FabDigitFabDigit

LCP-GF30 LW

Grade

ASTM D6779

LW = low-warpage glass + mineral filled

Use for flat, large or tight-tolerance parts where anisotropic shrinkage and warpage of pure GF grades is unacceptable.

High cost $$$$

Values for the LW condition

Other LCP-GF30 grades and fills

LCP-GF30 is listed in 6 conditions; see the grade overview at LCP-GF30.

Compare all 6 grades and fillsHide
Grade · open for datasheetBest forYield MPaTensile MPaElong. %Hardness
LWThis page
Low-warpage glass + mineral filled
Use for flat, large or tight-tolerance parts where anisotropic shrinkage and warpage of pure GF grades is unacceptable.—1402.292 HRM
High-heat Type I 30% GF LCP
Pick when lead-free SMT reflow at 260–280 °C or continuous 240 °C service is required (Xydar / Sumikasuper class).—1452—
Conductive / static-dissipative 30 % filled grade
Use for IC test sockets, burn-in hardware and wafer/chip handling parts requiring 10⁴–10⁹ Ω surface resistivity.—1451.892 HRM
Laser direct structuring / platable 30 % GF grade
For molded interconnect devices and antenna carriers where circuit traces are laser-activated and copper-plated on the molded part.—150292 HRM
low dielectric loss 30 % filled grade for mmWave / 5G
Select for antenna housings, 5G connectors and mmWave modules where Df at 10–77 GHz must stay below ~0.004.—1602.589 HRM
High-flow thin-wall 30 % GF grade
Choose for 0.15–0.3 mm wall fine-pitch connectors and long flow-length parts where fill pressure limits the standard grade.—1652.590 HRM

What is LCP-GF30 LW?

LCP-GF30 LW is LCP-GF30 in the LW grade — use for flat, large or tight-tolerance parts where anisotropic shrinkage and warpage of pure GF grades is unacceptable. LCP-GF30 LW has a tensile strength of 140 MPa (20.3 ksi), stronger than 95% of polymer grades. Elongation at break is 2.2% and the elastic modulus is 13 GPa (1.89 Msi). LCP-GF30 LW has a density of 1.75 g/cm³ (0.0632 lb/in³), heavier than 95% of polymer grades. Its glass-transition temperature is 120°C (248 °F).

Advantages

  • Stiff — 13 GPa (1.89 Msi), better than 98% of polymer grades
  • Conducts heat well — 0.45 W/m·K (0.26 BTU/hr·ft·°F), better than 97% of polymer grades
  • Low, predictable mold shrinkage — 0.25%, better than 93% of polymer grades
  • Low moisture uptake — 0.02%, better than 92% of polymer grades
  • Good corrosion resistance — 92/100, better than 91% of polymer grades

Limitations

  • Heavy — 1.75 g/cm³ (0.0632 lb/in³), worse than 95% of polymer grades
  • Limited ductility — 2.2%, worse than 92% of polymer grades
  • Limited formability — 8/100, worse than 91% of polymer grades
  • High embodied carbon — 9 kg CO₂/kg, worse than 88% of polymer grades
  • Difficult to machine — 45/100, worse than 78% of polymer grades

LCP-GF30 LW properties

Typical room-temperature values for LCP-GF30 LW; 22 are specific to this condition. Other listed values are LCP-GF30 reference data and may not represent this condition. Bars are the position among polymer grades.

Physical5

LCP-GF30 LW has a density of 1.75 g/cm³ (0.0632 lb/in³), heavier than 95% of polymer grades. Its glass-transition temperature is 120°C (248 °F).

Density1.75 g/cm³0.06 lb/in³
Melting Temperature (Tm)300°C572 °F
Glass Transition (Tg)120°C248 °F
Water Absorption (24 h)0.02%
Water Absorption (Saturation)0.1%

Mechanical11

LCP-GF30 LW has a tensile strength of 140 MPa (20.3 ksi), stronger than 95% of polymer grades. Elongation at break is 2.2% and the elastic modulus is 13 GPa (1.89 Msi).

Elastic (Young's) Modulus13 GPa1.9 Msi
Poisson's Ratio0.38
Tensile Strength (Ultimate)140 MPa20.3 ksi
Elongation at Break2.2%
Compressive Strength130 MPa18.9 ksi
Compressive Modulus11 GPa1.6 Msi
Flexural Strength175 MPa25.4 ksi
Flexural Modulus13 GPa1.9 Msi
Shear Strength75 MPa10.9 ksi
Izod Impact, Notched70 J/m1.3 ft·lbf/in
Hardness, Rockwell M92 HRM

Thermal10

LCP-GF30 LW is rated for continuous service to 215°C (419 °F). It conducts heat at 0.45 W/m·K (0.26 BTU/hr·ft·°F), better than 97% of polymer grades. Thermal expansion is 20 µm/m·K (11.1 µin/in·°F).

Thermal Conductivity0.45 W/m·K0.26 BTU/hr·ft·°F
Specific Heat Capacity1,100 J/kg·K0.26 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)20 µm/m·K11.1 µin/in·°F
Max Service Temperature (continuous)215°C419 °F
Min Service Temperature-50°C-58 °F
Heat Deflection Temp. @ 0.45 MPa250°C482 °F
Heat Deflection Temp. @ 1.8 MPa225°C437 °F
Flammability (UL 94)V-0 at 0.4–0.8 mm (inherently flame retardant, halogen-free); many grades 5VA at 1.5 mm
Limiting Oxygen Index42%
Max Service Temperature (short-term)280°C536 °F

Electrical7

LCP-GF30 LW is an electrical insulator with a dielectric strength of 35 kV/mm (889 V/mil) and a resistivity of 1×10¹³ Ω·m.

