FabDigitFabDigit

PLLA TALC20

Reinforced grade

TALC20 = 20% talc / mineral-filled PLLA

Cost-down, faster-crystallizing compound for rigid packaging and thermoformed trays with improved heat resistance.

Premium cost $$$

Values for the TALC20 condition

Other PLLA grades and fills

PLLA is listed in 8 conditions; see the grade overview at PLLA.

Compare all 8 grades and fillsHide
Grade · open for datasheetBest forYield MPaTensile MPaElong. %Hardness
Foamed / expanded PLLA
Physically blown biobased foam for protective packaging and insulation where low density matters more than strength.—0.68—
Impact-modified / toughened PLLA
Core-shell or bio-elastomer toughened compound for drop-resistant housings and durable goods, at the cost of stiffness and clarity.424512072 Shore D
Flame-retardant PLLA
Phosphorus/nitrogen FR compound for electronics housings and appliance parts that must meet UL 94 V-0.44452.582 Shore D
TALC20This page
20% talc / mineral-filled PLLA
Cost-down, faster-crystallizing compound for rigid packaging and thermoformed trays with improved heat resistance.47482.585 Shore D
Nucleated fast-crystallizing PLLA
Pick for injection moulding with short cycles when a crystalline, heat-resistant part is needed straight out of the tool.5860384 Shore D
Annealed / crystallized PLLA
Choose when the part must survive hot-fill, dishwasher or ~90–110 °C air service: crystallinity is developed by hot mold or post-mold annealing.—683—
Stereocomplex PLLA/PDLA blend
Blend with PDLA to form the stereocomplex crystal — melting point jumps to ~220–230 °C for the highest heat resistance available from PLA chemistry.6870585 Shore D
30% glass-fiber reinforced PLLA
For structural biobased parts needing high stiffness and dimensional stability; must be moulded hot/annealed to exploit the heat resistance.—1002—

What is PLLA TALC20?

PLLA TALC20 is PLLA in the TALC20 grade — cost-down, faster-crystallizing compound for rigid packaging and thermoformed trays with improved heat resistance. PLLA TALC20 has a yield strength of 47 MPa (6.82 ksi) and a tensile strength of 48 MPa (6.96 ksi) — weaker than 55% of polymer grades. Elongation at break is 2.5% and the elastic modulus is 4.8 GPa (0.696 Msi). PLLA TALC20 has a density of 1.38 g/cm³ (0.0499 lb/in³), heavier than 77% of polymer grades. Its glass-transition temperature is 61°C (142 °F).

Advantages

  • Low embodied carbon — 1.3 kg CO₂/kg, better than 100% of polymer grades
  • Stiff — 4.8 GPa (0.696 Msi), better than 88% of polymer grades
  • Polishes to a fine finish — 70/100, better than 77% of polymer grades

Limitations

  • Needs corrosion protection — 55/100, worse than 94% of polymer grades
  • Limited ductility — 2.5%, worse than 89% of polymer grades
  • Limited service temperature — 60°C (140 °F), worse than 87% of polymer grades
  • Heavy — 1.38 g/cm³ (0.0499 lb/in³), worse than 77% of polymer grades
  • Limited formability — 18/100, worse than 76% of polymer grades

PLLA TALC20 properties

Typical room-temperature values for PLLA TALC20; 27 are specific to this condition. Other listed values are PLLA reference data and may not represent this condition. Bars are the position among polymer grades.

Physical7

PLLA TALC20 has a density of 1.38 g/cm³ (0.0499 lb/in³), heavier than 77% of polymer grades. Its glass-transition temperature is 61°C (142 °F).

Density1.38 g/cm³0.05 lb/in³
Melting Temperature (Tm)175°C347 °F
Glass Transition (Tg)61°C142 °F
Water Absorption (24 h)0.4%
Water Absorption (Saturation)1%
Refractive Index1.46
Light Transmission5%

Mechanical15

PLLA TALC20 has a yield strength of 47 MPa (6.82 ksi) and a tensile strength of 48 MPa (6.96 ksi) — weaker than 55% of polymer grades. Elongation at break is 2.5% and the elastic modulus is 4.8 GPa (0.696 Msi).

