FabDigitFabDigit

Vectra E130i

Grade

ISO LCP

E130i = high-heat E-series, 30% glass, lead-free reflow

Higher-melting E-series chemistry for 260–290 °C lead-free reflow with low blistering and very low outgassing.

High cost $$$$

Values for the E130i condition

Other Vectra grades and fills

Vectra is listed in 10 conditions; see the grade overview at Vectra.

Compare all 10 grades and fillsHide
Grade · open for datasheetBest forYield MPaTensile MPaElong. %Hardness
Mineral / mineral-glass filled, low-warpage
Choose when flatness and isotropic shrinkage matter more than peak strength — e.g. flat covers, sockets with tight coplanarity.—120289 Shore D
laser direct structuring, plateable
Contains a laser-activatable metal-organic additive so circuit traces can be laser-written and copper-plated on the molded part (MID/antenna).—1301.590 Shore D
Lubricated / wear grade
Bearing and sliding-contact version with reduced friction and wear rate at high PV and high temperature.—1301.885 Shore D
ESD / conductive
Static-dissipative to conductive LCP for semiconductor handling trays, test sockets and EMI-relevant hardware.—1501.789 Shore D
E130iThis page
High-heat E-series, 30% glass, lead-free reflow
Higher-melting E-series chemistry for 260–290 °C lead-free reflow with low blistering and very low outgassing.—1602—
50% glass-fiber reinforced
Maximum stiffness/HDT and lowest CTE for structural or coplanarity-critical parts; flow and toughness drop noticeably.—1701.5—
15% glass-fiber reinforced
Light glass loading when you need better dimensional balance and stiffness but must keep thin-wall flow close to unfilled.—1752.890 Shore D
A950Default
Unfilled natural A-series LCP
Base unfilled HBA/HNA resin — pick for maximum flow, thinnest walls, best chemical/dielectric purity and self-reinforced anisotropic strength.—1823.4—
30% glass-fiber reinforced
The default choice for SMT connectors and reflow-exposed housings: high modulus, 230 °C HDT, controlled warpage.—1852.4—
30% carbon-fiber reinforced
Highest specific stiffness plus static-dissipative surface and low wear — pick for precision fixtures, wafer handling and ESD-sensitive parts.—2001.4—

What is Vectra E130i?

Vectra E130i is Vectra in the E130i grade — higher-melting E-series chemistry for 260–290 °C lead-free reflow with low blistering and very low outgassing. Vectra E130i has a tensile strength of 160 MPa (23.2 ksi), stronger than 96% of polymer grades. Elongation at break is 2% and the elastic modulus is 15 GPa (2.18 Msi). Vectra E130i has a density of 1.62 g/cm³ (0.0585 lb/in³), heavier than 94% of polymer grades. Its glass-transition temperature is 110°C (230 °F). A950 is the default condition FabDigit quotes; E130i is available on request or by drawing note.

Advantages

  • Stiff — 15 GPa (2.18 Msi), better than 99% of polymer grades
  • Low, predictable mold shrinkage — 0.2%, better than 94% of polymer grades
  • High service temperature — 240°C (464 °F), better than 92% of polymer grades
  • Low moisture uptake — 0.03%, better than 88% of polymer grades
  • Good corrosion resistance — 90/100, better than 82% of polymer grades

Limitations

  • Limited ductility — 2%, worse than 95% of polymer grades
  • Heavy — 1.62 g/cm³ (0.0585 lb/in³), worse than 94% of polymer grades
  • Limited formability — 10/100, worse than 87% of polymer grades
  • High embodied carbon — 8.5 kg CO₂/kg, worse than 85% of polymer grades

Vectra E130i properties

Typical room-temperature values for Vectra E130i; 11 are specific to this condition. Other listed values are Vectra reference data and may not represent this condition. Bars are the position among polymer grades.

Physical5

Vectra E130i has a density of 1.62 g/cm³ (0.0585 lb/in³), heavier than 94% of polymer grades. Its glass-transition temperature is 110°C (230 °F).

Density1.62 g/cm³0.06 lb/in³
Melting Temperature (Tm)335°C635 °F
Glass Transition (Tg)110°C230 °F
Water Absorption (24 h)0.03%
Water Absorption (Saturation)0.1%

Mechanical9

Vectra E130i has a tensile strength of 160 MPa (23.2 ksi), stronger than 96% of polymer grades. Elongation at break is 2% and the elastic modulus is 15 GPa (2.18 Msi).

Elastic (Young's) Modulus15 GPa2.2 Msi
Poisson's Ratio0.35
Tensile Strength (Ultimate)160 MPa23.2 ksi
Elongation at Break2%
Flexural Strength158 MPa22.9 ksi
Flexural Modulus14.5 GPa2.1 Msi
Izod Impact, Notched500 J/m9.4 ft·lbf/in
Hardness, Shore D88 Shore D
Hardness, Rockwell M70 HRM

Thermal10

Vectra E130i is rated for continuous service to 240°C (464 °F). It conducts heat at 0.25 W/m·K (0.144 BTU/hr·ft·°F), better than 72% of polymer grades. Thermal expansion is 5 µm/m·K (2.78 µin/in·°F).

Thermal Conductivity0.25 W/m·K0.14 BTU/hr·ft·°F
Specific Heat Capacity1,200 J/kg·K0.29 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)5 µm/m·K2.8 µin/in·°F
Max Service Temperature (continuous)240°C464 °F
Min Service Temperature-50°C-58 °F
Heat Deflection Temp. @ 0.45 MPa240°C464 °F
Heat Deflection Temp. @ 1.8 MPa270°C518 °F
Flammability (UL 94)V-0 at 0.4 mm
Limiting Oxygen Index35%
Max Service Temperature (short-term)290°C554 °F

Electrical7

Vectra E130i is an electrical insulator with a dielectric strength of 35 kV/mm (889 V/mil) and a resistivity of 1×10¹³ Ω·m.

