FabDigitFabDigit

PVC-P SHA60

Hardness band

ISO 1043 PVC-P

SHA60 = shore A 60

Pick for very flexible tubing, soft hose and lay-flat film where drape matters more than strength.

Budget cost $

Values for the SHA60 condition

Other PVC-P grades and fills

PVC-P is listed in 10 conditions; see the grade overview at PVC-P.

Compare all 10 grades and fillsHide
Grade · open for datasheetBest forYield MPaTensile MPaElong. %Hardness
Cellular / foamed flexible PVC
Pick for weather-strip, sponge gaskets and cushioned profiles where compressibility and low weight matter.—418010 Shore D
Clear / transparent unfilled compound
Pick for sight-glass tubing, transparent hose and flexible windows where flow visibility is required.81632028 Shore D
SHA60This page
Shore A 60
Pick for very flexible tubing, soft hose and lay-flat film where drape matters more than strength.—1140015 Shore D
Shore A 70
Pick for flexible cable jackets, gaskets and clear tubing needing a balance of softness and tear strength.—1335022 Shore D
Low-temperature grade
Pick for outdoor cords, refrigeration hose and cold-climate seals needing flexibility below −30 °C.—1335023 Shore D
flame-retardant / low-smoke compound
Pick for building wire, appliance cords and rail/transport parts needing UL 94 V-0 and reduced smoke.—1423034 Shore D
SHA80Default
Shore A 80
Default flexible PVC: wire insulation, hose, profiles and moulded plugs; best all-round property/price balance.—1630030 Shore D
Non-phthalate (DOTP/DINCH) plasticized
Pick where REACH/RoHS phthalate restrictions apply — toys, consumer cords, food-contact and EU market goods.—1630030 Shore D
105 °C heat-stabilized cable grade
Pick for automotive and appliance wiring rated 105 °C; uses trimellitate/polymeric plasticizer and boosted stabilizer.—1825038 Shore D
Shore A 90
Pick for semi-rigid profiles, edge banding, shoe soles and stiff hose where shape retention is needed.—2224040 Shore D

What is PVC-P SHA60?

PVC-P SHA60 is PVC-P heat treated to SHA60 — pick for very flexible tubing, soft hose and lay-flat film where drape matters more than strength. PVC-P SHA60 has a tensile strength of 11 MPa (1.6 ksi), weaker than 78% of polymer grades. Elongation at break is 400% and the elastic modulus is 0.01 GPa (0.001 Msi). PVC-P SHA60 has a density of 1.2 g/cm³ (0.0434 lb/in³), heavier than 57% of polymer grades. Its glass-transition temperature is -10°C (14 °F). SHA80 is the default condition FabDigit quotes; SHA60 is available on request or by drawing note.

Advantages

  • Forms and bends easily — 96/100, better than 100% of polymer grades
  • Readily welded — 94/100, better than 98% of polymer grades
  • Low embodied carbon — 2.7 kg CO₂/kg, better than 87% of polymer grades
  • Ductile — tolerates forming and impact — 400%, better than 86% of polymer grades

Limitations

  • Difficult to machine — 25/100, worse than 93% of polymer grades
  • High mold shrinkage — 2.5%, worse than 93% of polymer grades
  • Limited service temperature — 60°C (140 °F), worse than 87% of polymer grades
  • Low stiffness — 0.01 GPa (0.001 Msi), worse than 84% of polymer grades
  • Hard to polish — 30/100, worse than 82% of polymer grades

PVC-P SHA60 properties

Typical room-temperature values for PVC-P SHA60; 21 are specific to this condition. Other listed values are PVC-P reference data and may not represent this condition. Bars are the position among polymer grades.

Physical6

PVC-P SHA60 has a density of 1.2 g/cm³ (0.0434 lb/in³), heavier than 57% of polymer grades. Its glass-transition temperature is -10°C (14 °F).

