FabDigitFabDigit

GB/T 10801.1 Type II FR-B1

Flame-retardant grade

FR-B1 = flame retardant, GB 8624 B1(B) grade

Choose this flame-retardant grade with oxygen index of at least 30% when a thin-render external wall insulation system requires the GB 8624 B1(B) class; service limit is 75 °C.

Standard cost $$

Values for the FR-B1 condition

Other GB/T 10801.1 Type II grades and fills

GB/T 10801.1 Type II is listed in 6 conditions; see the grade overview at GB/T 10801.1 Type II.

Compare all 6 grades and fillsHide
Grade · open for datasheetBest forYield MPaTensile MPaElong. %Hardness
Nominal 20 kg/m³
Use the 20 kg/m³ economy density that just meets the class limit for wall insulation and lightly loaded fill; strength and stiffness are the lowest in the range.—0.226.5—
FR-B1This page
Flame retardant, GB 8624 B1(B) grade
Choose this flame-retardant grade with oxygen index of at least 30% when a thin-render external wall insulation system requires the GB 8624 B1(B) class; service limit is 75 °C.—0.246—
Graphite-enhanced EPS (grey SEPS)
Choose the grey graphite-filled foam when ultra-low-energy buildings demand 10-15% lower thermal conductivity at the same 21 kg/m³ density, at added material cost.—0.245.5—
Flame retardant, GB 8624 B2(C/D) grade
Pick the low-cost flame-retardant tier for locations with lower fire-class requirements, for packaging and for roof sandwich cores.—0.256—
Packaging / shape-moulded grade
Choose shape-moulded packaging parts when resilience and repeated impact energy absorption drive the design rather than long-term insulation performance.—0.257—
Nominal 25 kg/m³
Pick the 25 kg/m³ upper density when load capacity and dimensional stability matter, as in floor levelling layers, roof slope forming and heavy packaging.—0.36—

What is GB/T 10801.1 Type II FR-B1?

GB/T 10801.1 Type II FR-B1 is GB/T 10801.1 Type II in the FR-B1 grade — choose this flame-retardant grade with oxygen index of at least 30% when a thin-render external wall insulation system requires the GB 8624 B1(B) class; service limit is 75 °C. GB/T 10801.1 Type II FR-B1 has a tensile strength of 0.24 MPa (0.0348 ksi), weaker than 96% of polymer grades. Elongation at break is 6% and the elastic modulus is 0 GPa (6.53×10⁻⁴ Msi). GB/T 10801.1 Type II FR-B1 has a density of 0.02 g/cm³ (7.59×10⁻⁴ lb/in³), lighter than 97% of polymer grades. Its glass-transition temperature is 100°C (212 °F).

Advantages

  • Lightweight — 0.02 g/cm³ (7.59×10⁻⁴ lb/in³), better than 97% of polymer grades
  • Easy to machine — 90/100, better than 95% of polymer grades
  • Low, predictable mold shrinkage — 0.45%, better than 77% of polymer grades
  • Low embodied carbon — 3.4 kg CO₂/kg, better than 76% of polymer grades

Limitations

  • Low stiffness — 0 GPa (6.53×10⁻⁴ Msi), worse than 90% of polymer grades
  • Poor heat conductor — 0.04 W/m·K (0.0225 BTU/hr·ft·°F), worse than 88% of polymer grades
  • Degrades in UV without stabilisers — 20/100, worse than 88% of polymer grades

GB/T 10801.1 Type II FR-B1 properties

Typical room-temperature values for GB/T 10801.1 Type II FR-B1; 19 are specific to this condition. Other listed values are GB/T 10801.1 Type II reference data and may not represent this condition. Bars are the position among polymer grades.

Physical3

GB/T 10801.1 Type II FR-B1 has a density of 0.02 g/cm³ (7.59×10⁻⁴ lb/in³), lighter than 97% of polymer grades. Its glass-transition temperature is 100°C (212 °F).

Density0.02 g/cm³7.59×10⁻⁴ lb/in³
Glass Transition (Tg)100°C212 °F
Water Absorption (Saturation)3%

Mechanical8

GB/T 10801.1 Type II FR-B1 has a tensile strength of 0.24 MPa (0.0348 ksi), weaker than 96% of polymer grades. Elongation at break is 6% and the elastic modulus is 0 GPa (6.53×10⁻⁴ Msi).

Elastic (Young's) Modulus0 GPa6.53×10⁻⁴ Msi
Poisson's Ratio0.1
Tensile Strength (Ultimate)0.24 MPa0.03 ksi
Elongation at Break6%
Compressive Strength0.12 MPa0.02 ksi
Compressive Modulus0.01 GPa7.25×10⁻⁴ Msi
Flexural Strength0.28 MPa0.04 ksi
Shear Strength0.15 MPa0.02 ksi

Thermal9

GB/T 10801.1 Type II FR-B1 is rated for continuous service to 75°C (167 °F). It conducts heat at 0.04 W/m·K (0.0225 BTU/hr·ft·°F), worse than 88% of polymer grades. Thermal expansion is 65 µm/m·K (36.1 µin/in·°F).

