Solder & Low-Melting Alloy Pb-Ca-Sn Battery Grid Alloy

Pb-Ca-Sn Battery Grid Alloy is a low-antimony to antimony-free lead alloy strengthened by small calcium and tin additions and by ageing, and it is the standard grid alloy for maintenance-free lead-acid batteries.

Standard cost $$

Reference datasheet — Pb-Ca-Sn Battery Grid Alloy is not in the instant-quote catalog. Upload your part and an engineer will quote it in this grade or suggest the closest stocked equivalent.

Values for the CAST-AGED condition

Pb-Ca-Sn Battery Grid Alloy tempers and conditions

Pb-Ca-Sn Battery Grid Alloy is supplied in 7 conditions, soft to hard. CAST-AGED is the default FabDigit quotes; the values on this page are for it.

Compare all 7 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
As fabricated
Freshly gravity-cast grids straight off the machine — soft and easily damaged; strength develops only after ageing.2038259 HB6.4 % IACS
Low-tin negative-grid composition (≈0.2–0.4 % Sn, aged)
Cheapest variant for negative grids where tin is not needed to keep the corrosion layer conductive.30451515 HB7.4 % IACS
Rolled strip, as-rolled
Cast slab rolled to grid strip; ductile immediately after rolling, used when grids are expanded straight from the mill.32523014 HB6.8 % IACS
CAST-AGEDDefault
Cast + age hardened (natural or 60–100 °C artificial ageing)
The standard supplied condition for gravity-cast SLI and stationary grids: aged to stable Ca/Sn precipitation strength before pasting.35551218 HB6.8 % IACS
High-tin positive-grid composition (≈0.8–1.5 % Sn, aged)
Tin-rich version for positive grids — suppresses the passivating barrier layer (PCL-1) and improves mould filling of thin grids.42621021 HB6.2 % IACS
Silver-bearing variant (0.01–0.04 % Ag, aged)
Silver micro-addition for deep-cycle and high-temperature (under-hood, telecom) positive grids — better creep and grid-growth resistance.46661222 HB6.1 % IACS
Rolled strip + age hardened
Highest-strength commercial condition — rolled wrought structure plus Ca/Sn precipitation; best creep and grid-growth resistance.50722224 HB6.8 % IACS

Supply forms, finishes and certifications

Ways Pb-Ca-Sn Battery Grid Alloy is supplied — form, process route, surface or paperwork — without a datasheet of their own. The property values above apply.

OptionWhat it isType
CC
Continuous cast stripSurface finish
Expanded
Expanded-metal gridSurface finish
Punched
Punched strip gridSurface finish

What is Pb-Ca-Sn Battery Grid Alloy?

Pb-Ca-Sn Battery Grid Alloy is a low-antimony to antimony-free lead alloy strengthened by small calcium and tin additions and by ageing, and it is the standard grid alloy for maintenance-free lead-acid batteries. It is produced as book-mould castings, continuous-cast and rolled strip, and expanded or punched grids, including low-Sn negative, high-Sn positive and Pb-Ca-Sn-Ag variants, with 55 MPa tensile, 35 MPa yield, 12% elongation and 18 HB. Service is limited to about 80 °C, and calcium burns off during remelting and overheated welding. Antimonial lead remains the alternative where the antimony-free chemistry is not required. Pb-Ca-Sn Battery Grid Alloy has a density of 11.28 g/cm³ (0.408 lb/in³), heavier than 94% of solder & low-melting alloy grades. It melts at 318°C (604 °F). Pb-Ca-Sn Battery Grid Alloy has a yield strength of 35 MPa (5.08 ksi) and a tensile strength of 55 MPa (7.98 ksi) — stronger than 81% of solder & low-melting alloy grades. Elongation at break is 12% and the elastic modulus is 16 GPa (2.32 Msi).

What is Pb-Ca-Sn Battery Grid Alloy used for?