Electrical Resistivity1×10¹³ Ω·m3.94×10²⁰ µΩ·in
Dielectric Strength35 kV/mm889 V/mil
Dielectric Constant (1 MHz)3.9
Dissipation Factor (1 MHz)0.008
Volume Resistivity1×10¹⁵ Ω·cm
Surface Resistivity1×10¹⁵ Ω
Comparative Tracking Index (CTI)200 V

Chemical & Environmental3

Corrosion resistance is excellent (92/100), better than 91% of polymer grades. UV resistance is fair.

Corrosion ResistanceExcellent92/100
UV / Weathering ResistanceFair40/100
Chemical Resistance SummaryEssentially inert to acids, hydrocarbons, alcohols, ketones, chlorinated solvents, fuels and hydrolysis up to high temperature; attacked by hot concentrated caustic/strong bases, hot concentrated sulfuric acid and high-temperature steam over long exposure.

Sustainability4

Producing a kilogram of LCP-GF30 LW takes about 180 MJ of energy and emits 9 kg of CO₂ — more than 87% of polymer grades. Typical recycled content is 0%.

Embodied Energy (primary production)180 MJ/kg77,386 BTU/lb
Embodied Carbon (primary production)9 kg CO₂/kg
Embodied Water300 L/kg35.9 gal/lb
Typical Recycled Content0%

Manufacturability7

LCP-GF30 LW's machinability is fair (45/100, worse than 78% of polymer grades); weldability poor (25/100); formability not recommended (8/100).

MachinabilityFair45/100
WeldabilityPoor25/100
Formability (cold)Not recommended8/100
PolishabilityFair40/100
Mold Shrinkage0.25%
Processing Melt Temperature (typ.)320°C608 °F
Mold Temperature (typ.)110°C230 °F

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with LCP-GF30 LW

Is LCP-GF30 easy to machine?

Machines cleanly with sharp PCD or carbide tools at high speed and light feed, but glass fiber is abrasive and the skin layer fibrillates — avoid dull tools and use climb milling with air cooling.

Can LCP-GF30 be welded?

Weak weld/knit lines and poor ultrasonic welding due to the oriented skin; use laser transmission welding, adhesive bonding with surface treatment, or design mechanical/insert-molded joints instead.

Can LCP-GF30 be formed, bent or molded?

Dry 4 h at 140–150 °C, mold at 300–340 °C (Type I 350–400 °C) with 60–150 °C tools, high injection speed and small gates; extremely low viscosity fills 0.2 mm walls but flashes easily, so vent and clamp precisely and orient gates to control fiber-direction shrinkage.

What surface finishes work on LCP-GF30?

Accepts vacuum metallizing, electroless Cu/Ni plating (LDS or etched grades) and laser marking; painting/printing needs plasma or flame pretreatment because of the low-energy, chemically inert surface.

LCP-GF30 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
glass fiberchopped E-glass, silane sized, 10–13 µm diameter28 – 3230
pigments / processing additivescarbon black or TiO2, lubricant, nucleant; no halogen FR needed0 – 20.5
aromatic copolyester LCP resin (HBA / HNthermotropic liquid-crystal polyester matrix; Type II (HBA/HNA) or Type I (HBA/biphenol/terephthalic)≥ 68 (balance)—

LCP-GF30 LW — frequently asked

What is LCP-GF30 LW used for?

LCP-GF30 LW is typically used for structural electrical connectors, reflow-compatible surface-mount parts, precision brackets and chemical-resistant fittings. In short: stiffest general-purpose LCP; reduced anisotropy versus unfilled; brand-independent 30 % glass grade.

What is the tensile strength of LCP-GF30 LW?

LCP-GF30 LW has a typical tensile strength of 140 MPa (20.3 ksi) — stronger than 95% of polymer grades. Strength varies by condition: see the 6 listed tempers.

Is LCP-GF30 LW easy to machine?

Reasonably — machinability is rated fair (45/100, worse than 78% of polymer grades). Machines cleanly with sharp PCD or carbide tools at high speed and light feed, but glass fiber is abrasive and the skin layer fibrillates — avoid dull tools and use climb milling with air cooling.

Can LCP-GF30 LW be welded?

Not readily — weldability is rated poor (25/100). Weak weld/knit lines and poor ultrasonic welding due to the oriented skin; use laser transmission welding, adhesive bonding with surface treatment, or design mechanical/insert-molded joints instead.

What surface finishes work on LCP-GF30 LW?

Accepts vacuum metallizing, electroless Cu/Ni plating (LDS or etched grades) and laser marking; painting/printing needs plasma or flame pretreatment because of the low-energy, chemically inert surface.

Can LCP-GF30 LW be formed, bent or molded?

Dry 4 h at 140–150 °C, mold at 300–340 °C (Type I 350–400 °C) with 60–150 °C tools, high injection speed and small gates; extremely low viscosity fills 0.2 mm walls but flashes easily, so vent and clamp precisely and orient gates to control fiber-direction shrinkage.

What is the maximum service temperature of LCP-GF30 LW?

LCP-GF30 LW is rated for continuous use to about 215°C (419 °F), and briefly to 280°C. Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

Sources

  1. Vectra LCP Product and Processing Guide (A130 series) — Celanese (2023)
  2. Zenite LCP grade data (6130 series) — Celanese/DuPont (2022)
  3. Sumikasuper LCP E-series technical data — Sumitomo Chemical (2023)
  4. Xydar LCP G-series datasheet — Solvay (2022)
  5. CAMPUS ISO 10350 single-point data, LCP GF30 compounds — CAMPUS Plastics (2024)
  6. Engineered Materials Handbook Vol. 2: Engineering Plastics — ASM International (1988)
  7. UL 94 Flammability of Plastic Materials — Underwriters Laboratories (2020)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.