FabDigitFabDigit

Steel VDC OT-D6.0-10.0

Other

GB VDC

OT-D6.0-10.0 = oT, diameter > 6.00–10.00 mm

Largest VDC sizes; choose an alloyed grade (VDCrV/VDSiCr) if full through-hardening or higher stress is required.

Standard cost $$

Values for the OT-D6.0-10.0 condition

Other VDC tempers and conditions

VDC is listed in 7 conditions; see the grade overview at VDC.

Compare all 7 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
OT-D6.0-10.0This page
OT, diameter > 6.00–10.00 mm
Largest VDC sizes; choose an alloyed grade (VDCrV/VDSiCr) if full through-hardening or higher stress is required.1,4101,600846 HRC8.6 % IACS
OT, diameter > 4.00–6.00 mm
Medium-heavy wire; strength drops with section due to reduced hardenability of the plain-carbon grade.1,4801,680748 HRC8.6 % IACS
OTDefault
Oil hardened and tempered, as supplied
Standard stocked condition: quenched-and-tempered wire ready for cold coiling of medium-size valve/clutch springs.1,5601,770650 HRC8.6 % IACS
Stress relieved
Condition of the finished spring after coiling and low-temperature stress relief — raises elastic limit and sets free length.1,6201,750549 HRC8.6 % IACS
Shot peened (+ stress relieved) spring
Pick for high-cycle valve springs: compressive surface stress lifts fatigue limit 20–35 % over unpeened wire.1,6301,750650 HRC8.6 % IACS
OT, diameter > 1.00–2.00 mm
Common size band for small engine valve springs and control springs.1,6401,8605.552 HRC8.6 % IACS
OT, diameter 0.50–1.00 mm
Fine wire for small precision valve springs; highest strength band of the VDC table.1,7001,930553 HRC8.6 % IACS

What is VDC OT-D6.0-10.0?

VDC OT-D6.0-10.0 is VDC in the OT-D6.0-10.0 condition — largest VDC sizes; choose an alloyed grade (VDCrV/VDSiCr) if full through-hardening or higher stress is required. VDC OT-D6.0-10.0 has a yield strength of 1,410 MPa (205 ksi) and a tensile strength of 1,600 MPa (232 ksi) — stronger than 96% of steel grades. Elongation at break is 8% and the elastic modulus is 206 GPa (29.9 Msi). VDC OT-D6.0-10.0 has a density of 7.85 g/cm³ (0.284 lb/in³), heavier than 56% of steel grades. It melts at 1,420°C (2,588 °F). OT is the default condition FabDigit quotes; OT-D6.0-10.0 is available on request or by drawing note.

Advantages

  • High strength — 1,410 MPa (205 ksi), better than 96% of steel grades

Limitations

  • Limited service temperature — 150°C (302 °F), worse than 99% of steel grades
  • Difficult to weld — 10/100, worse than 99% of steel grades
  • Difficult to machine — 15/100, worse than 98% of steel grades
  • Low fracture toughness — 28 MPa·√m (25.5 ksi·√in), worse than 97% of steel grades
  • Limited ductility — 8%, worse than 95% of steel grades

VDC OT-D6.0-10.0 properties

Typical room-temperature values for VDC OT-D6.0-10.0; 21 are specific to this condition. Other listed values are VDC reference data and may not represent this condition. Bars are the position among steel grades.

Physical3

VDC OT-D6.0-10.0 has a density of 7.85 g/cm³ (0.284 lb/in³), heavier than 56% of steel grades. It melts at 1,420°C (2,588 °F).

Density7.85 g/cm³0.28 lb/in³
Melting Point (Solidus)1,420°C2,588 °F
Liquidus Temperature1,490°C2,714 °F

Mechanical15

VDC OT-D6.0-10.0 has a yield strength of 1,410 MPa (205 ksi) and a tensile strength of 1,600 MPa (232 ksi) — stronger than 96% of steel grades. Elongation at break is 8% and the elastic modulus is 206 GPa (29.9 Msi).

Elastic (Young's) Modulus206 GPa29.9 Msi
Shear Modulus79.5 GPa11.5 Msi
Bulk Modulus165 GPa23.9 Msi
Poisson's Ratio0.29
Tensile Strength (Ultimate)1,600 MPa232 ksi
Yield Strength (0.2% offset)1,410 MPa205 ksi
Elongation at Break8%
Reduction in Area48%
Compressive Strength1,480 MPa215 ksi
Shear Strength960 MPa139 ksi
Fatigue Strength (Endurance Limit)660 MPa95.7 ksi
Fracture Toughness (K_IC)28 MPa·√m25.5 ksi·√in
Hardness, Brinell432 HB
Hardness, Rockwell C46 HRC
Hardness, Vickers470 HV

Thermal6

VDC OT-D6.0-10.0 is rated for continuous service to 150°C (302 °F). It conducts heat at 46 W/m·K (26.6 BTU/hr·ft·°F), better than 71% of steel grades. Thermal expansion is 12 µm/m·K (6.67 µin/in·°F).

Thermal Conductivity46 W/m·K26.6 BTU/hr·ft·°F
Specific Heat Capacity470 J/kg·K0.11 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)12 µm/m·K6.7 µin/in·°F
Latent Heat of Fusion250 J/g107 BTU/lb
Max Service Temperature (continuous)150°C302 °F
Min Service Temperature-50°C-58 °F

Electrical3

VDC OT-D6.0-10.0 conducts electricity at 8.6 % IACS, better than 66% of steel grades.