Elastic (Young's) Modulus4.8 GPa0.7 Msi
Shear Modulus1.3 GPa0.19 Msi
Bulk Modulus4 GPa0.59 Msi
Poisson's Ratio0.36
Tensile Strength (Ultimate)48 MPa7 ksi
Yield Strength (0.2% offset)47 MPa6.8 ksi
Elongation at Break2.5%
Compressive Strength95 MPa13.8 ksi
Compressive Modulus3.3 GPa0.48 Msi
Flexural Strength75 MPa10.9 ksi
Flexural Modulus5 GPa0.73 Msi
Fracture Toughness (K_IC)2.6 MPa·√m2.4 ksi·√in
Izod Impact, Notched20 J/m0.37 ft·lbf/in
Hardness, Shore D85 Shore D
Hardness, Rockwell R95 HRR

Thermal11

PLLA TALC20 is rated for continuous service to 60°C (140 °F). It conducts heat at 0.25 W/m·K (0.144 BTU/hr·ft·°F), better than 72% of polymer grades. Thermal expansion is 75 µm/m·K (41.7 µin/in·°F).

Thermal Conductivity0.25 W/m·K0.14 BTU/hr·ft·°F
Specific Heat Capacity1,500 J/kg·K0.36 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)75 µm/m·K41.7 µin/in·°F
Max Service Temperature (continuous)60°C140 °F
Min Service Temperature-20°C-4 °F
Heat Deflection Temp. @ 0.45 MPa105°C221 °F
Heat Deflection Temp. @ 1.8 MPa58°C136 °F
Vicat Softening Point (B50)61°C142 °F
Flammability (UL 94)HB (typically ~1.5 mm); no self-extinguishing rating without FR package
Limiting Oxygen Index22%
Max Service Temperature (short-term)80°C176 °F

Electrical6

PLLA TALC20 is an electrical insulator with a dielectric strength of 18 kV/mm (457.2 V/mil) and a resistivity of 1×10¹⁴ Ω·m.

Electrical Resistivity1×10¹⁴ Ω·m3.94×10²¹ µΩ·in
Dielectric Strength18 kV/mm457 V/mil
Dielectric Constant (1 MHz)3
Dissipation Factor (1 MHz)0.015
Volume Resistivity1×10¹⁶ Ω·cm
Surface Resistivity1×10¹⁶ Ω

Chemical & Environmental3

Corrosion resistance is good (55/100), worse than 94% of polymer grades. UV resistance is fair.

Corrosion ResistanceGood55/100
UV / Weathering ResistanceFair45/100
Chemical Resistance SummaryGood against aliphatic hydrocarbons, oils, greases and most foods; attacked by chlorinated solvents, acetone, THF, chloroform and dioxane (solvents); hydrolyses steadily in hot water, steam, acids and especially alkalis — not for sustained wet service above Tg.

Sustainability3

Producing a kilogram of PLLA TALC20 takes about 50 MJ of energy and emits 1.3 kg of CO₂ — less than 99% of polymer grades. Typical recycled content is 0%.

Embodied Energy (primary production)50 MJ/kg21,496 BTU/lb
Embodied Carbon (primary production)1.3 kg CO₂/kg
Typical Recycled Content0%

Manufacturability8

PLLA TALC20's machinability is good (55/100, worse than 64% of polymer grades); weldability good (60/100); formability poor (18/100).

MachinabilityGood55/100
WeldabilityGood60/100
Formability (cold)Poor18/100
PolishabilityVery good70/100
Mold Shrinkage0.6%
Melt Flow Rate10 g/10 min
Processing Melt Temperature (typ.)205°C401 °F
Mold Temperature (typ.)30°C86 °F

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with PLLA TALC20

Is PLLA easy to machine?

Machines like acrylic with sharp, high-rake tools and air blast — keep speeds moderate and avoid coolant soak, since frictional heat above 60 °C softens the part and hot water accelerates hydrolysis.

Can PLLA be welded?