Electrical Resistivity1×10¹³ Ω·m3.94×10²⁰ µΩ·in
Dielectric Strength35 kV/mm889 V/mil
Dielectric Constant (1 MHz)3.3
Dissipation Factor (1 MHz)0.005
Volume Resistivity1×10¹⁵ Ω·cm
Surface Resistivity1×10¹⁵ Ω
Comparative Tracking Index (CTI)200 V

Chemical & Environmental3

Corrosion resistance is excellent (90/100), better than 82% of polymer grades. UV resistance is fair.

Corrosion ResistanceExcellent90/100
UV / Weathering ResistanceFair40/100
Chemical Resistance SummaryOutstanding against acids, hydrocarbons, solvents, oils, alcohols and hydrolysis (steam/boiling water); essentially insoluble at room temperature. Attacked by hot concentrated caustic/strong bases and by hot chlorinated-phenol type solvents; long-term high-pH steam causes surface hydrolysis.

Sustainability3

Producing a kilogram of Vectra E130i takes about 180 MJ of energy and emits 8.5 kg of CO₂ — more than 87% of polymer grades. Typical recycled content is 0%.

Embodied Energy (primary production)180 MJ/kg77,386 BTU/lb
Embodied Carbon (primary production)8.5 kg CO₂/kg
Typical Recycled Content0%

Manufacturability7

Vectra E130i's machinability is good (55/100, worse than 64% of polymer grades); weldability poor (25/100); formability not recommended (10/100).

MachinabilityGood55/100
WeldabilityPoor25/100
Formability (cold)Not recommended10/100
PolishabilityFair40/100
Mold Shrinkage0.2%
Processing Melt Temperature (typ.)350°C662 °F
Mold Temperature (typ.)90°C194 °F

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with Vectra E130i

Is Vectra easy to machine?

Machinable with sharp carbide/PCD tools and high speed, low feed, but the fibrillar skin tends to fuzz and delaminate at edges; avoid deep interrupted cuts and support thin webs.

Can Vectra be welded?

Solvent and ultrasonic welding are unreliable because of the anisotropic skin; use laser transmission welding, heat staking, insert molding or mechanical/adhesive joints (surface pretreatment required for bonding).

Can Vectra be formed, bent or molded?

Inject at 285–330 °C (E-series to ~350 °C) with 40–130 °C molds, small gates and very high injection speed; dry 4 h at 150 °C, place gates to steer flow because weld lines retain only ~20–40 % of flow-direction strength.

What surface finishes work on Vectra?

Molded surfaces reproduce the tool finish well; can be laser-marked, vacuum-metallized or (with LDS grades) laser-activated and electrolessly copper/nickel/gold plated — painting needs plasma or primer pretreatment.

Vectra chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
4-hydroxybenzoic acid (HBA) unitA-series copolyester backbone70 – 7573
glass fiber0 for unfilled A950; 15/30/40/50 % in reinforced grades0 – 500
carbon fiberA230-type grades0 – 300
mineral filler (talc/wollastonite)low-warpage grades0 – 400
6-hydroxy-2-naphthoic acid (HNA) unitbalance of A-series backbone≥ 25 (balance)—

Vectra E130i — frequently asked

What is Vectra E130i used for?

Vectra E130i is typically used for SMT connectors, camera module housings, micro-precision gears and RF/antenna components. In short: industry reference LCP resin; high-flow thin-wall molding; LDS-platable grades available.

What is the tensile strength of Vectra E130i?

Vectra E130i has a typical tensile strength of 160 MPa (23.2 ksi) — stronger than 96% of polymer grades. Strength varies by condition: see the 10 listed tempers.

Is Vectra E130i easy to machine?

Reasonably — machinability is rated good (55/100, worse than 64% of polymer grades). Machinable with sharp carbide/PCD tools and high speed, low feed, but the fibrillar skin tends to fuzz and delaminate at edges; avoid deep interrupted cuts and support thin webs.

Can Vectra E130i be welded?

Not readily — weldability is rated poor (25/100). Solvent and ultrasonic welding are unreliable because of the anisotropic skin; use laser transmission welding, heat staking, insert molding or mechanical/adhesive joints (surface pretreatment required for bonding).

What surface finishes work on Vectra E130i?

Molded surfaces reproduce the tool finish well; can be laser-marked, vacuum-metallized or (with LDS grades) laser-activated and electrolessly copper/nickel/gold plated — painting needs plasma or primer pretreatment.

Can Vectra E130i be formed, bent or molded?

Inject at 285–330 °C (E-series to ~350 °C) with 40–130 °C molds, small gates and very high injection speed; dry 4 h at 150 °C, place gates to steer flow because weld lines retain only ~20–40 % of flow-direction strength.

What is the maximum service temperature of Vectra E130i?

Vectra E130i is rated for continuous use to about 240°C (464 °F), and briefly to 290°C. Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

Sources

  1. Vectra Liquid Crystal Polymer (LCP) product and processing brochure — Celanese (2023)
  2. CAMPUS plastics data for Vectra A950 / A130 / E130i — CAMPUS / Celanese (2023)
  3. ISO 527, ISO 178, ISO 75, ISO 180 test methods — ISO (2019)
  4. UL 94 Tests for Flammability of Plastic Materials — UL (2020)
  5. Engineering Plastics — Engineered Materials Handbook Vol. 2 (LCP chapter) — ASM International (1988)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.