FabDigitFabDigit

CPVC 4120 IMP (Impact-modified CPVC)

Grade

ASTM D1784 Cell Class 23447

Elevated acrylic/MBS modifier loading for cold-climate installation, thin-wall tube and drop-impact-critical parts.

Standard cost $$

Values for the IMP condition

Other CPVC 4120 grades and fills

CPVC 4120 is listed in 6 conditions; see the grade overview at CPVC 4120.

Compare all 6 grades and fillsHide
Grade · open for datasheetBest forYield MPaTensile MPaElong. %Hardness
IMPThis page
Impact-modified CPVC
Elevated acrylic/MBS modifier loading for cold-climate installation, thin-wall tube and drop-impact-critical parts.44484578 Shore D
Injection-molding fitting compound
Lower-viscosity 23447 compound for thick-wall socket fittings and valve bodies; slightly lower notched impact than extrusion grade.51541881 Shore D
Low smoke / plenum-rated flame-retardant compound
Use where UL 94 5VA and ASTM E84 25/50 flame-spread/smoke performance is mandated (plenum spaces, electrical duct).51542083 Shore D
UV-stabilized / outdoor-exposure compound
TiO₂-loaded, UV-stabilized version for exposed above-ground piping; still recommended to be painted with light-colored latex.52552482 Shore D
Industrial Schedule 80 pipe/duct compound
Higher-temperature industrial process piping, chemical drain and corrosive fume duct up to 93–100 °C.53562483 Shore D
20 % glass-fiber reinforced CPVC
Choose for rigid ducting, pump/valve components and supports needing higher stiffness, creep resistance and lower CTE.—75385 Shore D

What is CPVC 4120 IMP?

CPVC 4120 IMP is CPVC 4120 in the IMP grade — elevated acrylic/MBS modifier loading for cold-climate installation, thin-wall tube and drop-impact-critical parts. CPVC 4120 IMP has a yield strength of 44 MPa (6.38 ksi) and a tensile strength of 48 MPa (6.96 ksi) — weaker than 60% of polymer grades. Elongation at break is 45% and the elastic modulus is 2.7 GPa (0.392 Msi). CPVC 4120 IMP has a density of 1.53 g/cm³ (0.0553 lb/in³), heavier than 89% of polymer grades. Its glass-transition temperature is 120°C (248 °F).

Advantages

  • Tough — resists crack growth — 4.5 MPa·√m (4.1 ksi·√in), better than 96% of polymer grades
  • Low moisture uptake — 0.04%, better than 86% of polymer grades
  • Low embodied carbon — 2.9 kg CO₂/kg, better than 85% of polymer grades
  • Easy to machine — 72/100, better than 76% of polymer grades

Limitations

  • Heavy — 1.53 g/cm³ (0.0553 lb/in³), worse than 89% of polymer grades
  • Poor heat conductor — 0.15 W/m·K (0.0867 BTU/hr·ft·°F), worse than 80% of polymer grades

CPVC 4120 IMP properties

Typical room-temperature values for CPVC 4120 IMP; 25 are specific to this condition. Other listed values are CPVC 4120 reference data and may not represent this condition. Bars are the position among polymer grades.

Physical5

CPVC 4120 IMP has a density of 1.53 g/cm³ (0.0553 lb/in³), heavier than 89% of polymer grades. Its glass-transition temperature is 120°C (248 °F).

Density1.53 g/cm³0.06 lb/in³
Glass Transition (Tg)120°C248 °F
Water Absorption (24 h)0.04%
Water Absorption (Saturation)0.15%
Refractive Index1.53

Mechanical16

CPVC 4120 IMP has a yield strength of 44 MPa (6.38 ksi) and a tensile strength of 48 MPa (6.96 ksi) — weaker than 60% of polymer grades. Elongation at break is 45% and the elastic modulus is 2.7 GPa (0.392 Msi).

