FabDigitFabDigit

LCP Type II GF-MIN

Reinforced grade

ASTM D6779 · ISO LCP

GF-MIN = glass/mineral filled

Pick when flatness, blister-free reflow and clean laser marking on small SMT parts outrank peak strength.

High cost $$$$

Values for the GF-MIN condition

Other LCP Type II grades and fills

LCP Type II is listed in 10 conditions; see the grade overview at LCP Type II.

Compare all 10 grades and fillsHide
Grade · open for datasheetBest forYield MPaTensile MPaElong. %Hardness
Lubricated bearing grade
For unlubricated bushings, thrust washers and pump vanes running hot and dry against metal.—1101.888 Shore D
GF-MINThis page
Glass/mineral filled
Pick when flatness, blister-free reflow and clean laser marking on small SMT parts outrank peak strength.—1151.8—
Laser-direct-structuring (LDS) grade
Contains a laser-activatable metal-oxide additive so antenna traces can be plated directly on the molded 3D part.—1251.690 Shore D
Static-dissipative / conductive grade
Carbon-black or carbon-fiber loaded LCP for IC test sockets, burn-in hardware and semiconductor tooling needing controlled surface resistance.—1301.890 Shore D
30 % glass-fiber reinforced
The workhorse SMT-connector grade: best balance of stiffness, HDT above lead-free reflow, and dimensional stability.—1402.1—
Heat-stabilized / high-heat blow-off resistant grade
Formulated for repeated lead-free reflow (260 °C peak) and long-term 240 °C oven exposure without blistering.—1402.290 Shore D
40 % glass-fiber reinforced
Maximum stiffness/HDT and lowest CTE for coil bobbins, pump and sensor bodies where flow length is short.—1501.7—
15 % glass-fiber reinforced
Light reinforcement to cut anisotropy and warpage while keeping good flow for 0.3–0.5 mm connector walls.—1602.6—
High-frequency / low-loss grade
Low-Dk/Df formulations (often unfilled or spherical-filler modified) for antenna carriers, mmWave connectors and LCP film substrates.—1752.587 Shore D
30 % carbon-fiber reinforced
Highest specific stiffness plus static-dissipative/conductive behaviour and improved heat transfer for wafer-handling and precision parts.—1901.3—

What is LCP Type II GF-MIN?

LCP Type II GF-MIN is LCP Type II in the GF-MIN grade — pick when flatness, blister-free reflow and clean laser marking on small SMT parts outrank peak strength. LCP Type II GF-MIN has a tensile strength of 115 MPa (16.7 ksi), stronger than 92% of polymer grades. Elongation at break is 1.8% and the elastic modulus is 14 GPa (2.03 Msi). LCP Type II GF-MIN has a density of 1.7 g/cm³ (0.0614 lb/in³), heavier than 95% of polymer grades. Its glass-transition temperature is 110°C (230 °F).

Advantages

  • Stiff — 14 GPa (2.03 Msi), better than 98% of polymer grades
  • Low, predictable mold shrinkage — 0.2%, better than 94% of polymer grades
  • Low moisture uptake — 0.02%, better than 92% of polymer grades
  • High service temperature — 200°C (392 °F), better than 87% of polymer grades
  • Conducts heat well — 0.3 W/m·K (0.173 BTU/hr·ft·°F), better than 83% of polymer grades

Limitations

  • Limited ductility — 1.8%, worse than 97% of polymer grades
  • Heavy — 1.7 g/cm³ (0.0614 lb/in³), worse than 95% of polymer grades
  • High embodied carbon — 12 kg CO₂/kg, worse than 91% of polymer grades
  • Difficult to machine — 40/100, worse than 82% of polymer grades
  • Limited formability — 15/100, worse than 79% of polymer grades

LCP Type II GF-MIN properties

Typical room-temperature values for LCP Type II GF-MIN; 11 are specific to this condition. Other listed values are LCP Type II reference data and may not represent this condition. Bars are the position among polymer grades.

Physical5

LCP Type II GF-MIN has a density of 1.7 g/cm³ (0.0614 lb/in³), heavier than 95% of polymer grades. Its glass-transition temperature is 110°C (230 °F).

