FabDigit

LCP Type III

ASTM D6779 · ISO LCP

Lower-cost LCP copolyester family based on naphthalene dicarboxylic acid units, offering a balance of processability and performance below Type I/II grades; used in general industrial and consumer parts.

High cost $$$$

Reference datasheet — LCP Type III is not in the instant-quote catalog. Upload your part and an engineer will quote it in this grade or suggest the closest stocked equivalent.

LCP Type III grades and fills

LCP Type III is supplied in 10 conditions, soft to hard.

Compare all 10 grades and fillsHide
Grade · open for datasheetBest forYield MPaTensile MPaElong. %Hardness
30 % mineral filled
Mineral filler for low warpage, isotropic shrinkage and better weld-line appearance; less abrasive on tools than glass.1101.8
Bearing / lubricated grade
Choose for low-friction, low-wear sliding parts (bushings, gears, pump vanes) running dry at elevated temperature.1151.887 Shore D
GF/MF hybrid
Balanced grade when both dimensional stability (low anisotropy) and stiffness are needed, e.g. flat thin covers.1301.690 Shore D
ESD / conductive grade
For semiconductor and electronics handling trays where 10⁴–10⁹ Ω·cm static dissipation is specified.1301.589 Shore D
LDS grade
Pick when circuit traces are plated directly onto the moulded part (MID antennas, module carriers).1401.690 Shore D
High-flow / thin-wall grade
Lowest-viscosity Type III variant for 0.1–0.3 mm walls and fine-pitch connectors with long flow paths.1452.588 Shore D
15 % glass-fibre reinforced
Light reinforcement to lift stiffness and HDT while keeping good flow for very thin connector walls.1552.5
30 % glass-fibre reinforced
Workhorse grade for SMT connectors, sockets and structural parts needing high HDT and stiffness with low warp.1601.8
40 % glass-fibre reinforced
Maximum stiffness/HDT glass grade for load-bearing housings and parts exposed to lead-free reflow.1701.5
30 % carbon-fibre reinforced
Highest specific stiffness plus static-dissipative behaviour; for lightweight precision and wafer-handling parts.1751.3

Supply forms, finishes and certifications

Ways LCP Type III is supplied — form, process route, surface or paperwork — without a datasheet of their own. The property values above apply.

OptionWhat it isType
FDA
Food-contact / medical compliant gradeCertification
NATDefault
Unfilled / NaturalStandard supply

What is LCP Type III?

Lower-cost LCP copolyester family based on naphthalene dicarboxylic acid units, offering a balance of processability and performance below Type I/II grades; used in general industrial and consumer parts. LCP Type III has a density of 1.4 g/cm³ (0.0506 lb/in³), heavier than 79% of polymer grades. Its glass-transition temperature is 105°C (221 °F). LCP Type III has a tensile strength of 150 MPa (21.8 ksi), stronger than 95% of polymer grades. Elongation at break is 3% and the elastic modulus is 10 GPa (1.45 Msi).

What is LCP Type III used for?

  • general industrial connectors
  • cookware/appliance parts
  • fiber-optic components
  • chemical process fittings

Advantages

  • Low, predictable mold shrinkage — 0.15%, better than 97% of polymer grades
  • Stiff — 10 GPa (1.45 Msi), better than 95% of polymer grades
  • Low moisture uptake — 0.02%, better than 92% of polymer grades
  • Good corrosion resistance — 92/100, better than 91% of polymer grades
  • High service temperature — 170°C (338 °F), better than 83% of polymer grades

Limitations

  • High embodied carbon — 8.5 kg CO₂/kg, worse than 85% of polymer grades
  • Limited ductility — 3%, worse than 83% of polymer grades
  • Heavy — 1.4 g/cm³ (0.0506 lb/in³), worse than 79% of polymer grades

LCP Type III properties

Typical room-temperature values; bars are the position among polymer grades.

Physical5

LCP Type III has a density of 1.4 g/cm³ (0.0506 lb/in³), heavier than 79% of polymer grades. Its glass-transition temperature is 105°C (221 °F).

Density1.4 g/cm³0.05 lb/in³
Melting Temperature (Tm)285°C545 °F
Glass Transition (Tg)105°C221 °F
Water Absorption (24 h)0.02%
Water Absorption (Saturation)0.06%

Mechanical12

LCP Type III has a tensile strength of 150 MPa (21.8 ksi), stronger than 95% of polymer grades. Elongation at break is 3% and the elastic modulus is 10 GPa (1.45 Msi).

