FabDigitFabDigit

Copper Alloy ERCuSi-A SPOOL

Supply condition

UNS C65600 · GB HSCuSi

SPOOL = spooled solid MIG wire, hard-drawn

Product-form condition of the wire itself on a spool — cold-drawn, stiff enough for good feedability.

High cost $$$$

Values for the SPOOL condition

Other ERCuSi-A tempers and conditions

ERCuSi-A is listed in 2 conditions; see the grade overview at ERCuSi-A.

Compare all 2 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
AWDefault
As-welded deposit
Default: properties of the undiluted deposit as laid down by MIG/TIG, no post-weld heat treatment.1953503885 HB7 % IACS
SPOOLThis page
Spooled solid MIG wire, hard-drawn
Product-form condition of the wire itself on a spool — cold-drawn, stiff enough for good feedability.38052014150 HB6.5 % IACS

What is ERCuSi-A SPOOL?

ERCuSi-A SPOOL is ERCuSi-A supplied in the SPOOL condition — product-form condition of the wire itself on a spool — cold-drawn, stiff enough for good feedability. ERCuSi-A SPOOL has a yield strength of 380 MPa (55.1 ksi) and a tensile strength of 520 MPa (75.4 ksi) — stronger than 77% of copper alloy grades. Elongation at break is 14% and the elastic modulus is 103 GPa (14.9 Msi). ERCuSi-A SPOOL has a density of 8.53 g/cm³ (0.308 lb/in³), lighter than 62% of copper alloy grades. It melts at 970°C (1,778 °F). AW is the default condition FabDigit quotes; SPOOL is available on request or by drawing note.

Advantages

  • Readily welded — 90/100, better than 98% of copper alloy grades
  • Good corrosion resistance — 72/100, better than 84% of copper alloy grades
  • High strength — 380 MPa (55.1 ksi), better than 77% of copper alloy grades

Limitations

  • Limited service temperature — 150°C (302 °F), worse than 96% of copper alloy grades
  • Low electrical conductivity — 6.5 % IACS, worse than 91% of copper alloy grades
  • Poor heat conductor — 36 W/m·K (20.8 BTU/hr·ft·°F), worse than 86% of copper alloy grades

ERCuSi-A SPOOL properties

Typical room-temperature values for ERCuSi-A SPOOL; 20 are specific to this condition. Other listed values are ERCuSi-A reference data and may not represent this condition. Bars are the position among copper alloy grades.

Physical3

ERCuSi-A SPOOL has a density of 8.53 g/cm³ (0.308 lb/in³), lighter than 62% of copper alloy grades. It melts at 970°C (1,778 °F).

Density8.53 g/cm³0.31 lb/in³
Melting Point (Solidus)970°C1,778 °F
Liquidus Temperature1,025°C1,877 °F

Mechanical14

ERCuSi-A SPOOL has a yield strength of 380 MPa (55.1 ksi) and a tensile strength of 520 MPa (75.4 ksi) — stronger than 77% of copper alloy grades. Elongation at break is 14% and the elastic modulus is 103 GPa (14.9 Msi).

Elastic (Young's) Modulus103 GPa14.9 Msi
Shear Modulus38.5 GPa5.6 Msi
Bulk Modulus115 GPa16.7 Msi
Poisson's Ratio0.35
Tensile Strength (Ultimate)520 MPa75.4 ksi
Yield Strength (0.2% offset)380 MPa55.1 ksi
Elongation at Break14%
Reduction in Area30%
Shear Strength310 MPa45 ksi
Fatigue Strength (Endurance Limit)175 MPa25.4 ksi
Charpy V-Notch Impact (RT)30 J22.1 ft·lbf
Hardness, Brinell150 HB
Hardness, Rockwell B80 HRB
Hardness, Vickers158 HV

Thermal6

ERCuSi-A SPOOL is rated for continuous service to 150°C (302 °F). It conducts heat at 36 W/m·K (20.8 BTU/hr·ft·°F), worse than 86% of copper alloy grades. Thermal expansion is 18 µm/m·K (10 µin/in·°F).

Thermal Conductivity36 W/m·K20.8 BTU/hr·ft·°F
Specific Heat Capacity380 J/kg·K0.09 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)18 µm/m·K10 µin/in·°F
Latent Heat of Fusion205 J/g88.1 BTU/lb
Max Service Temperature (continuous)150°C302 °F
Min Service Temperature-196°C-321 °F

Electrical3

ERCuSi-A SPOOL conducts electricity at 6.5 % IACS, worse than 91% of copper alloy grades.

Electrical Conductivity6.5 % IACS
Electrical Resistivity2.65×10⁻⁷ Ω·m10.4 µΩ·in
Magnetic Responsenon-magnetic

Chemical & Environmental3

Corrosion resistance is very good (72/100), better than 84% of copper alloy grades.

Galvanic Potential (seawater, vs SCE)-0.26 V
Corrosion ResistanceVery good72/100
Chemical Resistance SummaryGood in seawater, fresh water, rural/marine atmospheres and most non-oxidizing acids; attacked by ammonia (SCC risk), nitric acid, sulphides, ferric/chromic salts and strong oxidizers.