Density1.2 g/cm³0.04 lb/in³
Glass Transition (Tg)-10°C14 °F
Water Absorption (24 h)0.35%
Water Absorption (Saturation)1%
Refractive Index1.54
Light Transmission82%

Mechanical10

PVC-P SHA60 has a tensile strength of 11 MPa (1.6 ksi), weaker than 78% of polymer grades. Elongation at break is 400% and the elastic modulus is 0.01 GPa (0.001 Msi).

Elastic (Young's) Modulus0.01 GPa0 Msi
Poisson's Ratio0.45
Tensile Strength (Ultimate)11 MPa1.6 ksi
Elongation at Break400%
Flexural Modulus0.01 GPa8.7×10⁻⁴ Msi
Shear Strength6 MPa0.87 ksi
Hardness, Shore A60 Shore A
Hardness, Shore D15 Shore D
Tear Strength28 kN/m160 lbf/in
Compression Set (22 h, 70 °C)40%

Thermal9

PVC-P SHA60 is rated for continuous service to 60°C (140 °F). It conducts heat at 0.15 W/m·K (0.0867 BTU/hr·ft·°F), worse than 80% of polymer grades. Thermal expansion is 150 µm/m·K (83.3 µin/in·°F).

Thermal Conductivity0.15 W/m·K0.09 BTU/hr·ft·°F
Specific Heat Capacity1,200 J/kg·K0.29 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)150 µm/m·K83.3 µin/in·°F
Max Service Temperature (continuous)60°C140 °F
Min Service Temperature-35°C-31 °F
Vicat Softening Point (B50)48°C118 °F
Flammability (UL 94)Typically V-0 to V-2 depending on plasticizer loading and FR package; self-extinguishing due to chlorine but produces dense smoke and HCl
Limiting Oxygen Index23%
Max Service Temperature (short-term)100°C212 °F

Electrical7

PVC-P SHA60 is an electrical insulator with a dielectric strength of 20 kV/mm (508 V/mil) and a resistivity of 1×10¹⁰ Ω·m.

Electrical Resistivity1×10¹⁰ Ω·m3.94×10¹⁷ µΩ·in
Dielectric Strength20 kV/mm508 V/mil
Dielectric Constant (1 MHz)4.5
Dissipation Factor (1 MHz)0.09
Volume Resistivity1×10¹³ Ω·cm
Surface Resistivity1×10¹³ Ω
Comparative Tracking Index (CTI)600 V

Chemical & Environmental3

Corrosion resistance is very good (78/100), worse than 61% of polymer grades. UV resistance is fair.

Corrosion ResistanceVery good78/100
UV / Weathering ResistanceFair50/100
Chemical Resistance SummaryGood against dilute acids, alkalis, salts, alcohols, oils and water; attacked or swollen by ketones, esters, chlorinated solvents, aromatic hydrocarbons and THF; plasticizer can be extracted by hot oils, fats and some solvents causing embrittlement

Sustainability4

Producing a kilogram of PVC-P SHA60 takes about 68 MJ of energy and emits 2.7 kg of CO₂ — less than 94% of polymer grades. Typical recycled content is 10%.

Embodied Energy (primary production)68 MJ/kg29,235 BTU/lb
Embodied Carbon (primary production)2.7 kg CO₂/kg
Embodied Water200 L/kg24 gal/lb
Typical Recycled Content10%

Manufacturability7

PVC-P SHA60's machinability is poor (25/100, worse than 93% of polymer grades); weldability excellent (94/100); formability excellent (96/100).

MachinabilityPoor25/100
WeldabilityExcellent94/100
Formability (cold)Excellent96/100
PolishabilityPoor30/100
Mold Shrinkage2.5%
Processing Melt Temperature (typ.)175°C347 °F
Mold Temperature (typ.)35°C95 °F

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with PVC-P SHA60

Is PVC-P easy to machine?

Machinable but gummy — use sharp positive-rake tools, high rake angles, generous chip clearance and low cutting speed with air cooling; die-cutting, slitting and waterjet are usually preferred over milling.

Can PVC-P be welded?

