FabDigitFabDigit

Vectra LUB (Lubricated / wear grade)

Additive grade

ISO LCP

Bearing and sliding-contact version with reduced friction and wear rate at high PV and high temperature.

High cost $$$$

Values for the LUB condition

Other Vectra grades and fills

Vectra is listed in 10 conditions; see the grade overview at Vectra.

Compare all 10 grades and fillsHide
Grade · open for datasheetBest forYield MPaTensile MPaElong. %Hardness
Mineral / mineral-glass filled, low-warpage
Choose when flatness and isotropic shrinkage matter more than peak strength — e.g. flat covers, sockets with tight coplanarity.—120289 Shore D
laser direct structuring, plateable
Contains a laser-activatable metal-organic additive so circuit traces can be laser-written and copper-plated on the molded part (MID/antenna).—1301.590 Shore D
LUBThis page
Lubricated / wear grade
Bearing and sliding-contact version with reduced friction and wear rate at high PV and high temperature.—1301.885 Shore D
ESD / conductive
Static-dissipative to conductive LCP for semiconductor handling trays, test sockets and EMI-relevant hardware.—1501.789 Shore D
High-heat E-series, 30% glass, lead-free reflow
Higher-melting E-series chemistry for 260–290 °C lead-free reflow with low blistering and very low outgassing.—1602—
50% glass-fiber reinforced
Maximum stiffness/HDT and lowest CTE for structural or coplanarity-critical parts; flow and toughness drop noticeably.—1701.5—
15% glass-fiber reinforced
Light glass loading when you need better dimensional balance and stiffness but must keep thin-wall flow close to unfilled.—1752.890 Shore D
A950Default
Unfilled natural A-series LCP
Base unfilled HBA/HNA resin — pick for maximum flow, thinnest walls, best chemical/dielectric purity and self-reinforced anisotropic strength.—1823.4—
30% glass-fiber reinforced
The default choice for SMT connectors and reflow-exposed housings: high modulus, 230 °C HDT, controlled warpage.—1852.4—
30% carbon-fiber reinforced
Highest specific stiffness plus static-dissipative surface and low wear — pick for precision fixtures, wafer handling and ESD-sensitive parts.—2001.4—

What is Vectra LUB?

Vectra LUB is Vectra in the LUB grade — bearing and sliding-contact version with reduced friction and wear rate at high PV and high temperature. Vectra LUB has a tensile strength of 130 MPa (18.9 ksi), stronger than 94% of polymer grades. Elongation at break is 1.8% and the elastic modulus is 12 GPa (1.74 Msi). Vectra LUB has a density of 1.62 g/cm³ (0.0585 lb/in³), heavier than 94% of polymer grades. Its glass-transition temperature is 110°C (230 °F). A950 is the default condition FabDigit quotes; LUB is available on request or by drawing note.

Advantages

  • Stiff — 12 GPa (1.74 Msi), better than 98% of polymer grades
  • Low, predictable mold shrinkage — 0.2%, better than 94% of polymer grades
  • Conducts heat well — 0.35 W/m·K (0.202 BTU/hr·ft·°F), better than 91% of polymer grades
  • Low moisture uptake — 0.03%, better than 88% of polymer grades
  • High service temperature — 200°C (392 °F), better than 87% of polymer grades

Limitations

  • Limited ductility — 1.8%, worse than 97% of polymer grades
  • Heavy — 1.62 g/cm³ (0.0585 lb/in³), worse than 94% of polymer grades
  • Limited formability — 8/100, worse than 91% of polymer grades
  • High embodied carbon — 8.5 kg CO₂/kg, worse than 85% of polymer grades
  • Difficult to weld — 15/100, worse than 78% of polymer grades

Vectra LUB properties

Typical room-temperature values for Vectra LUB; 24 are specific to this condition. Other listed values are Vectra reference data and may not represent this condition. Bars are the position among polymer grades.

Physical5

Vectra LUB has a density of 1.62 g/cm³ (0.0585 lb/in³), heavier than 94% of polymer grades. Its glass-transition temperature is 110°C (230 °F).

Density1.62 g/cm³0.06 lb/in³
Melting Temperature (Tm)280°C536 °F
Glass Transition (Tg)110°C230 °F
Water Absorption (24 h)0.03%
Water Absorption (Saturation)0.1%

Mechanical9

Vectra LUB has a tensile strength of 130 MPa (18.9 ksi), stronger than 94% of polymer grades. Elongation at break is 1.8% and the elastic modulus is 12 GPa (1.74 Msi).

Elastic (Young's) Modulus12 GPa1.7 Msi
Poisson's Ratio0.35
Tensile Strength (Ultimate)130 MPa18.9 ksi
Elongation at Break1.8%
Flexural Strength140 MPa20.3 ksi
Flexural Modulus12 GPa1.7 Msi
Izod Impact, Notched50 J/m0.94 ft·lbf/in
Hardness, Shore D85 Shore D
Hardness, Rockwell M65 HRM

Thermal10

Vectra LUB is rated for continuous service to 200°C (392 °F). It conducts heat at 0.35 W/m·K (0.202 BTU/hr·ft·°F), better than 91% of polymer grades. Thermal expansion is 5 µm/m·K (2.78 µin/in·°F).

Thermal Conductivity0.35 W/m·K0.2 BTU/hr·ft·°F
Specific Heat Capacity1,200 J/kg·K0.29 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)5 µm/m·K2.8 µin/in·°F
Max Service Temperature (continuous)200°C392 °F
Min Service Temperature-50°C-58 °F
Heat Deflection Temp. @ 0.45 MPa240°C464 °F
Heat Deflection Temp. @ 1.8 MPa215°C419 °F
Flammability (UL 94)V-0 at 0.4 mm
Limiting Oxygen Index38%
Max Service Temperature (short-term)280°C536 °F

Electrical7

Vectra LUB is an electrical insulator with a dielectric strength of 35 kV/mm (889 V/mil) and a resistivity of 1×10¹² Ω·m.

