FabDigitFabDigit

LCP Type III vs Xydar

Polymer · grade comparison

LCP Type III and Xydar are both polymer grades. LCP Type III is the stronger of the two: tensile strength 150 MPa (21.8 ksi) against 130 MPa (18.9 ksi) for Xydar, about 15% more. LCP Type III is the more ductile: elongation 3% versus 2.5% for Xydar. Xydar is stiffer (12 GPa vs 10 GPa) and Xydar runs hotter in service (240°C vs 170°C continuous).

LCP Type IIIChoose it when strength drives the design, or when the part is bent, formed or impact-loaded.

XydarChoose it when the part sees heat.

LCP Type III vs Xydar: properties

LCP Type IIIXydar

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

10 GPa1.5 Msi
12 GPa1.7 Msi

Shear Modulus

1.2 GPa0.17 Msi
—

Poisson's Ratio

0.36
0.35

Tensile Strength (Ultimate)

150 MPa21.8 ksi
130 MPa18.9 ksi

Elongation at Break

3%
2.5%

Flexural Strength

140 MPa20.3 ksi
135 MPa19.6 ksi

Flexural Modulus

9 GPa1.3 Msi
11 GPa1.6 Msi

Shear Strength

55 MPa8 ksi
50 MPa7.3 ksi

Izod Impact, Notched

200 J/m3.7 ft·lbf/in
160 J/m3 ft·lbf/in

Hardness, Rockwell M

72 HRM
75 HRM

Fracture Toughness (K_IC)

—
2.5 MPa·√m2.3 ksi·√in

Same in both: Compressive Strength 65 MPa9.4 ksi · Hardness, Shore D 88 Shore D

Physical

Density and transition temperatures.

Melting Temperature (Tm)

285°C545 °F
350°C662 °F

Glass Transition (Tg)

105°C221 °F
135°C275 °F

Water Absorption (24 h)

0.02%
0.03%

Water Absorption (Saturation)

0.06%
0.1%

Same in both: Density 1.4 g/cm³0.05 lb/in³

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

0.3 W/m·K0.17 BTU/hr·ft·°F
0.2 W/m·K0.12 BTU/hr·ft·°F

Specific Heat Capacity

1,200 J/kg·K0.29 BTU/lb·°F
1,150 J/kg·K0.27 BTU/lb·°F

Max Service Temperature (continuous)

170°C338 °F
240°C464 °F

Min Service Temperature

-50°C-58 °F
-100°C-148 °F

Heat Deflection Temp. @ 0.45 MPa

225°C437 °F
300°C572 °F

Heat Deflection Temp. @ 1.8 MPa

185°C365 °F
240°C464 °F

Limiting Oxygen Index

38%
42%

Max Service Temperature (short-term)

230°C446 °F
300°C572 °F

Same in both: Thermal Expansion (CTE, 20–100 °C) 8 µm/m·K4.4 µin/in·°F

Electrical

Conductivity and insulation.

Dielectric Constant (1 MHz)

3.4
3.7

Dissipation Factor (1 MHz)

0.004
0.005

Same in both: Electrical Resistivity 1×10¹³ Ω·m3.94×10²⁰ µΩ·in · Dielectric Strength 35 kV/mm889 V/mil · Volume Resistivity 1×10¹⁵ Ω·cm · Surface Resistivity 1×10¹⁵ Ω · Comparative Tracking Index (CTI) 200 V

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

UV / Weathering Resistance

45 / 100
55 / 100

Same in both: Corrosion Resistance 92 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Weldability

30 / 100
25 / 100

Melt Flow Rate

40 g/10 min
—

Processing Melt Temperature (typ.)

310°C590 °F
380°C716 °F

Mold Temperature (typ.)

90°C194 °F
120°C248 °F

Same in both: Machinability 55 / 100 · Formability (cold) 20 / 100 · Polishability 40 / 100 · Mold Shrinkage 0.15%

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

180 MJ/kg77,386 BTU/lb
220 MJ/kg94,583 BTU/lb

Embodied Carbon (primary production)

8.5 kg CO₂/kg
10 kg CO₂/kg

Embodied Water

300 L/kg35.9 gal/lb
500 L/kg59.9 gal/lb

Same in both: Typical Recycled Content 0%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

107 kN·m/kg
93 kN·m/kg

Specific Stiffness (E / density)

7.1 MN·m/kg
8.6 MN·m/kg

Thermal Diffusivity

0.2 mm²/s
0.1 mm²/s

Thermal Shock Resistance Index

1
0

Strength versus weight

Yield strength against density for every polymer grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

0.1110100123Density (g/cm³)Yield strength (MPa) — log scale

Manufacturing and finishing

CapabilityLCP Type IIIXydar
Default condition——
Relative cost$$$$ High$$$$ High
Min. machined wall——
Best machined surface——

LCP Type III vs Xydar — frequently asked

Is LCP Type III stronger than Xydar?

Yes. LCP Type III has a typical tensile strength of 150 MPa (21.8 ksi) against 130 MPa (18.9 ksi) for Xydar — about 15% more.

Which is cheaper, LCP Type III or Xydar?

Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which welds better, LCP Type III or Xydar?

LCP Type III. Its weldability rates poor (30/100) against poor (25/100) for Xydar.

Ready to make it?

Upload a CAD file and FabDigit prices the part in LCP Type III and Xydar side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.