FabDigitFabDigit

Copper Alloy C70620-HR50

Supply condition

UNS C70620

HR50 = cold worked and stress relieved

Cold-drawn tube given a low-temperature stress relief to cut residual stress before seawater or condensate service.

High cost $$$$

Values for the HR50 condition

Other C70620 tempers and conditions

C70620 is listed in 7 conditions; see the grade overview at C70620.

Compare all 7 conditionsHide
Condition · open for datasheetBest forYield MPaTensile MPaElong. %HardnessConductivity
O60Default
Soft annealed
Standard condition for condenser/heat-exchanger tube, U-bends and cold-formed parts; maximum ductility and best corrosion consistency.1203104065 HB9.5 % IACS
As hot rolled
Mill hot-worked plate, tube shell or extrusion, taken as-processed; used where subsequent forming, welding or machining will follow.1353203570 HB9.5 % IACS
Quarter hard
Light temper for tube and strip needing higher yield strength while retaining useful bendability.2553652095 HB9.5 % IACS
HR50This page
Cold worked and stress relieved
Cold-drawn tube given a low-temperature stress relief to cut residual stress before seawater or condensate service.33040015110 HB9 % IACS
Half hard
General structural temper for strip, sheet and drawn tube where strength matters more than deep forming.36041512120 HB9.5 % IACS
Extra hard
Heavily cold-worked strip/tube for high-strength, wear- and pressure-resisting parts with only slight forming.4504906150 HB9.5 % IACS
Spring hard
Maximum cold-worked strength for springy strip, clips and diaphragms in marine/condensate environments.4855254165 HB9.5 % IACS

What is C70620-HR50?

C70620-HR50 is C70620 supplied in the HR50 condition — cold-drawn tube given a low-temperature stress relief to cut residual stress before seawater or condensate service. C70620-HR50 has a yield strength of 330 MPa (47.9 ksi) and a tensile strength of 400 MPa (58 ksi) — stronger than 69% of copper alloy grades. Elongation at break is 15% and the elastic modulus is 124 GPa (18 Msi). C70620-HR50 has a density of 8.94 g/cm³ (0.323 lb/in³), heavier than 90% of copper alloy grades. It melts at 1,100°C (2,012 °F). O60 is the default condition FabDigit quotes; HR50 is available on request or by drawing note.

Advantages

  • Good corrosion resistance — 80/100, better than 96% of copper alloy grades
  • Readily welded — 85/100, better than 95% of copper alloy grades
  • High service temperature — 300°C (572 °F), better than 85% of copper alloy grades

Limitations

  • High embodied carbon — 5.2 kg CO₂/kg, worse than 88% of copper alloy grades
  • Poor heat conductor — 40 W/m·K (23.1 BTU/hr·ft·°F), worse than 82% of copper alloy grades
  • Low electrical conductivity — 9 % IACS, worse than 78% of copper alloy grades

C70620-HR50 properties

Typical room-temperature values for C70620-HR50; 20 are specific to this condition. Other listed values are C70620 reference data and may not represent this condition. Bars are the position among copper alloy grades.

Physical3

C70620-HR50 has a density of 8.94 g/cm³ (0.323 lb/in³), heavier than 90% of copper alloy grades. It melts at 1,100°C (2,012 °F).

Density8.94 g/cm³0.32 lb/in³
Melting Point (Solidus)1,100°C2,012 °F
Liquidus Temperature1,145°C2,093 °F

Mechanical14

C70620-HR50 has a yield strength of 330 MPa (47.9 ksi) and a tensile strength of 400 MPa (58 ksi) — stronger than 69% of copper alloy grades. Elongation at break is 15% and the elastic modulus is 124 GPa (18 Msi).

Elastic (Young's) Modulus124 GPa18 Msi
Shear Modulus47 GPa6.8 Msi
Bulk Modulus130 GPa18.9 Msi
Poisson's Ratio0.33
Tensile Strength (Ultimate)400 MPa58 ksi
Yield Strength (0.2% offset)330 MPa47.9 ksi
Elongation at Break15%
Reduction in Area45%
Shear Strength260 MPa37.7 ksi
Fatigue Strength (Endurance Limit)140 MPa20.3 ksi
Charpy V-Notch Impact (RT)70 J51.6 ft·lbf
Hardness, Brinell110 HB
Hardness, Rockwell B68 HRB
Hardness, Vickers118 HV

Thermal6

C70620-HR50 is rated for continuous service to 300°C (572 °F). It conducts heat at 40 W/m·K (23.1 BTU/hr·ft·°F), worse than 82% of copper alloy grades. Thermal expansion is 17.1 µm/m·K (9.5 µin/in·°F).

Thermal Conductivity40 W/m·K23.1 BTU/hr·ft·°F
Specific Heat Capacity377 J/kg·K0.09 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)17.1 µm/m·K9.5 µin/in·°F
Latent Heat of Fusion210 J/g90.3 BTU/lb
Max Service Temperature (continuous)300°C572 °F
Min Service Temperature-200°C-328 °F

Electrical3

C70620-HR50 conducts electricity at 9 % IACS, worse than 78% of copper alloy grades.

Electrical Conductivity9 % IACS
Electrical Resistivity1.92×10⁻⁷ Ω·m7.56 µΩ·in
Magnetic Responsenon-magnetic

Chemical & Environmental3

Corrosion resistance is very good (80/100), better than 96% of copper alloy grades.

