FabDigitFabDigit

PMMA-UV FR

Flame-retardant grade

GB GB/T 7134-2008 Type 3

FR = flame-retardant UV-stabilized acrylic sheet

Use where transparent weather-exposed panels must meet building fire ratings or vehicle interior/exterior burn classes; tensile falls to 60 MPa and elongation to 3.5 %.

Standard cost $$

Values for the FR condition

Other PMMA-UV grades and fills

PMMA-UV is listed in 6 conditions; see the grade overview at PMMA-UV.

Compare all 6 grades and fillsHide
Grade · open for datasheetBest forYield MPaTensile MPaElong. %Hardness
Impact-modified UV-stabilized acrylic
Pick the acrylate core-shell impact-modified version for outdoor signs, machine covers and guard panels exposed to knocks; elongation reaches 40 % but tensile drops to 50 MPa.—504060 HRM
FRThis page
Flame-retardant UV-stabilized acrylic sheet
Use where transparent weather-exposed panels must meet building fire ratings or vehicle interior/exterior burn classes; tensile falls to 60 MPa and elongation to 3.5 %.58603.587 Shore D
Extruded sheet, UV-stabilized
Choose the extruded sheet for high-volume light boxes and thermoformed parts: tighter thickness tolerance, lower cost and lower forming temperature, at 68 MPa tensile and 70 °C service.—684.590 HRM
UV-filtering / museum glazing grade
Choose the museum glazing grade with high UV-absorber loading to block more than 98 % of UV and stop artwork, exhibits and interiors fading, while the sheet itself stays weather-resistant.7174489 Shore D
UV-stabilized injection-molding pellet grade
Choose the UV-stabilized pellet grade when the weather-resistant part is injection moulded, such as headlamp covers, solar accessories and outdoor lenses at 72 MPa tensile.—724—
CastDefault
As cast
Default choice: use cell-cast sheet (GS) for outdoor signage and glazing needing the highest molecular weight, best weathering and solvent resistance, and flame-polishable edges.—754.595 HRM

What is PMMA-UV FR?

PMMA-UV FR is PMMA-UV in the FR grade — use where transparent weather-exposed panels must meet building fire ratings or vehicle interior/exterior burn classes; tensile falls to 60 MPa and elongation to 3.5 %. PMMA-UV FR has a yield strength of 58 MPa (8.41 ksi) and a tensile strength of 60 MPa (8.7 ksi) — stronger than 66% of polymer grades. Elongation at break is 3.5% and the elastic modulus is 3.1 GPa (0.45 Msi). PMMA-UV FR has a density of 1.23 g/cm³ (0.0444 lb/in³), heavier than 62% of polymer grades. Its glass-transition temperature is 110°C (230 °F). Cast is the default condition FabDigit quotes; FR is available on request or by drawing note.

Advantages

  • Polishes to a fine finish — 96/100, better than 99% of polymer grades
  • Good UV / weathering resistance — 96/100, better than 98% of polymer grades
  • Easy to machine — 76/100, better than 80% of polymer grades

Limitations

  • Low fracture toughness — 1.1 MPa·√m (1 ksi·√in), worse than 82% of polymer grades
  • Limited ductility — 3.5%, worse than 79% of polymer grades
  • Limited service temperature — 70°C (158 °F), worse than 77% of polymer grades

PMMA-UV FR properties

Typical room-temperature values for PMMA-UV FR; 29 are specific to this condition. Other listed values are PMMA-UV reference data and may not represent this condition. Bars are the position among polymer grades.

Physical6

PMMA-UV FR has a density of 1.23 g/cm³ (0.0444 lb/in³), heavier than 62% of polymer grades. Its glass-transition temperature is 110°C (230 °F).

Density1.23 g/cm³0.04 lb/in³
Glass Transition (Tg)110°C230 °F
Water Absorption (24 h)0.25%
Water Absorption (Saturation)2%
Refractive Index1.491
Light Transmission88%

Mechanical16

PMMA-UV FR has a yield strength of 58 MPa (8.41 ksi) and a tensile strength of 60 MPa (8.7 ksi) — stronger than 66% of polymer grades. Elongation at break is 3.5% and the elastic modulus is 3.1 GPa (0.45 Msi).

