FabDigitFabDigit

LCP CF30 vs LCP GF30

Polymer · grade comparison

LCP CF30 and LCP-GF30 are both polymer grades, compared here in the CF30 condition. LCP CF30 is the stronger of the two: tensile strength 195 MPa (28.3 ksi) against 180 MPa (26.1 ksi) for LCP-GF30, about 8% more. In exchange, LCP-GF30 is the more ductile: elongation 2.8% versus 1.2% for LCP CF30. LCP CF30 is lighter (1.53 g/cm³ vs 1.61 g/cm³ for LCP-GF30) and LCP CF30 is stiffer (27 GPa vs 15 GPa). On the shop floor, LCP-GF30 machines more easily (good vs fair) and LCP-GF30 sits in a lower cost tier (high, $$$$) than LCP CF30 (specialty, $$$$$).

LCP CF30Choose it when strength drives the design, or when weight is the constraint.

LCP-GF30Choose it when the part is bent, formed or impact-loaded, or when the part is machined in volume.

LCP CF30 vs LCP-GF30: properties

LCP CF30LCP-GF30

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

27 GPa3.9 Msi
15 GPa2.2 Msi

Poisson's Ratio

0.35
0.38

Tensile Strength (Ultimate)

195 MPa28.3 ksi
180 MPa26.1 ksi

Elongation at Break

1.2%
2.8%

Compressive Strength

130 MPa18.9 ksi
150 MPa21.8 ksi

Flexural Strength

250 MPa36.3 ksi
225 MPa32.6 ksi

Flexural Modulus

24 GPa3.5 Msi
14.5 GPa2.1 Msi

Shear Strength

70 MPa10.2 ksi
90 MPa13.1 ksi

Izod Impact, Notched

80 J/m1.5 ft·lbf/in
100 J/m1.9 ft·lbf/in

Hardness, Shore D

88 Shore D
—

Hardness, Rockwell M

85 HRM
90 HRM

Compressive Modulus

—
11 GPa1.6 Msi

Physical

Density and transition temperatures.

Density

1.53 g/cm³0.06 lb/in³
1.61 g/cm³0.06 lb/in³

Melting Temperature (Tm)

280°C536 °F
300°C572 °F

Glass Transition (Tg)

110°C230 °F
120°C248 °F

Water Absorption (24 h)

0.03%
0.02%

Water Absorption (Saturation)

0.08%
0.1%

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

1.2 W/m·K0.69 BTU/hr·ft·°F
0.4 W/m·K0.23 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

6 µm/m·K3.3 µin/in·°F
12 µm/m·K6.7 µin/in·°F

Max Service Temperature (continuous)

230°C446 °F
220°C428 °F

Heat Deflection Temp. @ 0.45 MPa

255°C491 °F
260°C500 °F

Heat Deflection Temp. @ 1.8 MPa

240°C464 °F
230°C446 °F

Same in both: Specific Heat Capacity 1,100 J/kg·K0.26 BTU/lb·°F · Min Service Temperature -50°C-58 °F · Limiting Oxygen Index 40% · Max Service Temperature (short-term) 280°C536 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

10 Ω·m3.94×10⁸ µΩ·in
1×10¹³ Ω·m3.94×10²⁰ µΩ·in

Dielectric Constant (1 MHz)

4
3.9

Volume Resistivity

1,000 Ω·cm
1×10¹⁵ Ω·cm

Surface Resistivity

100,000 Ω
1×10¹⁵ Ω

Same in both: Dielectric Strength 35 kV/mm889 V/mil · Dissipation Factor (1 MHz) 0.008 · Comparative Tracking Index (CTI) 200 V

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

UV / Weathering Resistance

60 / 100
40 / 100

Same in both: Corrosion Resistance 92 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
55 / 100

Polishability

30 / 100
40 / 100

Mold Shrinkage

0.1%
0.2%

Processing Melt Temperature (typ.)

330°C626 °F
320°C608 °F

Mold Temperature (typ.)

90°C194 °F
110°C230 °F

Same in both: Weldability 25 / 100 · Formability (cold) 10 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

200 MJ/kg85,985 BTU/lb
180 MJ/kg77,386 BTU/lb

Embodied Water

—
300 L/kg35.9 gal/lb

Same in both: Embodied Carbon (primary production) 9 kg CO₂/kg · Typical Recycled Content 0%

Strength versus weight

Yield strength against density for every polymer grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

0.1110100123Density (g/cm³)Yield strength (MPa) — log scaleLCP

Manufacturing and finishing

CapabilityLCP CF30LCP-GF30
Injection moldingYes—
Default conditionGF30—
Relative cost$$$$$ Specialty$$$$ High
Min. machined wall——
Best machined surface——
Chrome Plating (Plastic)Yes—
EMI Shielding CoatingYes—
Soft Touch CoatingYes—
Spray PaintingYes—
UV CoatingYes—

LCP CF30 vs LCP-GF30 — frequently asked

Is LCP CF30 stronger than LCP-GF30?

Yes. LCP CF30 has a typical tensile strength of 195 MPa (28.3 ksi) against 180 MPa (26.1 ksi) for LCP-GF30 — about 8% more.

Which is cheaper, LCP CF30 or LCP-GF30?

LCP-GF30 is the lower-cost material: it sits in the high tier ($$$$) while LCP CF30 is specialty ($$$$$). Part price depends far more on geometry, tolerance and quantity than on raw stock — upload a CAD file for a live quote.

Which is easier to machine, LCP CF30 or LCP-GF30?

LCP-GF30. Its machinability rates good (55/100) against fair (40/100) for LCP CF30.

Ready to make it?

Upload a CAD file and FabDigit prices the part in LCP CF30 and LCP-GF30 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.