Density1.7 g/cm³0.06 lb/in³
Melting Temperature (Tm)280°C536 °F
Glass Transition (Tg)110°C230 °F
Water Absorption (24 h)0.02%
Water Absorption (Saturation)0.1%

Mechanical12

LCP Type II GF-MIN has a tensile strength of 115 MPa (16.7 ksi), stronger than 92% of polymer grades. Elongation at break is 1.8% and the elastic modulus is 14 GPa (2.03 Msi).

Elastic (Young's) Modulus14 GPa2 Msi
Shear Modulus1.5 GPa0.22 Msi
Poisson's Ratio0.4
Tensile Strength (Ultimate)115 MPa16.7 ksi
Elongation at Break1.8%
Compressive Strength70 MPa10.2 ksi
Flexural Strength155 MPa22.5 ksi
Flexural Modulus13 GPa1.9 Msi
Shear Strength45 MPa6.5 ksi
Izod Impact, Notched70 J/m1.3 ft·lbf/in
Hardness, Shore D87 Shore D
Hardness, Rockwell M85 HRM

Thermal10

LCP Type II GF-MIN is rated for continuous service to 200°C (392 °F). It conducts heat at 0.3 W/m·K (0.173 BTU/hr·ft·°F), better than 83% of polymer grades. Thermal expansion is 18 µm/m·K (10 µin/in·°F).

Thermal Conductivity0.3 W/m·K0.17 BTU/hr·ft·°F
Specific Heat Capacity1,200 J/kg·K0.29 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)18 µm/m·K10 µin/in·°F
Max Service Temperature (continuous)200°C392 °F
Min Service Temperature-100°C-148 °F
Heat Deflection Temp. @ 0.45 MPa230°C446 °F
Heat Deflection Temp. @ 1.8 MPa235°C455 °F
Flammability (UL 94)V-0 inherently at ≥0.4 mm without flame retardant additives; 5VA achievable on some grades
Limiting Oxygen Index38%
Max Service Temperature (short-term)260°C500 °F

Electrical7

LCP Type II GF-MIN is an electrical insulator with a dielectric strength of 35 kV/mm (889 V/mil) and a resistivity of 1×10¹³ Ω·m.

Electrical Resistivity1×10¹³ Ω·m3.94×10²⁰ µΩ·in
Dielectric Strength35 kV/mm889 V/mil
Dielectric Constant (1 MHz)3.4
Dissipation Factor (1 MHz)0.008
Volume Resistivity1×10¹⁵ Ω·cm
Surface Resistivity1×10¹⁵ Ω
Comparative Tracking Index (CTI)200 V

Chemical & Environmental3

Corrosion resistance is excellent (90/100), better than 82% of polymer grades. UV resistance is fair.

Corrosion ResistanceExcellent90/100
UV / Weathering ResistanceFair40/100
Chemical Resistance SummaryExcellent against acids, hydrocarbons, solvents, fuels, oils, hydrolysis and steam up to ~150 °C; attacked by hot concentrated caustic and hot strong alkalis, and degraded by prolonged UV exposure.

Sustainability4

Producing a kilogram of LCP Type II GF-MIN takes about 250 MJ of energy and emits 12 kg of CO₂ — more than 92% of polymer grades. Typical recycled content is 0%.

Embodied Energy (primary production)250 MJ/kg107,481 BTU/lb
Embodied Carbon (primary production)12 kg CO₂/kg
Embodied Water400 L/kg47.9 gal/lb
Typical Recycled Content0%

Manufacturability7

LCP Type II GF-MIN's machinability is fair (40/100, worse than 82% of polymer grades); weldability poor (25/100); formability poor (15/100).

MachinabilityFair40/100
WeldabilityPoor25/100
Formability (cold)Poor15/100
PolishabilityFair40/100
Mold Shrinkage0.2%
Processing Melt Temperature (typ.)310°C590 °F
Mold Temperature (typ.)100°C212 °F

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with LCP Type II GF-MIN

Is LCP Type II easy to machine?