Elastic (Young's) Modulus10 GPa1.5 Msi
Shear Modulus1.2 GPa0.17 Msi
Poisson's Ratio0.36
Tensile Strength (Ultimate)150 MPa21.8 ksi
Elongation at Break3%
Compressive Strength65 MPa9.4 ksi
Flexural Strength140 MPa20.3 ksi
Flexural Modulus9 GPa1.3 Msi
Shear Strength55 MPa8 ksi
Izod Impact, Notched200 J/m3.7 ft·lbf/in
Hardness, Shore D88 Shore D
Hardness, Rockwell M72 HRM

Thermal10

LCP Type III is rated for continuous service to 170°C (338 °F). It conducts heat at 0.3 W/m·K (0.173 BTU/hr·ft·°F), better than 83% of polymer grades. Thermal expansion is 8 µm/m·K (4.44 µin/in·°F).

Thermal Conductivity0.3 W/m·K0.17 BTU/hr·ft·°F
Specific Heat Capacity1,200 J/kg·K0.29 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)8 µm/m·K4.4 µin/in·°F
Max Service Temperature (continuous)170°C338 °F
Min Service Temperature-50°C-58 °F
Heat Deflection Temp. @ 0.45 MPa225°C437 °F
Heat Deflection Temp. @ 1.8 MPa185°C365 °F
Flammability (UL 94)V-0 at ≥0.4 mm without added flame retardant (inherently flame retardant, very low smoke)
Limiting Oxygen Index38%
Max Service Temperature (short-term)230°C446 °F

Electrical7

LCP Type III is an electrical insulator with a dielectric strength of 35 kV/mm (889 V/mil) and a resistivity of 1×10¹³ Ω·m.

Electrical Resistivity1×10¹³ Ω·m3.94×10²⁰ µΩ·in
Dielectric Strength35 kV/mm889 V/mil
Dielectric Constant (1 MHz)3.4
Dissipation Factor (1 MHz)0.004
Volume Resistivity1×10¹⁵ Ω·cm
Surface Resistivity1×10¹⁵ Ω
Comparative Tracking Index (CTI)200 V

Chemical & Environmental3

Corrosion resistance is excellent (92/100), better than 91% of polymer grades. UV resistance is fair.

Corrosion ResistanceExcellent92/100
UV / Weathering ResistanceFair45/100
Chemical Resistance SummaryExcellent against acids, hydrocarbons, fuels, solvents, hydrolysis and steam; attacked by hot concentrated alkali and by strong oxidising acids at elevated temperature; not soluble in common solvents (no solvent bonding possible).

Sustainability4

Producing a kilogram of LCP Type III takes about 180 MJ of energy and emits 8.5 kg of CO₂ — more than 87% of polymer grades. Typical recycled content is 0%.

Embodied Energy (primary production)180 MJ/kg77,386 BTU/lb
Embodied Carbon (primary production)8.5 kg CO₂/kg
Embodied Water300 L/kg35.9 gal/lb
Typical Recycled Content0%

Manufacturability8

LCP Type III's machinability is good (55/100, worse than 64% of polymer grades); weldability poor (30/100); formability poor (20/100).

MachinabilityGood55/100
WeldabilityPoor30/100
Formability (cold)Poor20/100
PolishabilityFair40/100
Mold Shrinkage0.15%
Melt Flow Rate40 g/10 min
Processing Melt Temperature (typ.)310°C590 °F
Mold Temperature (typ.)90°C194 °F

Common Calculations4

Specific Strength (UTS / density)calculated107 kN·m/kg
Specific Stiffness (E / density)calculated7.1 MN·m/kg
Thermal Diffusivitycalculated0.2 mm²/s
Thermal Shock Resistance Indexcalculated1

Values are nominal handbook figures for design screening. Certified mill or lot data ships with every FabDigit order on request.

Strength versus weight in the polymer family

Yield strength against density for every polymer grade FabDigit runs. LCP Type III is highlighted; hover a dot for its name, or open the interactive family chart.

0.1110100123Density (g/cm³)Yield strength (MPa) — log scale

Working with LCP Type III

Is LCP Type III easy to machine?

Machinable with sharp carbide/PCD tooling and high speed, light feed; the skin fibrillates and filled grades are abrasive, so avoid dull tools and deburr carefully.

