FabDigitFabDigit

LCP Type II vs Xydar

Polymer · grade comparison

LCP Type II and Xydar are both polymer grades. LCP Type II is the stronger of the two: tensile strength 180 MPa (26.1 ksi) against 130 MPa (18.9 ksi) for Xydar, about 38% more. LCP Type II is the more ductile: elongation 3.5% versus 2.5% for Xydar. Xydar is stiffer (12 GPa vs 10.5 GPa) and Xydar runs hotter in service (240°C vs 200°C continuous).

LCP Type IIChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

XydarChoose it when the part sees heat.

LCP Type II vs Xydar: properties

LCP Type IIXydar

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

10.5 GPa1.5 Msi
12 GPa1.7 Msi

Shear Modulus

1.5 GPa0.22 Msi
—

Poisson's Ratio

0.4
0.35

Tensile Strength (Ultimate)

180 MPa26.1 ksi
130 MPa18.9 ksi

Elongation at Break

3.5%
2.5%

Compressive Strength

70 MPa10.2 ksi
65 MPa9.4 ksi

Flexural Strength

160 MPa23.2 ksi
135 MPa19.6 ksi

Flexural Modulus

9 GPa1.3 Msi
11 GPa1.6 Msi

Shear Strength

45 MPa6.5 ksi
50 MPa7.3 ksi

Izod Impact, Notched

500 J/m9.4 ft·lbf/in
160 J/m3 ft·lbf/in

Hardness, Shore D

87 Shore D
88 Shore D

Hardness, Rockwell M

85 HRM
75 HRM

Fracture Toughness (K_IC)

—
2.5 MPa·√m2.3 ksi·√in

Physical

Density and transition temperatures.

Melting Temperature (Tm)

280°C536 °F
350°C662 °F

Glass Transition (Tg)

110°C230 °F
135°C275 °F

Water Absorption (24 h)

0.02%
0.03%

Same in both: Density 1.4 g/cm³0.05 lb/in³ · Water Absorption (Saturation) 0.1%

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

0.3 W/m·K0.17 BTU/hr·ft·°F
0.2 W/m·K0.12 BTU/hr·ft·°F

Specific Heat Capacity

1,200 J/kg·K0.29 BTU/lb·°F
1,150 J/kg·K0.27 BTU/lb·°F

Max Service Temperature (continuous)

200°C392 °F
240°C464 °F

Heat Deflection Temp. @ 0.45 MPa

230°C446 °F
300°C572 °F

Heat Deflection Temp. @ 1.8 MPa

185°C365 °F
240°C464 °F

Limiting Oxygen Index

38%
42%

Max Service Temperature (short-term)

260°C500 °F
300°C572 °F

Same in both: Thermal Expansion (CTE, 20–100 °C) 8 µm/m·K4.4 µin/in·°F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Dielectric Constant (1 MHz)

3.4
3.7

Dissipation Factor (1 MHz)

0.008
0.005

Same in both: Electrical Resistivity 1×10¹³ Ω·m3.94×10²⁰ µΩ·in · Dielectric Strength 35 kV/mm889 V/mil · Volume Resistivity 1×10¹⁵ Ω·cm · Surface Resistivity 1×10¹⁵ Ω · Comparative Tracking Index (CTI) 200 V

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

90 / 100
92 / 100

UV / Weathering Resistance

40 / 100
55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Formability (cold)

15 / 100
20 / 100

Mold Shrinkage

0.1%
0.15%

Processing Melt Temperature (typ.)

310°C590 °F
380°C716 °F

Mold Temperature (typ.)

100°C212 °F
120°C248 °F

Same in both: Machinability 55 / 100 · Weldability 25 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

250 MJ/kg107,481 BTU/lb
220 MJ/kg94,583 BTU/lb

Embodied Carbon (primary production)

12 kg CO₂/kg
10 kg CO₂/kg

Embodied Water

400 L/kg47.9 gal/lb
500 L/kg59.9 gal/lb

Same in both: Typical Recycled Content 0%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

129 kN·m/kg
93 kN·m/kg

Specific Stiffness (E / density)

7.5 MN·m/kg
8.6 MN·m/kg

Thermal Diffusivity

0.2 mm²/s
0.1 mm²/s

Thermal Shock Resistance Index

1
0

Strength versus weight

Yield strength against density for every polymer grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

0.1110100123Density (g/cm³)Yield strength (MPa) — log scale

Manufacturing and finishing

CapabilityLCP Type IIXydar
Default condition——
Relative cost$$$$ High$$$$ High
Min. machined wall——
Best machined surface——

LCP Type II vs Xydar — frequently asked

Is LCP Type II stronger than Xydar?

Yes. LCP Type II has a typical tensile strength of 180 MPa (26.1 ksi) against 130 MPa (18.9 ksi) for Xydar — about 38% more.

Which is cheaper, LCP Type II or Xydar?

Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.

When should I choose LCP Type II over Xydar?

Pick LCP Type II when strength drives the design, or when the part is bent, formed or impact-loaded. Pick Xydar when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in LCP Type II and Xydar side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.