Excellent high-frequency (dielectric) and hot-air/hot-wedge weldability due to the polar C–Cl bond; solvent bonding with THF/MEK cements and hot-plate welding also work; avoid overheating, which liberates HCl.

Can PVC-P be formed, bent or molded?

Extruded, calendered, injection or dip-molded at 155–195 °C melt with mold 20–55 °C; keep residence time short and use stainless or hard-chromed, well-vented tooling since degradation releases corrosive HCl.

What surface finishes work on PVC-P?

Accepts embossing, printing with PVC-compatible inks and lacquer topcoats; surfaces should be cleaned of plasticizer bloom before bonding, and plasticizer migration must be checked against adjacent paints, PC/ABS parts and elastomers.

PVC-P chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
plasticizer (DINP/DOP/DOTP/DINCH/trimelltypically 30–60 phr; sets hardness and Tg20 – 4530
filler (CaCO3)cost/stiffness modifier0 – 255
heat stabilizer (Ca-Zn, Ba-Zn or organot1 – 52.5
lubricant / processing aid0.2 – 1.50.6
flame retardant / smoke suppressant (Sb2only in FR grades0 – 100
pigment / UV stabilizer0 – 31
PVC resin (polyvinyl chloride, K65–K70)suspension resin, K-value chosen by process≥ 50 (balance)—

PVC-P SHA60 — frequently asked

What is PVC-P SHA60 used for?

PVC-P SHA60 is typically used for electrical wire & cable insulation/jacketing, flexible tubing and hose, vinyl flooring and film/sheet and inflatable products and gaskets. In short: flexible, RF-weldable PVC; low-cost cable insulation; 300 % elongation.

What is the tensile strength of PVC-P SHA60?

PVC-P SHA60 has a typical tensile strength of 11 MPa (1.6 ksi) — weaker than 78% of polymer grades. Strength varies by condition: see the 10 listed tempers.

Is PVC-P SHA60 easy to machine?

Not especially — machinability is rated poor (25/100, worse than 93% of polymer grades). Machinable but gummy — use sharp positive-rake tools, high rake angles, generous chip clearance and low cutting speed with air cooling; die-cutting, slitting and waterjet are usually preferred over milling.

Can PVC-P SHA60 be welded?

Yes — weldability is rated excellent (94/100). Excellent high-frequency (dielectric) and hot-air/hot-wedge weldability due to the polar C–Cl bond; solvent bonding with THF/MEK cements and hot-plate welding also work; avoid overheating, which liberates HCl.

What surface finishes work on PVC-P SHA60?

Accepts embossing, printing with PVC-compatible inks and lacquer topcoats; surfaces should be cleaned of plasticizer bloom before bonding, and plasticizer migration must be checked against adjacent paints, PC/ABS parts and elastomers.

Can PVC-P SHA60 be formed, bent or molded?

Extruded, calendered, injection or dip-molded at 155–195 °C melt with mold 20–55 °C; keep residence time short and use stainless or hard-chromed, well-vented tooling since degradation releases corrosive HCl.

What is the maximum service temperature of PVC-P SHA60?

PVC-P SHA60 is rated for continuous use to about 60°C (140 °F), and briefly to 100°C. Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between PVC-P SHA80 and PVC-P CLR?

SHA80 is the default condition — default flexible PVC: wire insulation, hose, profiles and moulded plugs; best all-round property/price balance. CLR: pick for sight-glass tubing, transparent hose and flexible windows where flow visibility is required.

Sources

  1. ASTM D2287 — Nonrigid Vinyl Chloride Polymer and Copolymer Molding and Extrusion Compounds — ASTM International (2019)
  2. ASTM D638 / D2240 / D624 test methods for tensile, durometer and tear — ASTM International (2022)
  3. Engineered Materials Handbook Vol. 2: Engineering Plastics — ASM International (1988)
  4. CAMPUS / UL Prospector plasticized PVC compound datasheets — CWFG / UL (2024)
  5. Flexible PVC cable and tubing compound datasheets (Teknor Apex, Benvic, Sylvin) — various compounders (2024)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.