has a yield strength of 275 MPa (39.9 ksi) and a tensile strength of 450 MPa (65.3 ksi) — stronger than 57% of copper alloy grades. Elongation at break is 20% and the elastic modulus is 97 GPa (14.1 Msi). C38000-H01 has a density of 8.47 g/cm³ (0.306 lb/in³), lighter than 68% of copper alloy grades. It melts at 875°C (1,607 °F). M30 is the default condition FabDigit quotes; H01 is available on request or by drawing note.

Advantages

  • Easy to machine — 90/100, better than 98% of copper alloy grades

Limitations

  • Needs corrosion protection — 43/100, worse than 99% of copper alloy grades
  • Difficult to weld — 15/100, worse than 94% of copper alloy grades
  • Low stiffness — 97 GPa (14.1 Msi), worse than 88% of copper alloy grades

C38000-H01 properties

Typical room-temperature values for C38000-H01; 20 are specific to this condition. Other listed values are C38000 reference data and may not represent this condition. Bars are the position among copper alloy grades.

Physical3

C38000-H01 has a density of 8.47 g/cm³ (0.306 lb/in³), lighter than 68% of copper alloy grades. It melts at 875°C (1,607 °F).

Density8.47 g/cm³0.31 lb/in³
Melting Point (Solidus)875°C1,607 °F
Liquidus Temperature890°C1,634 °F

Mechanical13

C38000-H01 has a yield strength of 275 MPa (39.9 ksi) and a tensile strength of 450 MPa (65.3 ksi) — stronger than 57% of copper alloy grades. Elongation at break is 20% and the elastic modulus is 97 GPa (14.1 Msi).

Elastic (Young's) Modulus97 GPa14.1 Msi
Shear Modulus37 GPa5.4 Msi
Bulk Modulus110 GPa16 Msi
Poisson's Ratio0.34
Tensile Strength (Ultimate)450 MPa65.3 ksi
Yield Strength (0.2% offset)275 MPa39.9 ksi
Elongation at Break20%
Shear Strength290 MPa42.1 ksi
Fatigue Strength (Endurance Limit)150 MPa21.8 ksi
Charpy V-Notch Impact (RT)20 J14.8 ft·lbf
Hardness, Brinell130 HB
Hardness, Rockwell B75 HRB
Hardness, Vickers140 HV

Thermal6

C38000-H01 is rated for continuous service to 180°C (356 °F). It conducts heat at 121 W/m·K (69.9 BTU/hr·ft·°F), better than 68% of copper alloy grades. Thermal expansion is 20.9 µm/m·K (11.6 µin/in·°F).

Thermal Conductivity121 W/m·K69.9 BTU/hr·ft·°F
Specific Heat Capacity380 J/kg·K0.09 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)20.9 µm/m·K11.6 µin/in·°F
Latent Heat of Fusion165 J/g70.9 BTU/lb
Max Service Temperature (continuous)180°C356 °F
Min Service Temperature-200°C-328 °F

Electrical3

C38000-H01 conducts electricity at 26 % IACS, better than 63% of copper alloy grades.

Electrical Conductivity26 % IACS
Electrical Resistivity6.6×10⁻⁸ Ω·m2.6 µΩ·in
Magnetic Responsenon-magnetic

Chemical & Environmental3

Corrosion resistance is fair (43/100), worse than 99% of copper alloy grades.

Galvanic Potential (seawater, vs SCE)-0.25 V
Corrosion ResistanceFair43/100
Chemical Resistance SummaryGood in dry/marine atmospheres, fresh water and most neutral organics; attacked by ammonia and amines (season cracking), chlorides and acidic waters cause dezincification; not for oxidizing acids, sulfides or bright-water high-velocity service.

Sustainability4

Producing a kilogram of C38000-H01 takes about 55 MJ of energy and emits 3.5 kg of CO₂ — less than 72% of copper alloy grades. Typical recycled content is 75%.

Embodied Energy (primary production)55 MJ/kg23,646 BTU/lb
Embodied Carbon (primary production)3.5 kg CO₂/kg
Embodied Water300 L/kg35.9 gal/lb
Typical Recycled Content75%

Manufacturability7

C38000-H01's machinability is excellent (90/100, better than 98% of copper alloy grades); weldability poor (15/100); formability poor (20/100).