Elastic (Young's) Modulus3.1 GPa0.45 Msi
Shear Modulus1.2 GPa0.17 Msi
Bulk Modulus5 GPa0.73 Msi
Poisson's Ratio0.38
Tensile Strength (Ultimate)60 MPa8.7 ksi
Yield Strength (0.2% offset)58 MPa8.4 ksi
Elongation at Break3.5%
Compressive Strength100 MPa14.5 ksi
Compressive Modulus3 GPa0.44 Msi
Flexural Strength92 MPa13.3 ksi
Flexural Modulus3 GPa0.44 Msi
Shear Strength50 MPa7.3 ksi
Fracture Toughness (K_IC)1.1 MPa·√m1 ksi·√in
Izod Impact, Notched15 J/m0.28 ft·lbf/in
Hardness, Shore D87 Shore D
Hardness, Rockwell M91 HRM

Thermal11

PMMA-UV FR is rated for continuous service to 70°C (158 °F). It conducts heat at 0.2 W/m·K (0.116 BTU/hr·ft·°F), worse than 56% of polymer grades. Thermal expansion is 70 µm/m·K (38.9 µin/in·°F).

Thermal Conductivity0.2 W/m·K0.12 BTU/hr·ft·°F
Specific Heat Capacity1,470 J/kg·K0.35 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)70 µm/m·K38.9 µin/in·°F
Max Service Temperature (continuous)70°C158 °F
Min Service Temperature-40°C-40 °F
Heat Deflection Temp. @ 0.45 MPa98°C208 °F
Heat Deflection Temp. @ 1.8 MPa88°C190 °F
Vicat Softening Point (B50)100°C212 °F
Flammability (UL 94)—
Limiting Oxygen Index28%
Max Service Temperature (short-term)95°C203 °F

Electrical7

PMMA-UV FR is an electrical insulator with a dielectric strength of 25 kV/mm (635 V/mil) and a resistivity of 1×10¹² Ω·m.

Electrical Resistivity1×10¹² Ω·m3.94×10¹⁹ µΩ·in
Dielectric Strength25 kV/mm635 V/mil
Dielectric Constant (1 MHz)2.75
Dissipation Factor (1 MHz)0.02
Volume Resistivity1×10¹⁵ Ω·cm
Surface Resistivity1×10¹⁶ Ω
Comparative Tracking Index (CTI)600 V

Chemical & Environmental3

Corrosion resistance is very good (74/100), worse than 68% of polymer grades. UV resistance is excellent.

Corrosion ResistanceVery good74/100
UV / Weathering ResistanceExcellent96/100
Chemical Resistance Summary—

Sustainability4

Producing a kilogram of PMMA-UV FR takes about 103 MJ of energy and emits 5.5 kg of CO₂ — less than 54% of polymer grades. Typical recycled content is 2%.

Embodied Energy (primary production)103 MJ/kg44,282 BTU/lb
Embodied Carbon (primary production)5.5 kg CO₂/kg
Embodied Water250 L/kg30 gal/lb
Typical Recycled Content2%

Manufacturability7

PMMA-UV FR's machinability is very good (76/100, better than 80% of polymer grades); weldability fair (35/100); formability good (58/100).

MachinabilityVery good76/100
WeldabilityFair35/100
Formability (cold)Good58/100
PolishabilityExcellent96/100
Mold Shrinkage0.5%
Processing Melt Temperature (typ.)240°C464 °F
Mold Temperature (typ.)70°C158 °F

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with PMMA-UV FR

Is PMMA-UV easy to machine?

Dry-cut with sharp single-flute or polished-flute cutters at high spindle speed and low feed; regrind drills to zero rake so they do not grab and break out the exit edge. Anneal at 80 °C for 1–2 h per mm after machining to remove the stress-cracking risk.

Can PMMA-UV be welded?

Structural parts cannot be fusion welded; bond with dichloromethane/MMA monomer cement or two-part acrylic adhesive. Hot-gas and ultrasonic welding are usable but give brittle joints.