Elastic (Young's) Modulus2.7 GPa0.39 Msi
Shear Modulus1.1 GPa0.16 Msi
Bulk Modulus4 GPa0.61 Msi
Poisson's Ratio0.38
Tensile Strength (Ultimate)48 MPa7 ksi
Yield Strength (0.2% offset)44 MPa6.4 ksi
Elongation at Break45%
Compressive Strength57 MPa8.3 ksi
Compressive Modulus2.8 GPa0.41 Msi
Flexural Strength80 MPa11.6 ksi
Flexural Modulus2.6 GPa0.38 Msi
Shear Strength36 MPa5.2 ksi
Fracture Toughness (K_IC)4.5 MPa·√m4.1 ksi·√in
Izod Impact, Notched380 J/m7.1 ft·lbf/in
Hardness, Shore D78 Shore D
Hardness, Rockwell R112 HRR

Thermal11

CPVC 4120 IMP is rated for continuous service to 90°C (194 °F). It conducts heat at 0.15 W/m·K (0.0867 BTU/hr·ft·°F), worse than 80% of polymer grades. Thermal expansion is 65 µm/m·K (36.1 µin/in·°F).

Thermal Conductivity0.15 W/m·K0.09 BTU/hr·ft·°F
Specific Heat Capacity950 J/kg·K0.23 BTU/lb·°F
Thermal Expansion (CTE, 20–100 °C)65 µm/m·K36.1 µin/in·°F
Max Service Temperature (continuous)90°C194 °F
Min Service Temperature-30°C-22 °F
Heat Deflection Temp. @ 0.45 MPa112°C234 °F
Heat Deflection Temp. @ 1.8 MPa100°C212 °F
Vicat Softening Point (B50)108°C226 °F
Flammability (UL 94)V-0 at ≥1.5 mm; many pipe/fitting compounds also carry 5VB/5VA and 25/50 flame-spread/smoke ratings (ASTM E84)
Limiting Oxygen Index55%
Max Service Temperature (short-term)105°C221 °F

Electrical7

CPVC 4120 IMP is an electrical insulator with a dielectric strength of 22 kV/mm (558.8 V/mil) and a resistivity of 1×10¹³ Ω·m.

Electrical Resistivity1×10¹³ Ω·m3.94×10²⁰ µΩ·in
Dielectric Strength22 kV/mm559 V/mil
Dielectric Constant (1 MHz)3.3
Dissipation Factor (1 MHz)0.02
Volume Resistivity1×10¹⁵ Ω·cm
Surface Resistivity1×10¹⁴ Ω
Comparative Tracking Index (CTI)600 V

Chemical & Environmental3

Corrosion resistance is excellent (89/100), better than 77% of polymer grades. UV resistance is fair.

Corrosion ResistanceExcellent89/100
UV / Weathering ResistanceFair45/100
Chemical Resistance SummaryExcellent in dilute and concentrated mineral acids, alkalis, salt solutions, hypochlorite and chlorinated potable water to 90 °C; resistant to most oxidizers. Attacked/swollen by ketones (MEK, acetone), esters, chlorinated and aromatic solvents, THF, amines, and some phthalate-plasticized materials; avoid contact with ammonia-based thread sealants, cutting oils and plasticized vinyl tape.

Sustainability4

Producing a kilogram of CPVC 4120 IMP takes about 72 MJ of energy and emits 2.9 kg of CO₂ — less than 93% of polymer grades. Typical recycled content is 2%.

Embodied Energy (primary production)72 MJ/kg30,954 BTU/lb
Embodied Carbon (primary production)2.9 kg CO₂/kg
Embodied Water180 L/kg21.6 gal/lb
Typical Recycled Content2%

Manufacturability7

CPVC 4120 IMP's machinability is very good (72/100, better than 76% of polymer grades); weldability fair (50/100); formability fair (45/100).

MachinabilityVery good72/100
WeldabilityFair50/100
Formability (cold)Fair45/100
PolishabilityFair50/100
Mold Shrinkage0.5%
Processing Melt Temperature (typ.)200°C392 °F
Mold Temperature (typ.)50°C122 °F

Values are nominal handbook figures for design screening. Confirm any required mill or lot documentation when quoting.

Working with CPVC 4120 IMP

Is CPVC 4120 easy to machine?

Machines easily with sharp, high-rake carbide or HSS tools at moderate speed and generous chip clearance; use air or water-soluble coolant (no petroleum cutting oils) and avoid frictional heat that causes local degradation/HCl release.

Can CPVC 4120 be welded?

Joined mainly by two-step CPVC primer + solvent cement (ASTM F493) or threaded/flanged connections; hot-gas and hot-plate welding with CPVC rod work for sheet/duct but never use PVC cement or PVC rod.

Can CPVC 4120 be formed, bent or molded?