Ultrasonic, hot-plate, vibration and laser welding all work well; solvent bonding with chloroform/dichloromethane or cyanoacrylate gives strong joints on non-crystalline surfaces.

Can PLLA be formed, bent or molded?

Dry to <250 ppm (4 h at 80 °C, or 45 °C for high-IV medical resin) before processing to prevent hydrolytic molecular-weight loss; mould at 190–220 °C melt with a cold tool (20–30 °C) for clear amorphous parts or 100–110 °C plus nucleant for crystallized heat-resistant parts; thermoforming window is narrow just above Tg.

What surface finishes work on PLLA?

Takes printing, hot stamping and vacuum metallizing after corona/plasma treatment; can be vapour-smoothed or solvent-polished, but avoid alkaline cleaners and steam sterilization (use EO or e-beam/gamma with dose control).

PLLA chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
D-isomer (D-lactide) content<1–2 % for high-crystallinity / medical PLLA; higher D lowers Tm and crystallinity0 – 41
residual lactide monomertypically <0.1 % in medical grades0 – 0.50.1
Sn (tin octoate catalyst residue)limited to low ppm in implant grades0 – 0.020.01
L-lactic acid repeat unit (poly L-lactidring-opening polymerisation of L-lactide from fermented plant sugar≥ 96 (balance)—

PLLA TALC20 — frequently asked

What is PLLA TALC20 used for?

PLLA TALC20 is typically used for surgical sutures, bone fixation screws/pins, biodegradable textile fiber, rigid food packaging and high-heat 3D printing filament. In short: highest-heat PLA grade; medical resorbable standard; brittle, hydrolysis sensitive.

What is the yield strength of PLLA TALC20?

PLLA TALC20 has a typical yield strength of 47 MPa (6.82 ksi) and a tensile strength of 48 MPa (6.96 ksi) — weaker than 55% of polymer grades. Strength varies by condition: see the 8 listed tempers.

Is PLLA TALC20 easy to machine?

Reasonably — machinability is rated good (55/100, worse than 64% of polymer grades). Machines like acrylic with sharp, high-rake tools and air blast — keep speeds moderate and avoid coolant soak, since frictional heat above 60 °C softens the part and hot water accelerates hydrolysis.

Can PLLA TALC20 be welded?

Yes — weldability is rated good (60/100). Ultrasonic, hot-plate, vibration and laser welding all work well; solvent bonding with chloroform/dichloromethane or cyanoacrylate gives strong joints on non-crystalline surfaces.

What surface finishes work on PLLA TALC20?

Takes printing, hot stamping and vacuum metallizing after corona/plasma treatment; can be vapour-smoothed or solvent-polished, but avoid alkaline cleaners and steam sterilization (use EO or e-beam/gamma with dose control).

Can PLLA TALC20 be formed, bent or molded?

Dry to <250 ppm (4 h at 80 °C, or 45 °C for high-IV medical resin) before processing to prevent hydrolytic molecular-weight loss; mould at 190–220 °C melt with a cold tool (20–30 °C) for clear amorphous parts or 100–110 °C plus nucleant for crystallized heat-resistant parts; thermoforming window is narrow just above Tg.

What is the maximum service temperature of PLLA TALC20?

PLLA TALC20 is rated for continuous use to about 60°C (140 °F), and briefly to 80°C. Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

Sources

  1. Luminy L-series high heat PLA resin data sheets — TotalEnergies Corbion (2023)
  2. Purasorb PL / PLLA bioresorbable polymer data sheets — Corbion (2022)
  3. RESOMER L series (poly L-lactide) product information — Evonik (2022)
  4. Ingeo Biopolymer technical data sheets and processing guides — NatureWorks (2023)
  5. ISO 527-2 / ISO 178 / ISO 75 / ISO 306 plastics test methods — ISO (2019)
  6. ASTM F1925 Standard Specification for Semi-Crystalline Poly(lactide) Polymer and Copolymer Resins for Surgical Implants — ASTM (2022)
  7. Poly(lactic acid): Synthesis, Structures, Properties, Processing and Applications — Wiley (2010)
  8. CAMPUS / typical PLA compound datasheets — CWFG (2023)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.