FabDigitFabDigit

Titanium ZTC4 HIP+ANN

Heat-treated state

UNS R56406

HIP+ANN = hIP + Annealed

Aerospace/medical standard route: porosity closed and structure/stresses stabilised for best fatigue and toughness consistency.

High cost $$$$

Values for the HIP+ANN condition

Other ZTC4 tempers and conditions

ZTC4 is listed in 5 conditions; see the grade overview at ZTC4.

Compare all 5 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
As fabricated
Cheapest condition for non-critical corrosion or general engineering castings where GB/T 6614 minimum properties suffice.820890634 HRC—
AnnealedDefault
vacuum stress-relief/anneal ~700–800 °C, chemically milled
Standard commercial delivery condition for ZTC4 castings: residual stresses removed, alpha-case chem-milled, balanced strength/ductility.840910835 HRC—
HIP+ANNThis page
HIP + Annealed
Aerospace/medical standard route: porosity closed and structure/stresses stabilised for best fatigue and toughness consistency.8509251234 HRC—
Hot isostatic pressed
Pick when internal gas/shrink porosity must be closed for fatigue-critical or aerospace/medical castings.8559301135 HRC—
Solution treated and aged
Choose for maximum strength/hardness in thinner cast sections, accepting reduced ductility and toughness.9301,020638 HRC—

What is ZTC4 HIP+ANN?

ZTC4 HIP+ANN is ZTC4 heat treated to HIP+ANN — aerospace/medical standard route: porosity closed and structure/stresses stabilised for best fatigue and toughness consistency. ZTC4 HIP+ANN has a yield strength of 850 MPa (123 ksi) and a tensile strength of 925 MPa (134 ksi) — stronger than 66% of titanium grades. Elongation at break is 12% and the elastic modulus is 110 GPa (16 Msi). ZTC4 HIP+ANN has a density of 4.43 g/cm³ (0.16 lb/in³), lighter than 89% of titanium grades. It melts at 1,604°C (2,919 °F). Annealed is the default condition FabDigit quotes; HIP+ANN is available on request or by drawing note.

Advantages

  • Tough — resists crack growth — 85 MPa·√m (77.4 ksi·√in), better than 91% of titanium grades

Limitations

  • Limited formability — 10/100, worse than 99% of titanium grades
  • Low electrical conductivity — 1 % IACS, worse than 89% of titanium grades
  • Limited ductility — 12%, worse than 78% of titanium grades

ZTC4 HIP+ANN properties

Typical room-temperature values for ZTC4 HIP+ANN; 12 are specific to this condition. Other listed values are ZTC4 reference data and may not represent this condition. Bars are the position among titanium grades.

Physical3

ZTC4 HIP+ANN has a density of 4.43 g/cm³ (0.16 lb/in³), lighter than 89% of titanium grades. It melts at 1,604°C (2,919 °F).

Density4.43 g/cm³0.16 lb/in³
Melting Point (Solidus)1,604°C2,919 °F
Liquidus Temperature1,660°C3,020 °F

Mechanical16

ZTC4 HIP+ANN has a yield strength of 850 MPa (123 ksi) and a tensile strength of 925 MPa (134 ksi) — stronger than 66% of titanium grades. Elongation at break is 12% and the elastic modulus is 110 GPa (16 Msi).

Elastic (Young's) Modulus110 GPa16 Msi
Shear Modulus42 GPa6.1 Msi
Bulk Modulus110 GPa16 Msi
Poisson's Ratio0.34
Tensile Strength (Ultimate)925 MPa134 ksi
Yield Strength (0.2% offset)850 MPa123 ksi
Elongation at Break12%
Reduction in Area22%
Compressive Strength970 MPa141 ksi
Shear Strength580 MPa84.1 ksi
Fatigue Strength (Endurance Limit)500 MPa72.5 ksi
Fracture Toughness (K_IC)85 MPa·√m77.4 ksi·√in
Charpy V-Notch Impact (RT)20 J14.8 ft·lbf
Hardness, Brinell320 HB
Hardness, Rockwell C34 HRC
Hardness, Vickers335 HV

Thermal6

ZTC4 HIP+ANN is rated for continuous service to 350°C (662 °F). It conducts heat at 7 W/m·K (4.04 BTU/hr·ft·°F), worse than 76% of titanium grades. Thermal expansion is 8.8 µm/m·K (4.89 µin/in·°F).

Thermal Conductivity7 W/m·K4 BTU/hr·ft·°F
Specific Heat Capacity560 J/kg·K0.13 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)8.8 µm/m·K4.9 µin/in·°F
Latent Heat of Fusion365 J/g157 BTU/lb
Max Service Temperature (continuous)350°C662 °F
Min Service Temperature-253°C-423 °F

Electrical3

ZTC4 HIP+ANN conducts electricity at 1 % IACS, worse than 89% of titanium grades.

Electrical Conductivity1 % IACS
Electrical Resistivity1.71×10⁻⁶ Ω·m67.3 µΩ·in
Magnetic Responsenon-magnetic

Chemical & Environmental3

Corrosion resistance is excellent (88/100), worse than 77% of titanium grades.

Galvanic Potential (seawater, vs SCE)-0.12 V
Corrosion ResistanceExcellent88/100
Chemical Resistance SummaryPassive and essentially immune to seawater, chlorides, wet chlorine, nitric acid and most oxidising media; attacked by HF, hot concentrated HCl/H2SO4/phosphoric acid, dry chlorine and hot fluoride solutions; absorbs hydrogen and oxygen above ~500 °C in air.