Sustainability4

Producing a kilogram of ERCuSi-A SPOOL takes about 57 MJ of energy and emits 3.8 kg of CO₂ — less than 52% of copper alloy grades. Typical recycled content is 40%.

Embodied Energy (primary production)57 MJ/kg24,506 BTU/lb
Embodied Carbon (primary production)3.8 kg CO₂/kg
Embodied Water320 L/kg38.3 gal/lb
Typical Recycled Content40%

Manufacturability8

ERCuSi-A SPOOL's machinability is fair (35/100, better than 51% of copper alloy grades); weldability excellent (90/100); formability fair (45/100).

MachinabilityFair35/100
Machinability Rating (AISI 1212 = 100 %)32%
WeldabilityExcellent90/100
Formability (cold)Fair45/100
CastabilityGood60/100
Brazeability / SolderabilityExcellent92/100
PolishabilityVery good75/100
Anodizing Responsen/a — copper alloy; use chemical patina, clear lacquer or plating instead

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with ERCuSi-A SPOOL

Is ERCuSi-A easy to machine?

Deposits machine gummy like silicon bronze (~30 % of free-cutting brass) — sharp positive-rake tools, high speed, low feed, flood coolant.

Can ERCuSi-A be welded?

Excellent for short-arc/pulsed GMAW brazing of galvanized sheet with Ar or Ar+1–3 % O₂/CO₂; keep heat input and interpass temperature low (<150 °C) to avoid hot cracking and zinc burn-off.

Can ERCuSi-A be formed, bent or molded?

Wire is cold-drawn; deposits are ductile (30–50 % elongation) and tolerate joint flexing and light peening.

What surface finishes work on ERCuSi-A?

Cannot be anodized; take a bronze polish, chemical patina, or clear lacquer — colour-matches bronze/brass parts better than steel fillers.

ERCuSi-A chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
Siprincipal alloying element, gives fluidity and strength2.8 – 43.1
Mndeoxidizer / arc stabilizer≤ 1.51
Sn≤ 10.2
Fe≤ 0.50.1
Zn≤ 10.2
Alkept low to avoid oxide films in the weld pool≤ 0.010.01
Pb≤ 0.020.01
Other (total)AWS A5.7 total of other elements≤ 0.5—
Curemainder, ≈94–96 %balance—

ERCuSi-A SPOOL — frequently asked

What is ERCuSi-A SPOOL used for?

ERCuSi-A SPOOL is typically used for MIG brazing of galvanized sheet, silicon bronze pipe welding, dissimilar metal joining (steel-to-copper) and sculpture/art fabrication. In short: standard MIG-braze filler; low-heat joining of coated steel; bronze colour match.

What is the yield strength of ERCuSi-A SPOOL?

ERCuSi-A SPOOL has a typical yield strength of 380 MPa (55.1 ksi) and a tensile strength of 520 MPa (75.4 ksi) — stronger than 77% of copper alloy grades. Strength varies by condition: see the 2 listed tempers.

Is ERCuSi-A SPOOL easy to machine?

Not especially — machinability is rated fair (35/100, better than 51% of copper alloy grades). Deposits machine gummy like silicon bronze (~30 % of free-cutting brass) — sharp positive-rake tools, high speed, low feed, flood coolant.

Can ERCuSi-A SPOOL be welded?

Yes — weldability is rated excellent (90/100). Excellent for short-arc/pulsed GMAW brazing of galvanized sheet with Ar or Ar+1–3 % O₂/CO₂; keep heat input and interpass temperature low (<150 °C) to avoid hot cracking and zinc burn-off.

What surface finishes work on ERCuSi-A SPOOL?

Cannot be anodized; take a bronze polish, chemical patina, or clear lacquer — colour-matches bronze/brass parts better than steel fillers.

Can ERCuSi-A SPOOL be formed, bent or molded?

Wire is cold-drawn; deposits are ductile (30–50 % elongation) and tolerate joint flexing and light peening.

What is the maximum service temperature of ERCuSi-A SPOOL?

ERCuSi-A SPOOL is rated for continuous use to about 150°C (302 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between ERCuSi-A-AW and ERCuSi-A SPOOL?

AW is the default condition — default: properties of the undiluted deposit as laid down by MIG/TIG, no post-weld heat treatment. SPOOL: product-form condition of the wire itself on a spool — cold-drawn, stiff enough for good feedability. Yield strength is 195 MPa in AW versus 380 MPa in SPOOL.

Sources

  1. AWS A5.7/A5.7M — Specification for Copper and Copper-Alloy Bare Welding Rods and Electrodes — American Welding Society (2021)
  2. C65600 / silicon bronze alloy data — Copper Development Association (copper.org) (2023)
  3. ASM Handbook Vol.2 — Properties of Copper and Copper Alloys — ASM International (1990)
  4. Silicon bronze MIG/TIG filler wire datasheets — ESAB / Lincoln Electric / Böhler Welding (2023)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.