Electrical Conductivity8.6 % IACS
Electrical Resistivity2×10⁻⁷ Ω·m7.87 µΩ·in
Magnetic Responseferromagnetic

Chemical & Environmental3

Corrosion resistance is not recommended (12/100), worse than 53% of steel grades.

Galvanic Potential (seawater, vs SCE)-0.6 V
Corrosion ResistanceNot recommended12/100
Chemical Resistance SummaryNo inherent corrosion resistance: rusts in humid air, attacked by acids and chlorides; hardened high-carbon martensite is sensitive to hydrogen embrittlement, so acid pickling and electroplating must be followed by a bake-out. Normally supplied phosphated/oiled or zinc-coated.

Sustainability4

Producing a kilogram of VDC OT-D6.0-10.0 takes about 30 MJ of energy and emits 2.2 kg of CO₂ — more than 56% of steel grades. Typical recycled content is 20%.

Embodied Energy (primary production)30 MJ/kg12,898 BTU/lb
Embodied Carbon (primary production)2.2 kg CO₂/kg
Embodied Water60 L/kg7.2 gal/lb
Typical Recycled Content20%

Manufacturability7

VDC OT-D6.0-10.0's machinability is poor (15/100, worse than 98% of steel grades); weldability not recommended (10/100); formability fair (50/100).

MachinabilityPoor15/100
Machinability Rating (AISI 1212 = 100 %)15%
WeldabilityNot recommended10/100
Formability (cold)Fair50/100
Brazeability / SolderabilityPoor30/100
PolishabilityGood55/100
Anodizing Responsen/a — ferrous alloy; use zinc/zinc-nickel plating (with hydrogen bake-out), phosphating, or epoxy coating

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with VDC OT-D6.0-10.0

Is VDC easy to machine?

Supplied at ~50 HRC — not machined; ends are ground with CBN/alumina wheels and coolant to avoid grinding burns and re-hardened white layers.

Can VDC be welded?

Effectively unweldable: high carbon plus quenched martensite gives cracking and destroys the temper; use mechanical hooks or ground/closed ends instead.

Can VDC be formed, bent or molded?

Cold coiled directly from the OT coil on CNC coilers, then stress relieved at 250–400 °C; keep index above ~4 and avoid nicks, as surface defects control spring life.

What surface finishes work on VDC?

Shot peen and preset for fatigue, then phosphate + oil, zinc or zinc-nickel plating or epoxy paint; always bake at ~200 °C after acid pickling/plating to relieve hydrogen.

VDC chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
Cunalloyed valve-spring quality0.6 – 0.750.68
Si0.15 – 0.350.25
Mn0.6 – 0.90.75
Ptighter than FDC/TDC≤ 0.02—
Stighter than FDC/TDC≤ 0.02—
Crresidual≤ 0.1—
Curesidual≤ 0.12—
Niresidual≤ 0.12—
Febalance—

VDC OT-D6.0-10.0 — frequently asked

What is VDC OT-D6.0-10.0 used for?

VDC OT-D6.0-10.0 is typically used for engine valve springs, precision compression springs and small mechanical springs. In short: entry-level valve-spring wire; unalloyed carbon OT grade; lowest-cost VD quality.

What is the yield strength of VDC OT-D6.0-10.0?

VDC OT-D6.0-10.0 has a typical yield strength of 1,410 MPa (205 ksi) and a tensile strength of 1,600 MPa (232 ksi) — stronger than 96% of steel grades. Strength varies by condition: see the 7 listed tempers.

Is VDC OT-D6.0-10.0 easy to machine?

Not especially — machinability is rated poor (15/100, worse than 98% of steel grades). Supplied at ~50 HRC — not machined; ends are ground with CBN/alumina wheels and coolant to avoid grinding burns and re-hardened white layers.

Can VDC OT-D6.0-10.0 be welded?

Not readily — weldability is rated not recommended (10/100). Effectively unweldable: high carbon plus quenched martensite gives cracking and destroys the temper; use mechanical hooks or ground/closed ends instead.

What surface finishes work on VDC OT-D6.0-10.0?

Shot peen and preset for fatigue, then phosphate + oil, zinc or zinc-nickel plating or epoxy paint; always bake at ~200 °C after acid pickling/plating to relieve hydrogen.

Can VDC OT-D6.0-10.0 be formed, bent or molded?

Cold coiled directly from the OT coil on CNC coilers, then stress relieved at 250–400 °C; keep index above ~4 and avoid nicks, as surface defects control spring life.

What is the maximum service temperature of VDC OT-D6.0-10.0?

VDC OT-D6.0-10.0 is rated for continuous use to about 150°C (302 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between VDC-OT and VDC-SP?

OT is the default condition — standard stocked condition: quenched-and-tempered wire ready for cold coiling of medium-size valve/clutch springs. SP: pick for high-cycle valve springs: compressive surface stress lifts fatigue limit 20–35 % over unpeened wire. Yield strength is 1,560 MPa in OT versus 1,630 MPa in SP.

Sources

  1. EN 10270-2 — Steel wire for mechanical springs, Part 2: Oil hardened and tempered spring steel wire — CEN (2011)
  2. ASM Handbook Vol.1 — Properties and Selection: Irons, Steels and High-Performance Alloys (spring steels) — ASM International (1990)
  3. Oil tempered valve spring wire datasheets (Suzuki Garphyttan / Bekaert / Kiswire) — various producers (2023)
  4. SMI Handbook of Spring Design — Spring Manufacturers Institute (2013)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.