Can PMMA-UV be formed, bent or molded?

Thermoform at 150–175 °C (lower end for extruded sheet, upper end for cast) after several hours of drying at 80 °C. Dry moulding pellets 3–4 h at 80–100 °C and avoid overheating, which degrades the melt and produces gas streaks.

What surface finishes work on PMMA-UV?

Edges can be flame-polished or diamond fly-cut to an optical surface. The sheet accepts screen printing, UV spray coating and vacuum aluminising; coatings and cleaners must be free of alcohol and ammonia to prevent stress cracking.

PMMA-UV chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
methyl acrylate / ethyl acrylate comonomimproves thermal stability during extrusion0 – 41
UV absorber (benzotriazole / benzophenoncore component of the weathering package0.1 – 10.4
HALS light stabilizer0.05 – 0.50.15
processing lubricant / release agentstearyl alcohol type, injection molding grades0 – 0.50.2
methyl methacrylate (MMA) unitscast sheet near-homopolymer; extruded sheet has some comonomer≥ 95 (balance)—

PMMA-UV FR — frequently asked

What is PMMA-UV FR used for?

PMMA-UV FR is typically used for outdoor signage, solar collector glazing, greenhouse panels and outdoor advertising displays. In short: weathering-grade acrylic sheet; 80 °C service limit; no outdoor yellowing.

What is the yield strength of PMMA-UV FR?

PMMA-UV FR has a typical yield strength of 58 MPa (8.41 ksi) and a tensile strength of 60 MPa (8.7 ksi) — stronger than 66% of polymer grades. Strength varies by condition: see the 6 listed tempers.

Is PMMA-UV FR easy to machine?

Yes — machinability is rated very good (76/100, better than 80% of polymer grades). Dry-cut with sharp single-flute or polished-flute cutters at high spindle speed and low feed; regrind drills to zero rake so they do not grab and break out the exit edge. Anneal at 80 °C for 1–2 h per mm after machining to remove the stress-cracking risk.

Can PMMA-UV FR be welded?

With care — weldability is rated fair (35/100). Structural parts cannot be fusion welded; bond with dichloromethane/MMA monomer cement or two-part acrylic adhesive. Hot-gas and ultrasonic welding are usable but give brittle joints.

What surface finishes work on PMMA-UV FR?

Edges can be flame-polished or diamond fly-cut to an optical surface. The sheet accepts screen printing, UV spray coating and vacuum aluminising; coatings and cleaners must be free of alcohol and ammonia to prevent stress cracking.

Can PMMA-UV FR be formed, bent or molded?

Thermoform at 150–175 °C (lower end for extruded sheet, upper end for cast) after several hours of drying at 80 °C. Dry moulding pellets 3–4 h at 80–100 °C and avoid overheating, which degrades the melt and produces gas streaks.

What is the maximum service temperature of PMMA-UV FR?

PMMA-UV FR is rated for continuous use to about 70°C (158 °F), and briefly to 95°C. Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between PMMA-UV Cast and PMMA-UV UVA?

Cast is the default condition — default choice: use cell-cast sheet (GS) for outdoor signage and glazing needing the highest molecular weight, best weathering and solvent resistance, and flame-polishable edges. UVA: choose the museum glazing grade with high UV-absorber loading to block more than 98 % of UV and stop artwork, exhibits and interiors fading, while the sheet itself stays weather-resistant. Yield strength is 58 MPa in Cast versus 71 MPa in UVA.

Sources

  1. ISO 7823-1 Poly(methyl methacrylate) sheets — cast sheets — ISO (2003)
  2. ASTM D4802 Poly(methyl methacrylate) Acrylic Plastic Sheet — ASTM (2021)
  3. PLEXIGLAS GS / XT cast & extruded sheet data — Röhm GmbH (2023)
  4. ACRYLITE sheet and molding compound technical data — Mitsubishi Chemical (2023)
  5. CAMPUS plastics — PMMA property tables — CWFG (2024)
  6. Engineered Materials Handbook Vol.2: Engineering Plastics — ASM International (1988)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.