Thermal Conductivity0.04 W/m·K0.02 BTU/hr·ft·°F
Specific Heat Capacity1,400 J/kg·K0.33 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)65 µm/m·K36.1 µin/in·°F
Max Service Temperature (continuous)75°C167 °F
Min Service Temperature-50°C-58 °F
Vicat Softening Point (B50)94°C201 °F
Flammability (UL 94)—
Limiting Oxygen Index32%
Max Service Temperature (short-term)85°C185 °F

Electrical2

Dielectric Constant (1 MHz)1.03
Volume Resistivity1×10¹⁵ Ω·cm

Chemical & Environmental3

Corrosion resistance is very good (74/100), worse than 68% of polymer grades. UV resistance is poor.

Corrosion ResistanceVery good74/100
UV / Weathering ResistancePoor20/100
Chemical Resistance Summary—

Sustainability4

Producing a kilogram of GB/T 10801.1 Type II FR-B1 takes about 100 MJ of energy and emits 3.4 kg of CO₂ — less than 61% of polymer grades. Typical recycled content is 5%.

Embodied Energy (primary production)100 MJ/kg42,992 BTU/lb
Embodied Carbon (primary production)3.4 kg CO₂/kg
Embodied Water180 L/kg21.6 gal/lb
Typical Recycled Content5%

Manufacturability5

GB/T 10801.1 Type II FR-B1's machinability is excellent (90/100, better than 95% of polymer grades); weldability poor (22/100); formability fair (40/100).

MachinabilityExcellent90/100
WeldabilityPoor22/100
Formability (cold)Fair40/100
Mold Shrinkage0.45%
Processing Melt Temperature (typ.)110°C230 °F

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with GB/T 10801.1 Type II FR-B1

Is GB/T 10801.1 Type II easy to machine?

Hot-wire cutting is best — smooth faces and no dust; band saws and utility knives also work. Avoid high-speed tooling that melts the cut face through friction.

Can GB/T 10801.1 Type II be welded?

Not fusion welded. Join sheets with a hot-air rod or dedicated EPS adhesives (polyurethane adhesive, cement-based bonding mortar); solvent-based adhesives dissolve the foam.

Can GB/T 10801.1 Type II be formed, bent or molded?

Pre-expansion, aging, then steam moulding at 0.05–0.12 MPa steam into large blocks, followed by hot-wire cutting into board. Moulding shrinkage is about 0.3–0.6%, so age blocks fully before cutting to stabilise dimensions.

What surface finishes work on GB/T 10801.1 Type II?

Face with crack-resistant mortar plus mesh cloth, or with a cement-based or coated finish. Do not leave exposed to UV and do not use solvent-based coatings.

GB/T 10801.1 Type II chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
pentane (blowing agent, residual)residual pentane after curing, decreases with ageing0.3 – 52
brominated flame retardant (polymeric FRpresent only in flame-retardant B1/B2 types0.3 – 1.20.7
nucleating agent / lubricant / antistati0.1 – 10.3
graphiteonly graphite-modified grey board contains 1–4%0 – 40
polystyrene (PS)expandable polystyrene bead matrix≥ 90 (balance)—

GB/T 10801.1 Type II FR-B1 — frequently asked

What is GB/T 10801.1 Type II FR-B1 used for?

GB/T 10801.1 Type II FR-B1 is typically used for EIFS wall insulation, roof insulation and cold storage insulation. In short: standard EIFS-grade EPS; graphite (grey) option available; stronger than Type I.

What is the tensile strength of GB/T 10801.1 Type II FR-B1?

GB/T 10801.1 Type II FR-B1 has a typical tensile strength of 0.24 MPa (0.0348 ksi) — weaker than 96% of polymer grades. Strength varies by condition: see the 6 listed tempers.

Is GB/T 10801.1 Type II FR-B1 easy to machine?

Yes — machinability is rated excellent (90/100, better than 95% of polymer grades). Hot-wire cutting is best — smooth faces and no dust; band saws and utility knives also work. Avoid high-speed tooling that melts the cut face through friction.

Can GB/T 10801.1 Type II FR-B1 be welded?

Not readily — weldability is rated poor (22/100). Not fusion welded. Join sheets with a hot-air rod or dedicated EPS adhesives (polyurethane adhesive, cement-based bonding mortar); solvent-based adhesives dissolve the foam.

What surface finishes work on GB/T 10801.1 Type II FR-B1?

Face with crack-resistant mortar plus mesh cloth, or with a cement-based or coated finish. Do not leave exposed to UV and do not use solvent-based coatings.

Can GB/T 10801.1 Type II FR-B1 be formed, bent or molded?

Pre-expansion, aging, then steam moulding at 0.05–0.12 MPa steam into large blocks, followed by hot-wire cutting into board. Moulding shrinkage is about 0.3–0.6%, so age blocks fully before cutting to stabilise dimensions.

What is the maximum service temperature of GB/T 10801.1 Type II FR-B1?

GB/T 10801.1 Type II FR-B1 is rated for continuous use to about 75°C (167 °F), and briefly to 85°C. Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

Sources

  1. Handbook of Polymeric Foams and Foam Technology — Hanser (2004)
  2. CES/ICE embodied energy & carbon data for EPS — Granta / University of Bath (2019)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.