  • Maintenance-free battery grids
  • VRLA battery plates
  • Continuous-cast grid strip
  • Expanded-metal negative grids
  • Punched positive grids
  • Cast-on-strap battery connectors
  • Battery terminal posts

Advantages

  • Low embodied carbon — 1.8 kg CO₂/kg, better than 98% of solder & low-melting alloy grades
  • Readily welded — 60/100, better than 92% of solder & low-melting alloy grades
  • High strength — 35 MPa (5.08 ksi), better than 81% of solder & low-melting alloy grades
  • Good corrosion resistance — 55/100, better than 78% of solder & low-melting alloy grades

Limitations

  • Heavy — 11.28 g/cm³ (0.408 lb/in³), worse than 94% of solder & low-melting alloy grades
  • Low stiffness — 16 GPa (2.32 Msi), worse than 88% of solder & low-melting alloy grades
  • Limited service temperature — 80°C (176 °F), worse than 88% of solder & low-melting alloy grades
  • Hard to polish — 20/100, worse than 88% of solder & low-melting alloy grades
  • Limited ductility — 12%, worse than 83% of solder & low-melting alloy grades

Pb-Ca-Sn Battery Grid Alloy properties

Typical room-temperature values for Pb-Ca-Sn Battery Grid Alloy-CAST-AGED; bars are the position among solder & low-melting alloy grades.

Physical3

Pb-Ca-Sn Battery Grid Alloy has a density of 11.28 g/cm³ (0.408 lb/in³), heavier than 94% of solder & low-melting alloy grades. It melts at 318°C (604 °F).

Density11.28 g/cm³0.41 lb/in³
Melting Point (Solidus)318°C604 °F
Liquidus Temperature327°C621 °F

Mechanical13

Pb-Ca-Sn Battery Grid Alloy has a yield strength of 35 MPa (5.08 ksi) and a tensile strength of 55 MPa (7.98 ksi) — stronger than 81% of solder & low-melting alloy grades. Elongation at break is 12% and the elastic modulus is 16 GPa (2.32 Msi).

Elastic (Young's) Modulus16 GPa2.3 Msi
Shear Modulus5.6 GPa0.81 Msi
Bulk Modulus45 GPa6.5 Msi
Poisson's Ratio0.44
Tensile Strength (Ultimate)55 MPa8 ksi
Yield Strength (0.2% offset)35 MPa5.1 ksi
Elongation at Break12%
Reduction in Area25%
Compressive Strength50 MPa7.3 ksi
Shear Strength35 MPa5.1 ksi
Fatigue Strength (Endurance Limit)12 MPa1.7 ksi
Hardness, Brinell18 HB
Hardness, Vickers19 HV

Thermal6

Pb-Ca-Sn Battery Grid Alloy is rated for continuous service to 80°C (176 °F). It conducts heat at 33 W/m·K (19.1 BTU/hr·ft·°F), worse than 76% of solder & low-melting alloy grades. Thermal expansion is 29 µm/m·K (16.1 µin/in·°F).

Thermal Conductivity33 W/m·K19.1 BTU/hr·ft·°F
Specific Heat Capacity130 J/kg·K0.03 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)29 µm/m·K16.1 µin/in·°F
Latent Heat of Fusion23 J/g9.9 BTU/lb
Max Service Temperature (continuous)80°C176 °F
Min Service Temperature-40°C-40 °F

Electrical3

Pb-Ca-Sn Battery Grid Alloy conducts electricity at 6.8 % IACS, worse than 80% of solder & low-melting alloy grades.

Electrical Conductivity6.8 % IACS
Electrical Resistivity2.5×10⁻⁷ Ω·m9.84 µΩ·in
Magnetic Responsenon-magnetic

Chemical & Environmental3

Corrosion resistance is good (55/100), better than 78% of solder & low-melting alloy grades.

