Standard cost $$

Values for the Magnetic Anneal condition

Other Ingot Iron tempers and conditions

Ingot Iron is listed in 6 conditions; see the grade overview at Ingot Iron.

Compare all 6 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
Magnetic AnnealThis page
850–950 °C, controlled slow cool
Choose for finished electromagnet cores and relay parts needing lowest coercivity and highest permeability after machining.1302604865 HB17.6 % IACS
AnnealedDefault
full anneal ~850–900 °C, slow cool
Standard stocked condition for magnetic cores, poles and deep-drawn parts; softest mechanically with good permeability.1502754570 HB78 W/m·K
~900 °C, air cool
Uniform fine-grained structure for heavier sections where a full magnetic anneal is not required.1702954080 HB17.3 % IACS
as-rolled plate, bar and coil
Lowest-cost mill condition for weldments and parts that will be annealed after fabrication.1853103585 HB17.2 % IACS
Cold Drawn / cold rolled ~1/4–1/2 hard
Pick for straight, close-tolerance bar and shafts where higher strength and better surface finish matter more than magnetic quality.32038015110 HB74 W/m·K
heavily cold rolled strip/wire
Only for stiff springy strip, wire and shims; magnetic softness is lost and ductility is minimal.4104606135 HB16.8 % IACS

What is Ingot Iron Magnetic Anneal?

Ingot Iron Magnetic Anneal is Ingot Iron heat treated to Magnetic Anneal — choose for finished electromagnet cores and relay parts needing lowest coercivity and highest permeability after machining. Ingot Iron Magnetic Anneal has a yield strength of 130 MPa (18.9 ksi) and a tensile strength of 260 MPa (37.7 ksi) — weaker than 100% of steel grades. Elongation at break is 48% and the elastic modulus is 205 GPa (29.7 Msi). Ingot Iron Magnetic Anneal has a density of 7.87 g/cm³ (0.284 lb/in³), heavier than 92% of steel grades. It melts at 1,535°C (2,795 °F). Annealed is the default condition FabDigit quotes; Magnetic Anneal is available on request or by drawing note.

Advantages

  • Ductile — tolerates forming and impact — 48%, better than 100% of steel grades
  • Conducts heat well — 80 W/m·K (46.2 BTU/hr·ft·°F), better than 100% of steel grades
  • High electrical conductivity — 17.6 % IACS, better than 100% of steel grades
  • Forms and bends easily — 98/100, better than 100% of steel grades
  • Readily welded — 95/100, better than 97% of steel grades

Limitations

  • Low strength — 130 MPa (18.9 ksi), worse than 100% of steel grades
  • Difficult to machine — 40/100, worse than 77% of steel grades

Ingot Iron Magnetic Anneal properties

Typical room-temperature values for Ingot Iron Magnetic Anneal; 23 are specific to this condition. Other listed values are Ingot Iron reference data and may not represent this condition. Bars are the position among steel grades.

Physical3

Ingot Iron Magnetic Anneal has a density of 7.87 g/cm³ (0.284 lb/in³), heavier than 92% of steel grades. It melts at 1,535°C (2,795 °F).

Density7.87 g/cm³0.28 lb/in³
Melting Point (Solidus)1,535°C2,795 °F
Liquidus Temperature1,538°C2,800 °F

Mechanical16

Ingot Iron Magnetic Anneal has a yield strength of 130 MPa (18.9 ksi) and a tensile strength of 260 MPa (37.7 ksi) — weaker than 100% of steel grades. Elongation at break is 48% and the elastic modulus is 205 GPa (29.7 Msi).

Elastic (Young's) Modulus205 GPa29.7 Msi
Shear Modulus80 GPa11.6 Msi
Bulk Modulus170 GPa24.7 Msi
Poisson's Ratio0.29
Tensile Strength (Ultimate)260 MPa37.7 ksi
Yield Strength (0.2% offset)130 MPa18.9 ksi
Elongation at Break48%
Reduction in Area75%
Compressive Strength130 MPa18.9 ksi
Shear Strength180 MPa26.1 ksi
Fatigue Strength (Endurance Limit)155 MPa22.5 ksi
Fracture Toughness (K_IC)140 MPa·√m127 ksi·√in
Charpy V-Notch Impact (RT)220 J162 ft·lbf
Hardness, Brinell65 HB
Hardness, Rockwell B22 HRB
Hardness, Vickers68 HV

Thermal6

Ingot Iron Magnetic Anneal is rated for continuous service to 450°C (842 °F). It conducts heat at 80 W/m·K (46.2 BTU/hr·ft·°F), better than 100% of steel grades. Thermal expansion is 12 µm/m·K (6.67 µin/in·°F).

Thermal Conductivity80 W/m·K46.2 BTU/hr·ft·°F
Specific Heat Capacity455 J/kg·K0.11 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)12 µm/m·K6.7 µin/in·°F
Latent Heat of Fusion247 J/g106 BTU/lb
Max Service Temperature (continuous)450°C842 °F
Min Service Temperature-50°C-58 °F

Electrical3

Ingot Iron Magnetic Anneal conducts electricity at 17.6 % IACS, better than 100% of steel grades.