Electrical Resistivity1×10¹² Ω·m3.94×10¹⁹ µΩ·in
Dielectric Strength35 kV/mm889 V/mil
Dielectric Constant (1 MHz)3.3
Dissipation Factor (1 MHz)0.005
Volume Resistivity1×10¹⁵ Ω·cm
Surface Resistivity1×10¹⁵ Ω
Comparative Tracking Index (CTI)200 V

Chemical & Environmental3

Corrosion resistance is excellent (90/100), better than 82% of polymer grades. UV resistance is fair.

Corrosion ResistanceExcellent90/100
UV / Weathering ResistanceFair40/100
Chemical Resistance SummaryOutstanding against acids, hydrocarbons, solvents, oils, alcohols and hydrolysis (steam/boiling water); essentially insoluble at room temperature. Attacked by hot concentrated caustic/strong bases and by hot chlorinated-phenol type solvents; long-term high-pH steam causes surface hydrolysis.

Sustainability3

Producing a kilogram of Vectra LUB takes about 180 MJ of energy and emits 8.5 kg of CO₂ — more than 87% of polymer grades. Typical recycled content is 0%.

Embodied Energy (primary production)180 MJ/kg77,386 BTU/lb
Embodied Carbon (primary production)8.5 kg CO₂/kg
Typical Recycled Content0%

Manufacturability7

Vectra LUB's machinability is good (60/100, better than 51% of polymer grades); weldability poor (15/100); formability not recommended (8/100).

MachinabilityGood60/100
WeldabilityPoor15/100
Formability (cold)Not recommended8/100
PolishabilityFair40/100
Mold Shrinkage0.2%
Processing Melt Temperature (typ.)300°C572 °F
Mold Temperature (typ.)90°C194 °F

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with Vectra LUB

Is Vectra easy to machine?

Machinable with sharp carbide/PCD tools and high speed, low feed, but the fibrillar skin tends to fuzz and delaminate at edges; avoid deep interrupted cuts and support thin webs.

Can Vectra be welded?

Solvent and ultrasonic welding are unreliable because of the anisotropic skin; use laser transmission welding, heat staking, insert molding or mechanical/adhesive joints (surface pretreatment required for bonding).

Can Vectra be formed, bent or molded?

Inject at 285–330 °C (E-series to ~350 °C) with 40–130 °C molds, small gates and very high injection speed; dry 4 h at 150 °C, place gates to steer flow because weld lines retain only ~20–40 % of flow-direction strength.

What surface finishes work on Vectra?

Molded surfaces reproduce the tool finish well; can be laser-marked, vacuum-metallized or (with LDS grades) laser-activated and electrolessly copper/nickel/gold plated — painting needs plasma or primer pretreatment.

Vectra chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
4-hydroxybenzoic acid (HBA) unitA-series copolyester backbone70 – 7573
glass fiber0 for unfilled A950; 15/30/40/50 % in reinforced grades0 – 500
carbon fiberA230-type grades0 – 300
mineral filler (talc/wollastonite)low-warpage grades0 – 400
6-hydroxy-2-naphthoic acid (HNA) unitbalance of A-series backbone≥ 25 (balance)—

Vectra LUB — frequently asked

What is Vectra LUB used for?

Vectra LUB is typically used for SMT connectors, camera module housings, micro-precision gears and RF/antenna components. In short: industry reference LCP resin; high-flow thin-wall molding; LDS-platable grades available.

What is the tensile strength of Vectra LUB?

Vectra LUB has a typical tensile strength of 130 MPa (18.9 ksi) — stronger than 94% of polymer grades. Strength varies by condition: see the 10 listed tempers.

Is Vectra LUB easy to machine?

Reasonably — machinability is rated good (60/100, better than 51% of polymer grades). Machinable with sharp carbide/PCD tools and high speed, low feed, but the fibrillar skin tends to fuzz and delaminate at edges; avoid deep interrupted cuts and support thin webs.

Can Vectra LUB be welded?

Not readily — weldability is rated poor (15/100). Solvent and ultrasonic welding are unreliable because of the anisotropic skin; use laser transmission welding, heat staking, insert molding or mechanical/adhesive joints (surface pretreatment required for bonding).

What surface finishes work on Vectra LUB?

Molded surfaces reproduce the tool finish well; can be laser-marked, vacuum-metallized or (with LDS grades) laser-activated and electrolessly copper/nickel/gold plated — painting needs plasma or primer pretreatment.

Can Vectra LUB be formed, bent or molded?

Inject at 285–330 °C (E-series to ~350 °C) with 40–130 °C molds, small gates and very high injection speed; dry 4 h at 150 °C, place gates to steer flow because weld lines retain only ~20–40 % of flow-direction strength.

What is the maximum service temperature of Vectra LUB?

Vectra LUB is rated for continuous use to about 200°C (392 °F), and briefly to 280°C. Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

Sources

  1. Vectra Liquid Crystal Polymer (LCP) product and processing brochure — Celanese (2023)
  2. CAMPUS plastics data for Vectra A950 / A130 / E130i — CAMPUS / Celanese (2023)
  3. ISO 527, ISO 178, ISO 75, ISO 180 test methods — ISO (2019)
  4. UL 94 Tests for Flammability of Plastic Materials — UL (2020)
  5. Engineering Plastics — Engineered Materials Handbook Vol. 2 (LCP chapter) — ASM International (1988)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.