Galvanic Potential (seawater, vs SCE)-0.28 V
Corrosion ResistanceVery good80/100
Chemical Resistance SummaryExcellent in flowing seawater, brackish and condensate water with inherent biofouling resistance; resists chloride SCC. Attacked by ammonia/amines, sulfide-polluted water, oxidising acids and mercury compounds; velocity limit roughly 3–3.5 m/s in tubes.

Sustainability4

Producing a kilogram of C70620-HR50 takes about 70 MJ of energy and emits 5.2 kg of CO₂ — more than 84% of copper alloy grades. Typical recycled content is 25%.

Embodied Energy (primary production)70 MJ/kg30,095 BTU/lb
Embodied Carbon (primary production)5.2 kg CO₂/kg
Embodied Water260 L/kg31.2 gal/lb
Typical Recycled Content25%

Manufacturability8

C70620-HR50's machinability is fair (35/100, better than 51% of copper alloy grades); weldability excellent (85/100); formability good (60/100).

MachinabilityFair35/100
Machinability Rating (AISI 1212 = 100 %)25%
WeldabilityExcellent85/100
Formability (cold)Good60/100
CastabilityFair45/100
Brazeability / SolderabilityExcellent88/100
PolishabilityVery good70/100
Anodizing Responsen/a — copper alloy; use pickling/passivation or protective ferrous-sulphate dosing instead

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with C70620-HR50

Is C70620 easy to machine?

Gummy and work-hardening — rate ≈20 % of free-cutting brass; use sharp positive-rake carbide, moderate speed, heavy feed and generous coolant to avoid built-up edge.

Can C70620 be welded?

Designed for welding: GTAW/GMAW with C7158 (65/35 Cu-Ni) filler, no preheat, low interpass temperature, argon back-purge; keep joints oil- and sulphur-free to avoid hot cracking.

Can C70620 be formed, bent or molded?

Excellent cold formability in O60 (deep drawing, U-bending, expansion); work-hardens fast, so interstage anneal at 700–850 °C with rapid cooling; hot work 850–950 °C.

What surface finishes work on C70620?

Not anodizable; pickle in sulphuric/hydrogen-peroxide or inhibited nitric to remove weld oxide, then form the protective film with clean-water commissioning (or FeSO₄ dosing); takes a good mechanical or electro-polish.

C70620 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
Niincludes Co9 – 1110
Feiron addition gives impingement resistance1 – 1.81.5
Mncontrolled range (deoxidation, weldability)0.5 – 10.7
Zn≤ 0.5—
Pbtightened vs C70600 for weldability≤ 0.02—
C≤ 0.05—
S≤ 0.02—
P≤ 0.02—
CuCu + Ag remainder, ≈86.5 % minbalance—

C70620-HR50 — frequently asked

What is C70620-HR50 used for?

C70620-HR50 is typically used for nuclear plant condenser tubes, power plant heat exchangers and marine piping. In short: nuclear-grade 90/10 cupronickel; tighter Fe/Mn than C70600; excellent seawater weldability.

What is the yield strength of C70620-HR50?

C70620-HR50 has a typical yield strength of 330 MPa (47.9 ksi) and a tensile strength of 400 MPa (58 ksi) — stronger than 69% of copper alloy grades. Strength varies by condition: see the 7 listed tempers.

Is C70620-HR50 easy to machine?

Not especially — machinability is rated fair (35/100, better than 51% of copper alloy grades). Gummy and work-hardening — rate ≈20 % of free-cutting brass; use sharp positive-rake carbide, moderate speed, heavy feed and generous coolant to avoid built-up edge.

Can C70620-HR50 be welded?

Yes — weldability is rated excellent (85/100). Designed for welding: GTAW/GMAW with C7158 (65/35 Cu-Ni) filler, no preheat, low interpass temperature, argon back-purge; keep joints oil- and sulphur-free to avoid hot cracking.

What surface finishes work on C70620-HR50?

Not anodizable; pickle in sulphuric/hydrogen-peroxide or inhibited nitric to remove weld oxide, then form the protective film with clean-water commissioning (or FeSO₄ dosing); takes a good mechanical or electro-polish.

Can C70620-HR50 be formed, bent or molded?

Excellent cold formability in O60 (deep drawing, U-bending, expansion); work-hardens fast, so interstage anneal at 700–850 °C with rapid cooling; hot work 850–950 °C.

What is the maximum service temperature of C70620-HR50?

C70620-HR50 is rated for continuous use to about 300°C (572 °F). Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

What is the difference between C70620-O60 and C70620-H08?

O60 is the default condition — standard condition for condenser/heat-exchanger tube, U-bends and cold-formed parts; maximum ductility and best corrosion consistency. H08: maximum cold-worked strength for springy strip, clips and diaphragms in marine/condensate environments. Yield strength is 120 MPa in O60 versus 485 MPa in H08.

Sources

  1. ASTM B466/B466M – Seamless Copper-Nickel Pipe and Tube — ASTM International (2020)
  2. ASTM B111/B111M – Copper and Copper-Alloy Seamless Condenser Tubes — ASTM International (2021)
  3. ASTM B171 / B402 – Cu-Ni plate and sheet for condensers — ASTM International (2018)
  4. CDA alloy datasheet C70600 / C70620 (UNS registration) — Copper Development Association (2023)
  5. ASM Handbook Vol. 2 — Properties of Copper and Copper Alloys — ASM International (1990)
  6. Copper-Nickel Alloys for Seawater Systems (technical guide) — Copper Development Association / Nickel Institute (2019)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.