FabDigitFabDigit

Aluminum ER5654-H1X

Supply condition

ASTM AWS A5.10 ER5654 · EN S Al 5654A

Pick for spooled GMAW wire: cold-drawn temper gives the column strength and stiffness needed for trouble-free feeding of soft Al-Mg wire.

High cost $$$$

Values for the H1X condition

Other ER5654 tempers and conditions

ER5654 is listed in 3 conditions; see the grade overview at ER5654.

Compare all 3 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
AWDefault
As-welded deposit
Default condition for filler metals: properties of the as-deposited all-weld metal with no post-weld heat treatment.1152402058 HB33 % IACS
Annealed
Pick for TIG/GTAW cut lengths where soft, straight, easily hand-fed rod is wanted.1152402558 HB33 % IACS
H1XThis page
cold-drawn spooled MIG wire
Pick for spooled GMAW wire: cold-drawn temper gives the column strength and stiffness needed for trouble-free feeding of soft Al-Mg wire.255320885 HB32 % IACS

What is ER5654-H1X?

ER5654-H1X is ER5654 supplied in the H1X condition — pick for spooled GMAW wire: cold-drawn temper gives the column strength and stiffness needed for trouble-free feeding of soft Al-Mg wire. ER5654-H1X has a yield strength of 255 MPa (37 ksi) and a tensile strength of 320 MPa (46.4 ksi) — stronger than 67% of aluminum grades. Elongation at break is 8% and the elastic modulus is 70.3 GPa (10.2 Msi). ER5654-H1X has a density of 2.66 g/cm³ (0.0961 lb/in³), lighter than 84% of aluminum grades. It melts at 593°C (1,099 °F). AW is the default condition FabDigit quotes; H1X is available on request or by drawing note.

Advantages

  • Readily welded — 92/100, better than 95% of aluminum grades
  • Good corrosion resistance — 78/100, better than 94% of aluminum grades

Limitations

  • Limited service temperature — 65°C (149 °F), worse than 97% of aluminum grades

ER5654-H1X properties

Typical room-temperature values for ER5654-H1X; 20 are specific to this condition. Other listed values are ER5654 reference data and may not represent this condition. Bars are the position among aluminum grades.

Physical3

ER5654-H1X has a density of 2.66 g/cm³ (0.0961 lb/in³), lighter than 84% of aluminum grades. It melts at 593°C (1,099 °F).

Density2.66 g/cm³0.1 lb/in³
Melting Point (Solidus)593°C1,099 °F
Liquidus Temperature643°C1,189 °F

Mechanical10

ER5654-H1X has a yield strength of 255 MPa (37 ksi) and a tensile strength of 320 MPa (46.4 ksi) — stronger than 67% of aluminum grades. Elongation at break is 8% and the elastic modulus is 70.3 GPa (10.2 Msi).

Elastic (Young's) Modulus70.3 GPa10.2 Msi
Shear Modulus26.4 GPa3.8 Msi
Bulk Modulus68 GPa9.9 Msi
Poisson's Ratio0.33
Tensile Strength (Ultimate)320 MPa46.4 ksi
Yield Strength (0.2% offset)255 MPa37 ksi
Elongation at Break8%
Shear Strength185 MPa26.8 ksi
Fatigue Strength (Endurance Limit)140 MPa20.3 ksi
Hardness, Brinell85 HB

Thermal6

ER5654-H1X is rated for continuous service to 65°C (149 °F). It conducts heat at 125 W/m·K (72.2 BTU/hr·ft·°F), worse than 72% of aluminum grades. Thermal expansion is 23.9 µm/m·K (13.3 µin/in·°F).

Thermal Conductivity125 W/m·K72.2 BTU/hr·ft·°F
Specific Heat Capacity900 J/kg·K0.21 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)23.9 µm/m·K13.3 µin/in·°F
Latent Heat of Fusion390 J/g168 BTU/lb
Max Service Temperature (continuous)65°C149 °F
Min Service Temperature-196°C-321 °F

Electrical3

ER5654-H1X conducts electricity at 32 % IACS, worse than 63% of aluminum grades.

Electrical Conductivity32 % IACS
Electrical Resistivity5.39×10⁻⁸ Ω·m2.12 µΩ·in
Magnetic Responsenon-magnetic

Chemical & Environmental3

Corrosion resistance is very good (78/100), better than 94% of aluminum grades.

Galvanic Potential (seawater, vs SCE)-0.87 V
Corrosion ResistanceVery good78/100
Chemical Resistance SummaryExcellent in seawater, alkaline-free neutral waters and high-purity hydrogen peroxide (low Fe/Cu/Mn limits keep peroxide decomposition low); attacked by strong acids and strong caustics; avoid >65 °C sustained service to prevent Mg₂Al₃ grain-boundary sensitization and SCC.

Sustainability4

Producing a kilogram of ER5654-H1X takes about 200 MJ of energy and emits 12.5 kg of CO₂ — less than 60% of aluminum grades. Typical recycled content is 5%.

Embodied Energy (primary production)200 MJ/kg85,985 BTU/lb
Embodied Carbon (primary production)12.5 kg CO₂/kg
Embodied Water1,200 L/kg144 gal/lb
Typical Recycled Content5%

Manufacturability7

ER5654-H1X's machinability is fair (52/100, worse than 63% of aluminum grades); weldability excellent (92/100); formability fair (45/100).