Galvanic Potential (seawater, vs SCE)-0.55 V
Corrosion ResistanceGood55/100
Chemical Resistance SummaryOutstanding in sulfuric acid (protective PbSO4/PbO2 film) and in most sulfates and phosphoric acid; attacked by nitric, acetic and other organic acids, nitrates, and by soft/distilled water; toxic — restricted for potable-water and food contact.

Sustainability4

Producing a kilogram of Pb-Ca-Sn Battery Grid Alloy takes about 22 MJ of energy and emits 1.8 kg of CO₂ — less than 98% of solder & low-melting alloy grades. Typical recycled content is 85%.

Embodied Energy (primary production)22 MJ/kg9,458 BTU/lb
Embodied Carbon (primary production)1.8 kg CO₂/kg
Embodied Water180 L/kg21.6 gal/lb
Typical Recycled Content85%

Manufacturability8

Pb-Ca-Sn Battery Grid Alloy's machinability is fair (45/100, better than 69% of solder & low-melting alloy grades); weldability good (60/100); formability excellent (85/100).

MachinabilityFair45/100
Machinability Rating (AISI 1212 = 100 %)55%
WeldabilityGood60/100
Formability (cold)Excellent85/100
CastabilityExcellent85/100
Brazeability / SolderabilityExcellent90/100
PolishabilityPoor20/100
Anodizing Responsen/a — not an anodizable metal; surface protection is the in-service PbSO4/PbO2 film

Common Calculations5

Specific Strength (UTS / density)calculated5 kN·m/kg
Specific Stiffness (E / density)calculated1.4 MN·m/kg
Modulus of Resiliencecalculated38 kJ/m³
Thermal Diffusivitycalculated22.5 mm²/s
Thermal Shock Resistance Indexcalculated4

Values are nominal handbook figures for design screening. Certified mill or lot data ships with every FabDigit order on request.

Strength versus weight in the solder & low-melting alloy family

Yield strength against density for every solder & low-melting alloy grade FabDigit runs. Pb-Ca-Sn Battery Grid Alloy is highlighted; hover a dot for its name, or open the interactive family chart.

125102050891011Density (g/cm³)Yield strength (MPa) — log scalePb-Ca-Sn Battery Grid Alloy

Working with Pb-Ca-Sn Battery Grid Alloy

Is Pb-Ca-Sn Battery Grid Alloy easy to machine?

Machines very easily but smears and loads tools — use sharp positive-rake tooling, high speed, light cuts, and full lead-dust/fume containment.

Can Pb-Ca-Sn Battery Grid Alloy be welded?

Joined by lead burning (oxy-fuel or TIG with matching Pb-Sn filler) and by cast-on-strap; avoid excessive heat which burns off calcium.

Can Pb-Ca-Sn Battery Grid Alloy be formed, bent or molded?

Book-mould gravity casting, drum/belt continuous casting, or rolling to strip followed by expanding or punching; grids must be aged before pasting to avoid handling damage.

Pb-Ca-Sn Battery Grid Alloy chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
Caage-hardening addition; ~0.06–0.08 % typical for positive grids0.06 – 0.120.09
Snlow end for negative grids, 0.8–1.5 % for positive/expanded grids0.3 – 1.50.8
Almelt-surface protection against Ca oxidation loss0.01 – 0.030.02
Agoptional, creep/high-temperature variant only0 – 0.040
Sbimpurity limit — antimony causes gassing/water loss≤ 0
Biimpurity limit≤ 0.03
Feimpurity limit≤ 0
Cuimpurity limit≤ 0.01
Pbbalance

What surface finishes work on Pb-Ca-Sn Battery Grid Alloy?

No plating or anodizing — service protection is the electrochemically formed PbSO4/PbO2 layer; keep surfaces oxide-free before pasting and strap welding.

Equivalent designations

Standards and trade names that resolve to Solder & Low-Melting Alloy Pb-Ca-Sn Battery Grid Alloy in FabDigit's catalog. Equivalence is nominal — check the exact specification when certification matters.