Can LCP Type III be welded?

No solvent bonding; use laser or ultrasonic (near-field) welding, heat staking or adhesives after plasma/flame surface activation — weld and knit lines carry only a fraction of the bulk strength.

Can LCP Type III be formed, bent or molded?

Injection mould at 285–330 °C melt with 60–130 °C tools, thoroughly dried (≈150 °C, 4 h, <0.01 % moisture); design gates to control the highly directional fibrillar orientation and place weld lines away from load paths.

LCP Type III chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
4-hydroxybenzoic acid (HBA) unitsrigid mesogenic backbone unit50 – 7562
naphthalene units (2,6-HNA / 2,6-naphthakink unit that lowers Tm and gives Type III processability15 – 4025
terephthalic / isophthalic acid unitscomonomer for melt-temperature control0 – 208
aromatic diol / aminophenol unitsstoichiometric partner for diacid units0 – 155
LCP copolyester resinbalance; fillers listed per variant (glass fibre, mineral, carbon fibre 15–40 wt %)balance

What surface finishes work on LCP Type III?

Accepts vapour-deposited/electroless metallisation and laser marking; painting or printing needs surface pretreatment because the resin is inherently low-energy and solvent resistant.

Equivalent designations

Standards and trade names that resolve to LCP Type III in FabDigit's catalog. Equivalence is nominal — check the exact specification when certification matters.

ASTM
D6779
ISO
LCP

How much does LCP Type III cost?

LCP Type III is a high-cost polymer ($$$$), pricier than about 78% of the materials FabDigit quotes. Part price depends far more on geometry, tolerance and quantity than on the raw stock — upload a CAD file for a live quote.

LCP Type III — frequently asked

What is LCP Type III used for?

LCP Type III is typically used for general industrial connectors, cookware/appliance parts, fiber-optic components and chemical process fittings. In short: lowest-cost LCP family; balanced processability and performance; metallizable with LDS grades.

What is the tensile strength of LCP Type III?

LCP Type III has a typical tensile strength of 150 MPa (21.8 ksi) — stronger than 95% of polymer grades. Strength varies by condition: see the 10 listed tempers.

Is LCP Type III easy to machine?

Reasonably — machinability is rated good (55/100, worse than 64% of polymer grades). Machinable with sharp carbide/PCD tooling and high speed, light feed; the skin fibrillates and filled grades are abrasive, so avoid dull tools and deburr carefully.

Can LCP Type III be welded?

Not readily — weldability is rated poor (30/100). No solvent bonding; use laser or ultrasonic (near-field) welding, heat staking or adhesives after plasma/flame surface activation — weld and knit lines carry only a fraction of the bulk strength.

What surface finishes work on LCP Type III?

Accepts vapour-deposited/electroless metallisation and laser marking; painting or printing needs surface pretreatment because the resin is inherently low-energy and solvent resistant.

Can LCP Type III be formed, bent or molded?

Injection mould at 285–330 °C melt with 60–130 °C tools, thoroughly dried (≈150 °C, 4 h, <0.01 % moisture); design gates to control the highly directional fibrillar orientation and place weld lines away from load paths.

What is the maximum service temperature of LCP Type III?

LCP Type III is rated for continuous use to about 170°C (338 °F), and briefly to 230°C. Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

How much does LCP Type III cost?

LCP Type III is a high-cost polymer ($$$$), pricier than about 78% of the materials FabDigit quotes. Part price depends far more on geometry, tolerance and quantity than on the raw stock — upload a CAD file for a live quote.

Sources

  1. ASTM D6779 – Standard Classification System for Liquid Crystal Polymer (LCP) Materials — ASTM International (2022)
  2. Vectra LCP product and processing guides — Celanese (2023)
  3. LAPEROS LCP technical data — Polyplastics (2023)
  4. SUMIKASUPER LCP grade list — Sumitomo Chemical (2022)
  5. CAMPUS plastics database – LCP grade data — CWFG / CAMPUS consortium (2024)
  6. Engineered Materials Handbook, Vol. 2: Engineering Plastics — ASM International (1988)

Property data is compiled from published supplier and standards handbooks and normalised for comparison; hardness values on non-Brinell scales are converted approximately for charting only. Manufacturability limits are FabDigit quote-engine defaults and may be relaxed by engineering review. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.