MachinabilityExcellent90/100
Machinability Rating (AISI 1212 = 100 %)90%
WeldabilityPoor15/100
Formability (cold)Poor20/100
Brazeability / SolderabilityVery good75/100
PolishabilityVery good82/100
Anodizing Responsen/a — copper alloy; use chemical/statuary patina, clear lacquer, or electroplated Cr/Ni finishes instead

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with C38000-H01

Is C38000 easy to machine?

Excellent free-cutting behaviour (≈90 % of C36000): use zero-to-negative rake carbide or HSS, high speeds, light feeds, and expect short broken chips; keep lead swarf segregated for recycling.

Can C38000 be welded?

Fusion welding is not recommended (lead-induced hot cracking and zinc fume); join by soldering, brazing with low-temperature silver filler, or mechanical fastening.

Can C38000 be formed, bent or molded?

Outstanding hot extrusion and hot bending at 650–750 °C; cold bending/heading is limited by the β phase — anneal or use O60 stock for tight radii.

What surface finishes work on C38000?

Takes a bright mechanical polish and statuary/oxidized patinas readily; protect with clear lacquer or wax outdoors, and Cr/Ni electroplating adheres well over a copper strike.

C38000 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
Cu55 – 6057
Pbfree-machining phase1.5 – 2.52
Alextrusion/strength addition≤ 0.50.3
Feimpurity limit≤ 0.35—
Snimpurity limit≤ 0.3—
Znremainder, ≈40 %balance—

C38000-H01 — frequently asked

What is C38000-H01 used for?

C38000-H01 is typically used for architectural extrusions, hardware and machined fittings. In short: top-machining extrusion brass; architectural section alloy; limited cold bending.

What is the yield strength of C38000-H01?

C38000-H01 has a typical yield strength of 275 MPa (39.9 ksi) and a tensile strength of 450 MPa (65.3 ksi) — stronger than 57% of copper alloy grades. Strength varies by condition: see the 5 listed tempers.

Is C38000-H01 easy to machine?

Yes — machinability is rated excellent (90/100, better than 98% of copper alloy grades). Excellent free-cutting behaviour (≈90 % of C36000): use zero-to-negative rake carbide or HSS, high speeds, light feeds, and expect short broken chips; keep lead swarf segregated for recycling.

Can C38000-H01 be welded?

Not readily — weldability is rated poor (15/100). Fusion welding is not recommended (lead-induced hot cracking and zinc fume); join by soldering, brazing with low-temperature silver filler, or mechanical fastening.

What surface finishes work on C38000-H01?

Takes a bright mechanical polish and statuary/oxidized patinas readily; protect with clear lacquer or wax outdoors, and Cr/Ni electroplating adheres well over a copper strike.

Can C38000-H01 be formed, bent or molded?

Outstanding hot extrusion and hot bending at 650–750 °C; cold bending/heading is limited by the β phase — anneal or use O60 stock for tight radii.

What is the maximum service temperature of C38000-H01?

C38000-H01 is rated for continuous use to about 180°C (356 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between C38000-M30 and C38000-H02?

M30 is the default condition — standard stocking condition for architectural shapes, rod and bar — best combination of formability for hot bending and machinability. H02: cold-drawn rod/bar for screw-machine parts and threaded fittings needing higher yield and better chip control. Yield strength is 140 MPa in M30 versus 350 MPa in H02.

Sources

  1. ASTM B455 — Copper-Zinc-Lead Alloy (Leaded Brass) Extruded Shapes — ASTM International (2020)
  2. ASTM B249 — General Requirements for Wrought Copper and Copper-Alloy Rod, Bar, Shapes and Forgings — ASTM International (2021)
  3. CDA Alloy Database — C38000 Architectural Bronze — Copper Development Association (2023)
  4. ASM Handbook Vol. 2 — Properties and Selection: Nonferrous Alloys — ASM International (1990)
  5. EN 12167 / EN 12164 — Copper and copper alloys, profiles and rods for general purposes — CEN (2016)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.