Also called
Pb-Ca-Sn

How much does Pb-Ca-Sn Battery Grid Alloy cost?

Pb-Ca-Sn Battery Grid Alloy is a standard-cost solder & low-melting alloy ($$), cheaper than about 71% of the materials FabDigit quotes. Part price depends far more on geometry, tolerance and quantity than on the raw stock — upload a CAD file for a live quote.

Pb-Ca-Sn Battery Grid Alloy — frequently asked

What is Pb-Ca-Sn Battery Grid Alloy used for?

Pb-Ca-Sn Battery Grid Alloy is typically used for maintenance-free battery grids, VRLA battery plates, continuous-cast grid strip, expanded-metal negative grids, punched positive grids and cast-on-strap battery connectors. In short: antimony-free grid alloy; age-hardening lead alloy; standard for maintenance-free batteries.

What is the yield strength of Pb-Ca-Sn Battery Grid Alloy?

Pb-Ca-Sn Battery Grid Alloy has a typical yield strength of 35 MPa (5.08 ksi) and a tensile strength of 55 MPa (7.98 ksi) — stronger than 81% of solder & low-melting alloy grades. Strength varies by condition: see the 7 listed tempers.

Is Pb-Ca-Sn Battery Grid Alloy easy to machine?

Reasonably — machinability is rated fair (45/100, better than 69% of solder & low-melting alloy grades). Machines very easily but smears and loads tools — use sharp positive-rake tooling, high speed, light cuts, and full lead-dust/fume containment.

Can Pb-Ca-Sn Battery Grid Alloy be welded?

Yes — weldability is rated good (60/100). Joined by lead burning (oxy-fuel or TIG with matching Pb-Sn filler) and by cast-on-strap; avoid excessive heat which burns off calcium.

What surface finishes work on Pb-Ca-Sn Battery Grid Alloy?

No plating or anodizing — service protection is the electrochemically formed PbSO4/PbO2 layer; keep surfaces oxide-free before pasting and strap welding.

Can Pb-Ca-Sn Battery Grid Alloy be formed, bent or molded?

Book-mould gravity casting, drum/belt continuous casting, or rolling to strip followed by expanding or punching; grids must be aged before pasting to avoid handling damage.

What is the maximum service temperature of Pb-Ca-Sn Battery Grid Alloy?

Pb-Ca-Sn Battery Grid Alloy is rated for continuous use to about 80°C (176 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between Pb-Ca-Sn Battery Grid Alloy CAST-AGED and Pb-Ca-Sn Battery Grid Alloy-F?

CAST-AGED is the default condition — the standard supplied condition for gravity-cast SLI and stationary grids: aged to stable Ca/Sn precipitation strength before pasting. F: freshly gravity-cast grids straight off the machine — soft and easily damaged; strength develops only after ageing. Yield strength is 35 MPa in CAST-AGED versus 20 MPa in F.

How much does Pb-Ca-Sn Battery Grid Alloy cost?

Pb-Ca-Sn Battery Grid Alloy is a standard-cost solder & low-melting alloy ($$), cheaper than about 71% of the materials FabDigit quotes. Part price depends far more on geometry, tolerance and quantity than on the raw stock — upload a CAD file for a live quote.

Sources

  1. ASTM B29 — Refined Lead — ASTM International (2020)
  2. GB/T 469 (2018)
  3. ASM Handbook Vol. 2 — Properties and Selection: Nonferrous Alloys (Lead and Lead Alloys) — ASM International (1990)
  4. Lead-Acid Batteries: Science and Technology (grid alloy chapters) — Elsevier (2011)
  5. Lead grid alloy ingot and strip datasheets (secondary lead smelters) — various (2023)

Property data is compiled from published supplier and standards handbooks and normalised for comparison; hardness values on non-Brinell scales are converted approximately for charting only. Manufacturability limits are FabDigit quote-engine defaults and may be relaxed by engineering review. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.