Sustainability4

Producing a kilogram of ZTC4 HIP+ANN takes about 700 MJ of energy and emits 45 kg of CO₂ — more than 74% of titanium grades. Typical recycled content is 25%.

Embodied Energy (primary production)700 MJ/kg300,946 BTU/lb
Embodied Carbon (primary production)45 kg CO₂/kg
Embodied Water600 L/kg71.9 gal/lb
Typical Recycled Content25%

Manufacturability8

ZTC4 HIP+ANN's machinability is poor (19/100, worse than 78% of titanium grades); weldability very good (75/100); formability not recommended (10/100).

MachinabilityPoor19/100
Machinability Rating (AISI 1212 = 100 %)20%
WeldabilityVery good75/100
Formability (cold)Not recommended10/100
CastabilityGood68/100
Brazeability / SolderabilityFair40/100
PolishabilityVery good70/100
Anodizing Responsegood — Ti anodising per AMS 2488 Type II for galling resistance, or colour interference anodising; not a hard-coat like aluminium and no dimensional build-up

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with ZTC4 HIP+ANN

Is ZTC4 easy to machine?

Machine like wrought Ti-6Al-4V but remove the hard alpha-case/reaction layer first (chem-mill) — low surface speed (~25–45 m/min carbide), heavy positive-rake sharp tools, high-pressure flood coolant, never dwell in cut.

Can ZTC4 be welded?

GTAW/EBW/plasma weld repair with ERTi-5 filler is routine and standard for castings, but must be done in high-purity argon chambers or vacuum with clean, hydride-free surfaces followed by stress-relief anneal.

Can ZTC4 be formed, bent or molded?

Vacuum-arc-melted metal poured into ceramic-shell investment or rammed-graphite moulds; needs ~1.5–2 % pattern shrink allowance, generous fillets, and HIP for porosity-sensitive parts.

What surface finishes work on ZTC4?

Grit-blast plus HF/HNO3 chemical milling to strip alpha-case; then optional Type II anodise (AMS 2488) for galling resistance, passivation, or mechanical/electro-polish; avoid Cd/Cl-bearing marking and cleaning agents.

ZTC4 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
Alalpha stabiliser5.5 – 6.756.1
Vbeta stabiliser3.5 – 4.54
Fe≤ 0.30.12
Si≤ 0.150.05
C≤ 0.10.03
N≤ 0.050.02
H≤ 0.020.01
Ohigher than wrought TC4; controls strength/ductility≤ 0.20.14
Other, each≤ 0.1—
Other, total≤ 0.4—
Tibalance—

ZTC4 HIP+ANN — frequently asked

What is ZTC4 HIP+ANN used for?

ZTC4 HIP+ANN is typically used for aerospace structural castings, pump/valve bodies, impellers and biomedical implant castings. In short: workhorse cast Ti-6Al-4V; high strength, low machinability; wide foundry availability.

What is the yield strength of ZTC4 HIP+ANN?

ZTC4 HIP+ANN has a typical yield strength of 850 MPa (123 ksi) and a tensile strength of 925 MPa (134 ksi) — stronger than 66% of titanium grades. Strength varies by condition: see the 5 listed tempers.

Is ZTC4 HIP+ANN easy to machine?

Not especially — machinability is rated poor (19/100, worse than 78% of titanium grades). Machine like wrought Ti-6Al-4V but remove the hard alpha-case/reaction layer first (chem-mill) — low surface speed (~25–45 m/min carbide), heavy positive-rake sharp tools, high-pressure flood coolant, never dwell in cut.

Can ZTC4 HIP+ANN be welded?

Yes — weldability is rated very good (75/100). GTAW/EBW/plasma weld repair with ERTi-5 filler is routine and standard for castings, but must be done in high-purity argon chambers or vacuum with clean, hydride-free surfaces followed by stress-relief anneal.

What surface finishes work on ZTC4 HIP+ANN?

Grit-blast plus HF/HNO3 chemical milling to strip alpha-case; then optional Type II anodise (AMS 2488) for galling resistance, passivation, or mechanical/electro-polish; avoid Cd/Cl-bearing marking and cleaning agents.

Can ZTC4 HIP+ANN be formed, bent or molded?

Vacuum-arc-melted metal poured into ceramic-shell investment or rammed-graphite moulds; needs ~1.5–2 % pattern shrink allowance, generous fillets, and HIP for porosity-sensitive parts.

What is the maximum service temperature of ZTC4 HIP+ANN?

ZTC4 HIP+ANN is rated for continuous use to about 350°C (662 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between ZTC4 Annealed and ZTC4-STA?

Annealed is the default condition — standard commercial delivery condition for ZTC4 castings: residual stresses removed, alpha-case chem-milled, balanced strength/ductility. STA: choose for maximum strength/hardness in thinner cast sections, accepting reduced ductility and toughness. Yield strength is 840 MPa in Annealed versus 930 MPa in STA.

Sources

  1. ASTM B367 Standard Specification for Titanium and Titanium Alloy Castings (Grade C-5 / R56406) — ASTM International (2022)
  2. ASM Specialty Handbook: Titanium and Titanium Alloys — ASM International (1994)
  3. ASM Handbook Vol. 2 — Properties and Selection: Nonferrous Alloys — ASM International (1990)
  4. ASM Handbook Vol. 13B — Corrosion: Materials (titanium) — ASM International (2005)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.