Electrical Conductivity17.6 % IACS
Electrical Resistivity9.8×10⁻⁸ Ω·m3.86 µΩ·in
Magnetic Responseferromagnetic — coercivity as low as 24–48 A/m (DT4E/DT4C), max relative permeability 6000–12000, Bs ≈ 2.15 T

Chemical & Environmental3

Corrosion resistance is not recommended (10/100), worse than 86% of steel grades.

Galvanic Potential (seawater, vs SCE)-0.62 V
Corrosion ResistanceNot recommended10/100
Chemical Resistance SummaryRusts readily in humid air and water; attacked by all dilute acids and chlorides; stable in dry air, strong alkalis and concrete environments; requires plating, phosphating, oiling or paint for storage and service.

Sustainability4

Producing a kilogram of Ingot Iron Magnetic Anneal takes about 28 MJ of energy and emits 2.1 kg of CO₂ — less than 56% of steel grades. Typical recycled content is 15%.

Embodied Energy (primary production)28 MJ/kg12,038 BTU/lb
Embodied Carbon (primary production)2.1 kg CO₂/kg
Embodied Water40 L/kg4.8 gal/lb
Typical Recycled Content15%

Manufacturability8

Ingot Iron Magnetic Anneal's machinability is fair (40/100, worse than 77% of steel grades); weldability excellent (95/100); formability excellent (98/100).

MachinabilityFair40/100
Machinability Rating (AISI 1212 = 100 %)45%
WeldabilityExcellent95/100
Formability (cold)Excellent98/100
CastabilityFair35/100
Brazeability / SolderabilityExcellent85/100
PolishabilityGood60/100
Anodizing Responsen/a — ferrous material; use zinc/nickel plating, phosphating or paint instead

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with Ingot Iron Magnetic Anneal

Is Ingot Iron easy to machine?

Very gummy — use sharp positive-rake tools, high speed, generous coolant and light finishing passes to avoid built-up edge and tearing; chip breaking is poor.

Can Ingot Iron be welded?

Excellent by any process (GTAW, GMAW, resistance, EB); no preheat or PWHT needed for hardness, but re-anneal welded magnetic cores to restore permeability.

Can Ingot Iron be formed, bent or molded?

Outstanding cold formability — deep drawing, spinning, cold heading and severe bending all practical; expect low springback and stick-slip galling, so lubricate well.

What surface finishes work on Ingot Iron?

Rusts quickly bare: zinc/nickel plate, phosphate + oil, or paint; polishes to a bright but soft, easily scratched surface; not anodizable.

Ingot Iron chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
C≤0.010 % typical for hydrogen-annealed magnetic grades≤ 0.030.01
SiARMCO-type ingot iron typically <0.01 %≤ 0.30.02
Mn≤ 0.40.05
P≤ 0.020.01
S≤ 0.030.01
Alresidual from deoxidation≤ 0.10.02
Fe≥99.8 %, commonly 99.85–99.95 %balance—

Ingot Iron Magnetic Anneal — frequently asked

What is Ingot Iron Magnetic Anneal used for?

Ingot Iron Magnetic Anneal is typically used for magnetic pole pieces and cores, electromagnet cores, chemical/corrosion test coupons, enameling stock and welding electrode cores. In short: magnetically softest iron stock; best cold formability; lowest-carbon iron grade.

What is the yield strength of Ingot Iron Magnetic Anneal?

Ingot Iron Magnetic Anneal has a typical yield strength of 130 MPa (18.9 ksi) and a tensile strength of 260 MPa (37.7 ksi) — weaker than 100% of steel grades. Strength varies by condition: see the 6 listed tempers.

Is Ingot Iron Magnetic Anneal easy to machine?

Not especially — machinability is rated fair (40/100, worse than 77% of steel grades). Very gummy — use sharp positive-rake tools, high speed, generous coolant and light finishing passes to avoid built-up edge and tearing; chip breaking is poor.

Can Ingot Iron Magnetic Anneal be welded?

Yes — weldability is rated excellent (95/100). Excellent by any process (GTAW, GMAW, resistance, EB); no preheat or PWHT needed for hardness, but re-anneal welded magnetic cores to restore permeability.

What surface finishes work on Ingot Iron Magnetic Anneal?

Rusts quickly bare: zinc/nickel plate, phosphate + oil, or paint; polishes to a bright but soft, easily scratched surface; not anodizable.

Can Ingot Iron Magnetic Anneal be formed, bent or molded?

Outstanding cold formability — deep drawing, spinning, cold heading and severe bending all practical; expect low springback and stick-slip galling, so lubricate well.

What is the maximum service temperature of Ingot Iron Magnetic Anneal?

Ingot Iron Magnetic Anneal is rated for continuous use to about 450°C (842 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

Sources

  1. GB/T 6983 — SAC (2008)
  2. ASTM A848 Standard Specification for Low-Carbon Magnetic Iron — ASTM (2016)
  3. ASM Handbook Vol.1 — Properties and Selection: Irons, Steels, and High-Performance Alloys — ASM International (1990)
  4. ASM Handbook Vol.13A — Corrosion: Fundamentals, Testing, and Protection — ASM International (2003)
  5. ASM Metals Reference Book, 3rd ed. — ASM International (1993)
  6. Commercially pure / magnetic iron bar and strip datasheets — AK Steel / Ed Fagan / · (2022)