FabDigitFabDigit

LCP-GF30 vs LCP Type I

Polymer · grade comparison

LCP-GF30 and LCP Type I are both polymer grades. LCP-GF30 is the stronger of the two: tensile strength 180 MPa (26.1 ksi) against 135 MPa (19.6 ksi) for LCP Type I, about 33% more. LCP-GF30 is the more ductile: elongation 2.8% versus 2.5% for LCP Type I. LCP Type I is lighter (1.38 g/cm³ vs 1.61 g/cm³ for LCP-GF30) and LCP-GF30 is stiffer (15 GPa vs 11 GPa).

LCP-GF30Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

LCP Type IChoose it when weight is the constraint.

LCP-GF30 vs LCP Type I: properties

LCP-GF30LCP Type I

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

15 GPa2.2 Msi
11 GPa1.6 Msi

Tensile Strength (Ultimate)

180 MPa26.1 ksi
135 MPa19.6 ksi

Elongation at Break

2.8%
2.5%

Compressive Strength

150 MPa21.8 ksi
65 MPa9.4 ksi

Compressive Modulus

11 GPa1.6 Msi
7 GPa1 Msi

Flexural Strength

225 MPa32.6 ksi
145 MPa21 ksi

Flexural Modulus

14.5 GPa2.1 Msi
10 GPa1.5 Msi

Shear Strength

90 MPa13.1 ksi
55 MPa8 ksi

Izod Impact, Notched

100 J/m1.9 ft·lbf/in
180 J/m3.4 ft·lbf/in

Hardness, Rockwell M

90 HRM
75 HRM

Shear Modulus

—
1.2 GPa0.17 Msi

Hardness, Shore D

—
88 Shore D

Same in both: Poisson's Ratio 0.38

Physical

Density and transition temperatures.

Density

1.61 g/cm³0.06 lb/in³
1.38 g/cm³0.05 lb/in³

Melting Temperature (Tm)

300°C572 °F
355°C671 °F

Glass Transition (Tg)

120°C248 °F
145°C293 °F

Same in both: Water Absorption (24 h) 0.02% · Water Absorption (Saturation) 0.1%

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

0.4 W/m·K0.23 BTU/hr·ft·°F
0.3 W/m·K0.17 BTU/hr·ft·°F

Specific Heat Capacity

1,100 J/kg·K0.26 BTU/lb·°F
1,150 J/kg·K0.27 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

12 µm/m·K6.7 µin/in·°F
8 µm/m·K4.4 µin/in·°F

Min Service Temperature

-50°C-58 °F
-100°C-148 °F

Heat Deflection Temp. @ 0.45 MPa

260°C500 °F
275°C527 °F

Heat Deflection Temp. @ 1.8 MPa

230°C446 °F
240°C464 °F

Max Service Temperature (short-term)

280°C536 °F
300°C572 °F

Same in both: Max Service Temperature (continuous) 220°C428 °F · Limiting Oxygen Index 40%

Electrical

Conductivity and insulation.

Dielectric Constant (1 MHz)

3.9
3.3

Dissipation Factor (1 MHz)

0.008
0.004

Same in both: Electrical Resistivity 1×10¹³ Ω·m3.94×10²⁰ µΩ·in · Dielectric Strength 35 kV/mm889 V/mil · Volume Resistivity 1×10¹⁵ Ω·cm · Surface Resistivity 1×10¹⁵ Ω · Comparative Tracking Index (CTI) 200 V

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

UV / Weathering Resistance

40 / 100
45 / 100

Same in both: Corrosion Resistance 92 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
62 / 100

Weldability

25 / 100
20 / 100

Formability (cold)

10 / 100
20 / 100

Polishability

40 / 100
45 / 100

Mold Shrinkage

0.2%
0.1%

Processing Melt Temperature (typ.)

320°C608 °F
385°C725 °F

Mold Temperature (typ.)

110°C230 °F
120°C248 °F

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

180 MJ/kg77,386 BTU/lb
250 MJ/kg107,481 BTU/lb

Same in both: Embodied Carbon (primary production) 9 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 0%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

112 kN·m/kg
98 kN·m/kg

Specific Stiffness (E / density)

9.3 MN·m/kg
8 MN·m/kg

Same in both: Thermal Diffusivity 0.2 mm²/s · Thermal Shock Resistance Index 0

Strength versus weight

Yield strength against density for every polymer grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

0.1110100123Density (g/cm³)Yield strength (MPa) — log scale

Manufacturing and finishing

CapabilityLCP-GF30LCP Type I
Default condition——
Relative cost$$$$ High$$$$ High
Min. machined wall——
Best machined surface——

LCP-GF30 vs LCP Type I — frequently asked

Is LCP-GF30 stronger than LCP Type I?

Yes. LCP-GF30 has a typical tensile strength of 180 MPa (26.1 ksi) against 135 MPa (19.6 ksi) for LCP Type I — about 33% more.

Which is cheaper, LCP-GF30 or LCP Type I?

Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, LCP-GF30 or LCP Type I?

LCP Type I, by a small margin. Both rate good for machinability — 62/100 against 55/100 for LCP-GF30; for welding the order is LCP-GF30 first (poor, 25/100) then LCP Type I (poor, 20/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in LCP-GF30 and LCP Type I side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.