MachinabilityFair52/100
Machinability Rating (AISI 1212 = 100 %)60%
WeldabilityExcellent92/100
Formability (cold)Fair45/100
Brazeability / SolderabilityPoor15/100
PolishabilityGood55/100
Anodizing Responsegood — clear/sulphuric anodize on the weld bead is uniform but slightly darker and greyer than 5652/5654 base metal; chemical-service tanks are normally left bare.

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with ER5654-H1X

Is ER5654 easy to machine?

Weld deposit is soft and gummy — use sharp polished high-rake carbide, high surface speed and generous lubrication to avoid built-up edge; dressing of peroxide-service welds should use clean, iron-free tooling.

Can ER5654 be welded?

Runs as GMAW spool wire or GTAW rod on 5652/5654/5154 (and other Mg-bearing 5000 series) with AC-TIG or spray-transfer pulsed MIG; keep interpass temperature low, use dedicated stainless brushes and Fe/Cu-free consumable handling to preserve purity, and avoid on Cu-bearing 2000-series alloys.

Can ER5654 be formed, bent or molded?

Supplied as cold-drawn spool wire or annealed cut lengths; straightening and re-coiling are routine, but avoid drawing lubricant residues that would contaminate high-purity joints.

What surface finishes work on ER5654?

Normally left bare and passivated/cleaned (nitric-acid or citric cleaning) for peroxide tanks; anodizes clear-to-grey if a decorative finish is required, and welds should be pickled rather than painted in chemical service.

ER5654 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
Mg3.1 – 3.93.5
Cr0.15 – 0.350.25
Tigrain refiner0.05 – 0.150.1
Si+Fecombined limit≤ 0.45—
Cu≤ 0.05—
Mnvery tight limit for peroxide service≤ 0.01—
Zn≤ 0.2—
Belimit applies where specified/older editions≤ 3×10⁻⁴—
Others (each)0.15 total≤ 0.05—
Albalance—

ER5654-H1X — frequently asked

What is ER5654-H1X used for?

ER5654-H1X is typically used for hydrogen peroxide tanks, high-purity chemical storage and semiconductor chemical delivery systems. In short: highest-purity Al-Mg filler; for peroxide and ultrapure tanks; best corrosion rating in family.

What is the yield strength of ER5654-H1X?

ER5654-H1X has a typical yield strength of 255 MPa (37 ksi) and a tensile strength of 320 MPa (46.4 ksi) — stronger than 67% of aluminum grades. Strength varies by condition: see the 3 listed tempers.

Is ER5654-H1X easy to machine?

Reasonably — machinability is rated fair (52/100, worse than 63% of aluminum grades). Weld deposit is soft and gummy — use sharp polished high-rake carbide, high surface speed and generous lubrication to avoid built-up edge; dressing of peroxide-service welds should use clean, iron-free tooling.

Can ER5654-H1X be welded?

Yes — weldability is rated excellent (92/100). Runs as GMAW spool wire or GTAW rod on 5652/5654/5154 (and other Mg-bearing 5000 series) with AC-TIG or spray-transfer pulsed MIG; keep interpass temperature low, use dedicated stainless brushes and Fe/Cu-free consumable handling to preserve purity, and avoid on Cu-bearing 2000-series alloys.

What surface finishes work on ER5654-H1X?

Normally left bare and passivated/cleaned (nitric-acid or citric cleaning) for peroxide tanks; anodizes clear-to-grey if a decorative finish is required, and welds should be pickled rather than painted in chemical service.

Can ER5654-H1X be formed, bent or molded?

Supplied as cold-drawn spool wire or annealed cut lengths; straightening and re-coiling are routine, but avoid drawing lubricant residues that would contaminate high-purity joints.

What is the maximum service temperature of ER5654-H1X?

ER5654-H1X is rated for continuous use to about 65°C (149 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between ER5654-AW and ER5654-H1X?

AW is the default condition — default condition for filler metals: properties of the as-deposited all-weld metal with no post-weld heat treatment. H1X: pick for spooled GMAW wire: cold-drawn temper gives the column strength and stiffness needed for trouble-free feeding of soft Al-Mg wire. Yield strength is 115 MPa in AW versus 255 MPa in H1X.

Sources

  1. AWS A5.10/A5.10M — Bare Aluminum and Aluminum-Alloy Welding Electrodes and Rods — AWS (2021)
  2. ISO 18273 — Welding consumables, wire electrodes/rods for aluminium and aluminium alloys (S Al 5654A) — ISO (2015)
  3. Teal Sheets — International Alloy Designations and Chemical Composition Limits for Wrought Aluminum — The Aluminum Association (2018)
  4. ASM Handbook Vol. 2 — Properties and Selection: Nonferrous Alloys (5154/5254/5654) — ASM International (1990)
  5. ASM Handbook Vol. 13B — Corrosion: Materials (aluminium alloys) — ASM International (2005)
  6. Aluminium filler metal selection and handling guides — ESAB / Lincoln Electric / Alcoa (2022)
  7. (ER5xxx) (2026)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.