Machines cleanly with sharp polished carbide/diamond tooling and light feeds, but the skin-core fibrillar structure delaminates and frays — avoid deep single-point cuts and drilling near thin walls.

Can LCP Type II be welded?

Poor for ultrasonic/vibration welding because the oriented skin splits; join by snap fit, press fit, insert molding, over-molding or laser welding on filled/absorbing grades; adhesives need plasma or corona pretreatment.

Can LCP Type II be formed, bent or molded?

Dry 4 h at 150 °C, melt 290–330 °C, mold 60–120 °C, use small gates, very high injection speed and short shots per cavity balance; expect near-zero flow shrinkage but 3–5× higher transverse shrinkage and weak weld lines — design gates to avoid knit lines in loaded areas.

What surface finishes work on LCP Type II?

Not paintable without primer; laser marks well on mineral/pigmented grades, plates directly only on LDS grades, and colors are limited by the high melt temperature (use high-heat pigments).

LCP Type II chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
4-hydroxybenzoic acid (HBA)mol % of aromatic ester units (Vectra A-type chemistry)60 – 8073
6-hydroxy-2-naphthoic acid (HNA)mol %; kinked comonomer that lowers Tm vs Type I20 – 4027
terephthalic acid / 4,4'-biphenol / aminused in Zenite/Sumika-type Type II copolyesters and copolyesteramides0 – 30—
glass fiberwt % in reinforced grades (GF15/GF30/GF40)0 – 500
mineral / talc / carbon fillerwt % in low-warpage, wear or ESD grades0 – 400

LCP Type II GF-MIN — frequently asked

What is LCP Type II GF-MIN used for?

LCP Type II GF-MIN is typically used for connectors and sockets, camera/optical housings, thin-wall precision parts and chemical-resistant seals. In short: most-used commercial LCP; lower melt than Type I; strongest LCP tensile class.

What is the tensile strength of LCP Type II GF-MIN?

LCP Type II GF-MIN has a typical tensile strength of 115 MPa (16.7 ksi) — stronger than 92% of polymer grades. Strength varies by condition: see the 10 listed tempers.

Is LCP Type II GF-MIN easy to machine?

Not especially — machinability is rated fair (40/100, worse than 82% of polymer grades). Machines cleanly with sharp polished carbide/diamond tooling and light feeds, but the skin-core fibrillar structure delaminates and frays — avoid deep single-point cuts and drilling near thin walls.

Can LCP Type II GF-MIN be welded?

Not readily — weldability is rated poor (25/100). Poor for ultrasonic/vibration welding because the oriented skin splits; join by snap fit, press fit, insert molding, over-molding or laser welding on filled/absorbing grades; adhesives need plasma or corona pretreatment.

What surface finishes work on LCP Type II GF-MIN?

Not paintable without primer; laser marks well on mineral/pigmented grades, plates directly only on LDS grades, and colors are limited by the high melt temperature (use high-heat pigments).

Can LCP Type II GF-MIN be formed, bent or molded?

Dry 4 h at 150 °C, melt 290–330 °C, mold 60–120 °C, use small gates, very high injection speed and short shots per cavity balance; expect near-zero flow shrinkage but 3–5× higher transverse shrinkage and weak weld lines — design gates to avoid knit lines in loaded areas.

What is the maximum service temperature of LCP Type II GF-MIN?

LCP Type II GF-MIN is rated for continuous use to about 200°C (392 °F), and briefly to 260°C. Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

Sources

  1. ASTM D6779 Standard Classification System for Liquid Crystal Polymers (LCP) Molding and Extrusion Materials — ASTM International (2022)
  2. Vectra LCP product and processing guide (A950, A130, A430, A230 grades) — Celanese (2023)
  3. Zenite LCP resin datasheets — Celanese (formerly DuPont) (2022)
  4. Sumikasuper LCP technical data — Sumitomo Chemical (2023)
  5. CAMPUS / UL Prospector LCP material data sheets — CWFG / UL Solutions (2024)
  6. Engineered Materials Handbook Vol. 2: Engineering Plastics — ASM International (1988)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.