Extrude/mold at 185–215 °C melt with corrosion-resistant (Hastelloy/nitrided) screws and dies, no dead spots, and purge with PE at shutdown; sheet thermoforms at 130–155 °C, cold bending is not recommended.

What surface finishes work on CPVC 4120?

Solvent-wipe and paint with light-colored acrylic/latex for outdoor UV protection; can be printed, ultrasonically inserted or mechanically fastened — do not use plasticized vinyl tape, ammonia-based sealants or aggressive solvent cleaners on the surface.

CPVC 4120 chemical composition (wt %)

Limits by weight percent from the governing specification, written the way the spec states them — a single maximum for impurities, a range for alloying elements, and the base element as balance. Nominal is the typical mid-range value.

ElementSpec limit (wt %)Nominal
impact modifier (acrylic / MBS / CPE)sets Izod cell digit3 – 96
organotin heat stabilizermethyl/butyl tin mercaptide; potable-water compliant1.5 – 3.52.5
lubricants (oxidized PE, paraffin wax, cinternal + external lubrication for fusion control1 – 32
processing aid (acrylic)0.5 – 21
titanium dioxide / pigmenttan (CTS), orange (sprinkler), gray (Sch 80)1 – 52
antimony trioxide / smoke suppressant (oonly in 5VA / low-smoke variants0 – 30
CPVC resin (chlorinated poly(vinyl chlorbase resin per ASTM D1784 cell 2 (CPVC)≥ 80 (balance)—

CPVC 4120 IMP — frequently asked

What is CPVC 4120 IMP used for?

CPVC 4120 IMP is typically used for hot & cold water piping, fire sprinkler systems and industrial process piping. In short: hot-water rated rigid vinyl; 93 °C service temperature; sprinkler-listed piping compound.

What is the yield strength of CPVC 4120 IMP?

CPVC 4120 IMP has a typical yield strength of 44 MPa (6.38 ksi) and a tensile strength of 48 MPa (6.96 ksi) — weaker than 60% of polymer grades. Strength varies by condition: see the 6 listed tempers.

Is CPVC 4120 IMP easy to machine?

Yes — machinability is rated very good (72/100, better than 76% of polymer grades). Machines easily with sharp, high-rake carbide or HSS tools at moderate speed and generous chip clearance; use air or water-soluble coolant (no petroleum cutting oils) and avoid frictional heat that causes local degradation/HCl release.

Can CPVC 4120 IMP be welded?

With care — weldability is rated fair (50/100). Joined mainly by two-step CPVC primer + solvent cement (ASTM F493) or threaded/flanged connections; hot-gas and hot-plate welding with CPVC rod work for sheet/duct but never use PVC cement or PVC rod.

What surface finishes work on CPVC 4120 IMP?

Solvent-wipe and paint with light-colored acrylic/latex for outdoor UV protection; can be printed, ultrasonically inserted or mechanically fastened — do not use plasticized vinyl tape, ammonia-based sealants or aggressive solvent cleaners on the surface.

Can CPVC 4120 IMP be formed, bent or molded?

Extrude/mold at 185–215 °C melt with corrosion-resistant (Hastelloy/nitrided) screws and dies, no dead spots, and purge with PE at shutdown; sheet thermoforms at 130–155 °C, cold bending is not recommended.

What is the maximum service temperature of CPVC 4120 IMP?

CPVC 4120 IMP is rated for continuous use to about 90°C (194 °F), and briefly to 105°C. Strength falls off well before that limit — check the elevated-temperature data for load-bearing parts.

Sources

  1. ASTM D1784 — Rigid PVC and CPVC Compounds (cell classification) — ASTM International (2020)
  2. ASTM D2846 / F441 / F442 — CPVC CTS and Schedule 40/80 pipe and tubing — ASTM International (2021)
  3. NSF/ANSI 61 & 14 — Drinking Water System Components / Plastic Piping System Components — NSF International (2023)
  4. TempRite CPVC pipe and fittings compound property data — Lubrizol Advanced Materials (2023)
  5. Engineered Materials Handbook Vol. 2: Engineering Plastics — ASM International (1988)
  6. PPI TR-21 Thermal Expansion and Contraction of Plastic Pipe — Plastics Pipe Institute (2019)

Property data is compiled from published supplier and standards handbooks and normalised for comparison. Nothing on this page is a certification — request mill certs, CoC or material test reports with your order.